20 resultados para Test reliability

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Despite the popularity of the Theory of Planned Behaviour (TPB) a lack of research assessing the efficacy of the model in understanding the health behaviour of children exists, with those studies that have been conducted reporting problems with questionnaire formulation and low to moderate internal consistencies for TPB constructs. The aim of this study was to develop and test a TPB-based measure suitable for use with primary school children aged 9 to 10 years. A mixed method sequential design was employed. In Stage 1, 7 semi-structured focus group discussions (N=56) were conducted to elicit the underlying beliefs specific to tooth brushing. Using content thematic analysis the beliefs were identified and a TPB measure was developed. A repeated measures design was employed in Stage 2 using test re-test reliability analysis in order to assess its psychometric properties. In all, 184 children completed the questionnaire. Test-retest reliabilities support the validity and reliability of the TPB measure for assessing the tooth brushing beliefs of children. Pearson’s product moment correlations were calculated for all of the TPB beliefs, achieving substantial to almost perfect agreement levels. Specifically, a significant relationship between all 10 of the direct and indirect TPB constructs at the 0.01 level was achieved. This paper will discuss the design and development of the measure so could serve as a guide to fellow researchers and health psychologists interested in using theoretical models to investigate the health and well-being of children.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the reliability and thus the suitability of optical fibre strain sensors for surface strain measurement in concrete structures was investigated. Two different configurations of optical strain sensors were used each having different mountings making them suitable for different uses in various structures. Due to the very limited time available to install the sensors and take result, commercially packaged sensors were used. In the tests carried out each sensor was mounted onto a concrete beam which was then subjected to a range of known and calibrated loadings. The performance of the optical strain sensors thus evaluated was compared with the results of conventional techniques. This comparison allows for selecting the best performing combination of sensor/mounting, i.e. long-gauge sensor with mounts bolted to threaded rods glued into the concrete for use in future work in a field test where a limited time window was available for installation, testing and post-test demounting. © 2012 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this experiment was to assess the test-retest reliability of input-output parameters of the cortico-spinal pathway derived from transcranial magnetic (TMS) and electrical (TES) stimulation at rest and during muscle contraction. Motor evoked potentials (MEPs) were recorded from the first dorsal interosseous muscle of eight individuals on three separate days. The intensity of TMS at rest was varied from 5% below threshold to the maximal output of the stimulator. During trials in which the muscle was active, TMS and TES intensities were selected that elicited MEPs of between 150 and 300 X at rest. MEPs were evoked while the participants exerted torques up to 50% of their maximum capacity. The relationship between MEP size and stimulus intensity at rest was sigmoidal (R-2 = 0.97). Intra-class correlation coefficients (ICC) ranged between 0.47 and 0.81 for the parameters of the sigmoid function. For the active trials, the slope and intercept of regression equations of MEP size on level of background contraction were obtained more reliably for TES (ICC = 0.63 and 0.78, respectively) than for TMS (ICC = 0.50 and 0.53, respectively), These results suggest that input-output parameters of the cortico-spinal pathway may be reliably obtained via transcranial stimulation during longitudinal investigations of cortico-spinal plasticity. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The LifeShirt is a novel ambulatory monitoring system that records cardio respiratory measurements outside the laboratory. Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt were assessed and two methods of calibrating the LifeShirt were compared. Participants performed an incremental treadmill test and a constant work rate test (65% peak oxygen uptake) on four occasions (>48 In apart) and wore the LifeShirt, COSMED system and Polar Sport Tester simultaneously. The LifeShirt was calibrated using two methods: comparison to a spirometer; and 800 ml fixed-volume bag. Ventilation, respiratory rate, expiratory time and heart rate recorded by the LifeShirt were compared to measurements recorded by laboratory equipment. Sixteen adults participated (6M: 10F); mean (SD) age 23.1 (2.9) years. Agreement between the LifeShirt and laboratory equipment was acceptable. Agreement for ventilation was improved by calibrating the LifeShirt using a spirometer. Reliability was similar for the LifeShirt and the laboratory equipment. This study suggests that the LifeShirt provides a valid and reliable method of ambulatory monitoring. