41 resultados para UGC platform

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

First demonstration of a working dynamically configurable architecture for wireless IP networks. The programmable architecture was as result of a European collaboration between Industry and University and was applied to a range of IP wireless networks. The work laid the foundations for subsequent research initiatives (including the UK) into programmable wireless networks as well as influencing future wireless standards (e.g. ITU-T).EU project WINE (Wireless Internet NEtworking), -1999-10028.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple approach to sensor development based on encapsulating a probe molecule in a cellulose support followed by regeneration from an ionic liquid solution is demonstrated here by the codissolution of cellulose and 1-(2-pyridylazo)-2-naphthol in 1-butyl-3-methylimidazolium chloride followed by regeneration with water to form strips which exhibit a proportionate (1 : 1) response to Hg(II) in aqueous solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extensive light and colour curves for the Type Ia supernova (SN Ia) SN 2002er are presented as part of the European Supernova Collaboration. We have collected UBVRI photometry from 11 different telescopes covering the phases from 7 d before until 619 d after maximum light. Corrections for the different instrumental systems and the non-thermal spectrum of the supernova (S-corrections) have been applied. With the densely sampled light curves we can make detailed comparisons to other well-observed objects. SN 2002er most closely resembles SN 1996X after maximum, but clearly shows a different colour evolution before peak light and a stronger shoulder in V and R bands compared to other well-observed SNe Ia. In particular, the rise time appears to be longer than what is expected from the rise time versus decline rate relation. We use several methods to determine the reddening towards SN 2002er based on the colour evolution at near peak and at late phases. The uvoir (bolometric) light curve shows great similarity with SN 1996X, but also indications of a higher luminosity, longer rise time and a more pronounced shoulder 25 d past maximum. The interpretation of the light curves was carried out with two independent light curve codes. Both find that given the luminosity of SN 2002er the Ni-56 mass exceeds 0.6 M-circle dot with preferred values near 0.7 M-circle dot. Uncertainties in the exact distance to SN 2002er are the most serious limitation of this measurement. The light-curve modelling also indicates a high level of mixing of the nickel in the explosion of SN 2002er.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Digital pathology provides a digital environment for the management and interpretation of pathological images and associated data. It is becoming increasing popular to use modern computer based tools and applications in pathological education, tissue based research and clinical diagnosis. Uptake of this new technology is stymied by its single user orientation and its prerequisite and cumbersome combination of mouse and keyboard for navigation and annotation.

Methodology: In this study we developed SurfaceSlide, a dedicated viewing platform which enables the navigation and annotation of gigapixel digitised pathological images using fingertip touch. SurfaceSlide was developed using the Microsoft Surface, a 30 inch multitouch tabletop computing platform. SurfaceSlide users can perform direct panning and zooming operations on digitised slide images. These images are downloaded onto the Microsoft Surface platform from a remote server on-demand. Users can also draw annotations and key in texts using an on-screen virtual keyboard. We also developed a smart caching protocol which caches the surrounding regions of a field of view in multi-resolutions thus providing a smooth and vivid user experience and reducing the delay for image downloading from the internet. We compared the usability of SurfaceSlide against Aperio ImageScope and PathXL online viewer.

Conclusion: SurfaceSlide is intuitive, fast and easy to use. SurfaceSlide represents the most direct, effective and intimate human–digital slide interaction experience. It is expected that SurfaceSlide will significantly enhance digital pathology tools and applications in education and clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1,3-propanediol was subjected to a range of amination conditions. The N-heterocyclic carbene piano stool complex [Cp*IrCl2(bmim)] was found to be a good catalyst for amination and dehydration in toluene or ionic liquid; product compositions could be tuned by altering the ratio of diol to amine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, there are no fast in vitro broad spectrum screening bioassays for the detection of marine toxins. The aim of this study was to develop such an assay. In gene expression profiling experiments 17 marker genes were provisionally selected that were differentially regulated in human intestinal Caco-2 cells upon exposure to the lipophilic shellfish poisons azaspiracid-1 (AZA1) or dinophysis toxin-1 (DTX1). These 17 genes together with two control genes were the basis for the design of a tailored microarray platform for the detection of these marine toxins and potentially others. Five out of the 17 selected marker genes on this dedicated DNA microarray gave dear signals, whereby the resulting fingerprints could be used to detect these toxins. CEACAM1, DDIT4, and TUBB3 were up-regulated by both AZA1 and DTX1, TRIB3 was up-regulated by AZA1 only, and OSR2 by DTX1 only. Analysis by singleplex qRT-PCR revealed the up- and down-regulation of the selected RGS16 and NPPB marker genes by DTX1, that were not envisioned by the new developed dedicated array. The qRT-PCR targeting the DDIT4, RSG16 and NPPB genes thus already resulted in a specific pattern for AZA1 and DTX1 indicating that for this specific case qRT-PCR might a be more suitable approach than a dedicated array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OpenPMU is an open platform for the development of phasor measurement unit (PMU) technology. A need has been identified for an open-source alternative to commercial PMU devices tailored to the needs of the university researcher and for enabling the development of new synchrophasor instruments from this foundation. OpenPMU achieves this through open-source hardware design specifications and software source code, allowing duplicates of the OpenPMU to be fabricated under open-source licenses. This paper presents the OpenPMU device based on the Labview development environment. The device is performance tested according to the IEEE C37.118.1 standard. Compatibility with the IEEE C37.118.2 messaging format is achieved through middleware which is readily adaptable to other PMU projects or applications. Improvements have been made to the original design to increase its flexibility. A new modularized architecture for the OpenPMU is presented using an open messaging format which the authors propose is adopted as a platform for PMU research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To develop real-time simulations of wind instruments, digital waveguides filters can be used as an efficient representation of the air column. Many aerophones are shaped as horns which can be approximated using conical sections. Therefore the derivation of conical waveguide filters is of special interest. When these filters are used in combination with a generalized reed excitation, several classes of wind instruments can be simulated. In this paper we present the methods for transforming a continuous description of conical tube segments to a discrete filter representation. The coupling of the reed model with the conical waveguide and a simplified model of the termination at the open end are described in the same way. It turns out that the complete lossless conical waveguide requires only one type of filter.Furthermore, we developed a digital reed excitation model, which is purely based on numerical integration methods, i.e., without the use of a look-up table.