67 resultados para TIME-DOMAIN TECHNIQUE

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methods of measuring the acoustic behavior of tubular systems can be broadly characterized as steady state measurements, where the measured signals are analyzed in terms of infinite duration sinusoids, and reflectometry measurements which exploit causality to separate the forward and backward going waves in a duct. This paper sets out a multiple microphone reflectometry technique which performs wave separation by using time domain convolution to track the forward and backward going waves in a cylindrical source tube. The current work uses two calibration runs (one for forward going waves and one for backward going waves) to measure the time domain transfer functions for each pair of microphones. These time domain transfer functions encode the time delay, frequency dependent losses and microphone gain ratios for travel between microphones. This approach is applied to the measurement of wave separation, bore profile and input impedance. The work differs from existing frequency domain methods in that it combines the information of multiple microphones within a time domain algorithm, and differs from existing time domain methods in its inclusion of the effect of losses and gain ratios in intermicrophone transfer functions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a method for modeling diffusion caused by non-smooth boundary surfaces in simulations of room acoustics using finite difference time domain (FDTD) technique is investigated. The proposed approach adopts the well-known theory of phase grating diffusers to efficiently model sound scattering from rough surfaces. The variation of diffuser well-depths is attained by nesting allpass filters within the reflection filters from which the digital impedance filters used in the boundary implementation are obtained. The presented technique is appropriate for modeling diffusion at high frequencies caused by small surface roughness and generally diffusers that have narrow wells and infinitely thin separators. The diffusion coefficient was measured with numerical experiments for a range of fractional Brownian diffusers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Modeling of on-body propagation channels is of paramount importance to those wishing to evaluate radio channel performance for wearable devices in body area networks (BANs). Difficulties in modeling arise due to the highly variable channel conditions related to changes in the user's state and local environment. This study characterizes these influences by using time-series analysis to examine and model signal characteristics for on-body radio channels in user stationary and mobile scenarios in four different locations: anechoic chamber, open office area, hallway, and outdoor environment. Autocorrelation and cross-correlation functions are reported and shown to be dependent on body state and surroundings. Autoregressive (AR) transfer functions are used to perform time-series analysis and develop models for fading in various on-body links. Due to the non-Gaussian nature of the logarithmically transformed observed signal envelope in the majority of mobile user states, a simple method for reproducing the failing based on lognormal and Nakagami statistics is proposed. The validity of the AR models is evaluated using hypothesis testing, which is based on the Ljung-Box statistic, and the estimated distributional parameters of the simulator output compared with those from experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents the results from an experimental program designed to evaluate the performance of a system consisting of a readout unit and a ribbon type Fiber Optic Sensor (FOS) based on Brillouin Optical Time Domain Analysis (BOTDA). The system is intended for the detection of cracks as well as the monitoring of long-term performance for steel bridge girders. The program consisted of introducing a crack at the center of a 3-m-long steel beam and monitoring its progression using static loading tests performed at ambient and sub-zero temperatures. For sensor lengths similar to those used in the field, the resonant frequency shifts per unit increase in crack width were found to decrease from 114 MHz/mm at ambient temperature (~25C) to 65 MHz/mm at -10C. Results also revealed nonlinearity and variability, which can be attributed to an incompatibility between the settings of the laser pump in the readout unit and the sensor length. Significant losses were detected along the bonded segments of the sensor and were attributed to the presence of ripples along the sensor. These undulations worsen with a reduction in temperature and are induced by the bonding procedure as well as the slack provided in the plastic sleeves containing the splices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare time-domain waveform analysis of second-trimester uterine artery Doppler using the resistance index (RI) with waveform analysis using a mathematical tool known as wavelet transform for the prediction of pre-eclampsia (PE). This was a retrospective, nested case-cohort study of 336 women, 37 of whom subsequently developed PE. Uterine artery Doppler waveforms were analysed using both RI and waveform analysis. The utility of these indices in screening for PE was then evaluated using receiver operating characteristic curves. There were significant differences