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The blood pressure waveform is modified on distal propagation by phenomena such as dispersion, reflection and the state of the arterial compliance. The consequent effects are amplification and narrowing of the wave, with an increased systolic, reduced diastolic and essentially unaltered mean blood pressure. The Finapres measures the peripheral pressure using the volume clamp principle; it has not been validated under altered physiological conditions and during pharmacodynamic interventions. We studied simultaneous Finapres and brachial blood pressures (using a conventional oscillometric sphygmomanometer—Vitalmap) in ten normal volunteers at rest, and during dynamic exercise and a cold pressor test. The effects of pharmacodynamic intervention were examined following beta-adrenoceptor blockade with propranolol (160 mg) or beta-adrenoceptor modulation with the beta-adrenoceptor partial agonist celiprolol (400 mg). The Finapres systolic pressure was significantly higher than the brachial value during all three test states. The difference between the systolic pressures measured by the two devices was shown to increase significantly during the cold pressor test, but not during dynamic (supine bicycle) exercise. The Finapres diastolic pressure was significantly higher than the Vitalmap value during exercise and the cold pressor test. The differences between the two methods increased significantly over time. Beta-adrenergic blockade with propranolol or modulation with celiprolol had no significant interaction with the pressure differences between the Finapres and Vitalmap techniques. The results would support the view that the Finapres can provide blood pressure information which is robust under most circumstances. Although this pharmacodynamic intervention did not alter the relationship between the peripheral and central blood pressure, it is important to note that this dynamic relationship is sensitive to circulatory loading conditions and wave transmission characteristics; it is possible that the Finapres could be less reliable in clinical settings where potent vasoactive agents were being administered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concurrent validity of a 1 minute walk test at a child's maximum walking speed was assessed in children with bilateral spastic cerebral palsy (BSCP). The distance covered during the 1 minute walk test was compared with the children's gross motor function as assessed by the Gross Motor Function Measure (GMFM). Twenty-four male and 10 female children with CP (mean age 11y, range 4 to 16y) participated in the study. Gross Motor Function Classification System (GMFCS) levels were; level I (n=3), level II (n=17), level III (n=10), and level IV (n=4). Participants had clinical diagnoses of symmetrical diplegia (n=19), asymmetrical diplegia (n=14), and quadriplegia (n=1). Results showed a significant correlation between GMFM score and the distance covered during the 1 minute walk (r=0.92; p<0.001). There was also a significant decrease in the distance walked with increasing GMFCS level (p<0.001). We concluded that the 1 minute walk test is a valid measure for assessing functional ability in children with ambulatory BSCP. Its cost-effectiveness and user friendliness make it a potentially useful tool in the clinical setting. Further study needs to address its reliability and ability to detect change over time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Given that the ability to manage numbers is essential in a modern society, mathematics anxiety – which has been demonstrated to have unfortunate consequences in terms of mastery of math – has become a subject of increasing interest, and the need to accurately measure it has arisen. One of the widely employed scales to measure math anxiety is the Abbreviated Math Anxiety Scale (AMAS) (Hopko, Mahadevan, Bare & Hunt, 2003). The first aim of the present paper was to confirm the factor structure of the AMAS when administered to Italian high school and college students, and to test the invariance of the scale across educational levels. Additionally, we assessed the reliability and validity of the Italian version of the scale. Finally, we tested the invariance of the AMAS across genders. The overall findings provide evidence for the validity and reliability of the AMAS when administered to Italian students.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper the tracking system used to perform a scaled vehicle-barrier crash test is reported. The scaled crash test was performed as part of a wider project aimed at designing a new safety barrier making use of natural building materials. The scaled crash test was designed and performed as a proof of concept of the new mass-based safety barriers and the study was composed of two parts: the scaling technique and of a series of performed scaled crash tests. The scaling method was used for 1) setting the scaled test impact velocity so that energy dissipation and momentum transferring, from the car to the barrier, can be reproduced and 2) predicting the acceleration, velocity and displacement values occurring in the full-scale impact from the results obtained in a scaled test. To achieve this goal the vehicle and barrier displacements were to be recorded together with the vehicle accelerations and angular velocities. These quantities were measured during the tests using acceleration sensors and a tracking system. The tracking system was composed of a high speed camera and a set of targets to measure the vehicle linear and angular velocities. A code was developed to extract the target velocities from the videos and the velocities obtained were then compared with those obtained integrating the accelerations provided by the sensors to check the reliability of the method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A reliable and valid instrument is needed to screen for depression in palliative patients. The interRAI Depression Rating Scale (DRS) is based on seven items in the interRAI Palliative Care instrument. This study is the first to explore the dimensionality, reliability and validity of the DRS in a palliative population. Palliative home care patients (n = 5,175) residing in Ontario (Canada) were assessed with the interRAI Palliative Care instrument. Exploratory factor analysis and Mokken scale analysis were used to identify candidate conceptual models and evaluate scale homogeneity/performance. Confirmatory factor analysis compared models using standard goodness-of-fit indices. Convergent and divergent validity were investigated by examining polychoric correlations between the DRS and other items. The “known groups” test determined if the DRS meaningfully distinguished among client subgroups. The non-hierarchical two factor model showed acceptable fit with the data, and ordinal alpha coefficients of 0.83 and 0.82 were observed for the two DRS subscales. Omega hierarchical (ωh) was 0.78 for the bifactor model, with the general factor explaining three quarters of the common variance. Despite the multidimensionality evident in the factor analyses, bifactor modelling and the Mokken homogeneity coefficient (0.34) suggest that the DRS is a coherent scale that captures important information on sub-constructs of depression (e.g., somatic symptoms). Higher correlations were seen between the DRS and mood and psychosocial well-being items, and lower correlations with functional status and demographic variables. The DRS distinguished in the expected manner for known risk factors (e.g., social support, pain). The results suggest that the DRS is primarily unidimensional and reliable for use in screening for depression in palliative care patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a continuous time Markov chain (CTMC) based sequential analytical approach for composite generation and transmission systems reliability assessment. The basic idea is to construct a CTMC model for the composite system. Based on this model, sequential analyses are performed. Various kinds of reliability indices can be obtained, including expectation, variance, frequency, duration and probability distribution. In order to reduce the dimension of the state space, traditional CTMC modeling approach is modified by merging all high order contingencies into a single state, which can be calculated by Monte Carlo simulation (MCS). Then a state mergence technique is developed to integrate all normal states to further reduce the dimension of the CTMC model. Moreover, a time discretization method is presented for the CTMC model calculation. Case studies are performed on the RBTS and a modified IEEE 300-bus test system. The results indicate that sequential reliability assessment can be performed by the proposed approach. Comparing with the traditional sequential Monte Carlo simulation method, the proposed method is more efficient, especially in small scale or very reliable power systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the increasing utilization of electric vehicles (EVs), transportation systems and electrical power systems are becoming increasingly coupled. However, the interaction between these two kinds of systems are not well captured, especially from the perspective of transportation systems. This paper studies the reliability of integrated transportation and electrical power system (ITES). A bidirectional EV charging control strategy is first demonstrated to model the interaction between the two systems. Thereafter, a simplified transportation system model is developed, whose high efficiency makes the reliability assessment of the ITES realizable with an acceptable accuracy. Novel transportation system reliability indices are then defined from the view point of EV’s driver. Based on the charging control model and the transportation simulation method, a daily periodic quasi sequential reliability assessment method is proposed for the ITES system. Case studies based on RBTS system demonstrate that bidirectional charging controls of EVs will benefit the reliability of power systems, while decrease the reliability of EVs travelling. Also, the optimal control strategy can be obtained based on the proposed method. Finally, case studies are performed based on a large scale test system to verify the practicability of the proposed method.