in uterine artery RI between the PE women and those with normal pregnancy outcome. After wavelet analysis, significant difference in the mean amplitude in wavelet frequency band 4 was noted between the 2 groups. The sensitivity for both Doppler RI and frequency band 4 for the detection of PE at a 10% false-positive rate was 45%. This small study demonstrates the application of wavelet transform analysis of uterine artery Doppler waveforms in screening for PE. Further prospective studies are needed in order to clearly define if this analytical approach to waveform analysis may have the potential to improve the detection of PE by uterine artery Doppler screening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The finite difference time domain (FDTD) method has direct applications in musical instrument modeling, simulation of environmental acoustics, room acoustics and sound reproduction paradigms, all of which benefit from auralization. However, rendering binaural impulse responses from simulated
data is not straightforward to accomplish as the calculated pressure at FDTD grid nodes does not contain any directional information. This paper addresses this issue by introducing a spherical array to capture sound pressure on a finite difference grid, and decomposing it into a plane-wave density
function. Binaural impulse responses are then constructed in the spherical harmonics domain by combining the decomposed grid data with free field head-related transfer functions. The effects of designing a spherical array in a Cartesian grid are studied, and emphasis is given to the relationships
between array sampling and the spatial and spectral design parameters of several finite-difference
schemes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a mixed cost-function adaptive initialization algorithm for the time domain equalizer in a discrete multitone (DMT)-based asymmetric digital subscriber line. Using our approach, a higher convergence rate than that of the commonly used least-mean square algorithm is obtained, whilst attaining bit rates close to the optimum maximum shortening SNR and the upper bound SNR. Furthermore, our proposed method outperforms the minimum mean-squared error design for a range of time domain equalizer (TEQ) filter lengths. The improved performance outweighs the small increase in computational complexity required. A block variant of our proposed algorithm is also presented to overcome the increased latency imposed on the feedback path of the adaptive system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tanpura string vibrations have been investigated previously using numerical models based on energy conserving schemes derived from a Hamiltonian description in one-dimensional form. Such time-domain models have the property that, for the lossless case, the numerical Hamiltonian (representing total energy of the system) can be proven to be constant from one time step
to the next, irrespective of any of the system parameters; in practice the Hamiltonian can be shown to be conserved within machine precision. Models of this kind can reproduce a jvari effect, which results from the bridge-string interaction. However the one-dimensional formulation has recently been shown to fail to replicate the jvaris strong dependence on the thread placement. As a first step towards simulations which accurately emulate this sensitivity to the thread placement, a twodimensional model is proposed, incorporating coupling of controllable level between the two string polarisations at the string termination opposite from the barrier. In addition, a friction force acting when the string slides across the bridge in horizontal direction is introduced, thus effecting a further damping mechanism. In this preliminary study, the string is terminated at the position of the thread. As in the one-dimensional model, an implicit scheme has to be used to solve the system, employing Newton's method to calculate the updated positions and momentums of each string segment. The two-dimensional model is proven to be energy conserving when the loss parameters are set to zero, irrespective of the coupling constant. Both frequency-dependent and independent losses are then added to the string, so that the model can be compared to analogous instruments. The influence of coupling and the bridge friction are investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vibrational Raman spectroscopy is now widely recognized as a useful technique for chemical analysis. It has become increasingly popular for the characterization of stable species since the technology which underpins Raman measurements has matured. Time-resolved Raman spectroscopy has also become established as an excellent method for the characterization of transient chemical species but it is not so widely applied. However, the technical advances which have reduced the cost and increased the reliability of conventional: Raman systems can also be exploited in studies of transient species. In some cases it is just as straightforward to record the Raman-spectra of a short-lived transient species as it is to monitor a more stable sample. This raises the possibility of routinely adding time-domain Raman measurements to more conventional Raman techniques, increasing the selectivity of the analysis while retaining its ability to provide spectral information which is characteristic of the species under investigation.