6 resultados para Sports - Safety measures

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent years unmanned vehicles have grown in popularity, with an ever increasing number of applications in industry, the military and research within air, ground and marine domains. In particular, the challenges posed by unmanned marine vehicles in order to increase the level of autonomy include automatic obstacle avoidance and conformance with the Rules of the Road when navigating in the presence of other maritime traffic. The USV Master Plan which has been established for the US Navy outlines a list of objectives for improving autonomy in order to increase mission diversity and reduce the amount of supervisory intervention. This paper addresses the specific development needs based on notable research carried out to date, primarily with regard to navigation, guidance, control and motion planning. The integration of the International Regulations for Avoiding Collisions at Sea within the obstacle avoidance protocols seeks to prevent maritime accidents attributed to human error. The addition of these critical safety measures may be key to a future growth in demand for USVs, as they serve to pave the way for establishing legal policies for unmanned vessels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the safety and effect on clinical outcomes and biomarkers of inflammation and tissue damage of the neutrophil elastase inhibitor AZD9668 (60 mg twice daily orally for 4 weeks) in cystic fibrosis. This was a randomised, double-blind, placebo-controlled study. Primary outcome measures were sputum neutrophil count, lung function, 24-h sputum weight, BronkoTest® diary card data and health-related quality-of-life (revised cystic fibrosis quality-of-life questionnaire). Secondary end-points included sputum neutrophil elastase activity, inflammatory biomarkers in sputum and blood, urine and plasma desmosine (an elastin degradation marker), AZD9668 levels and safety parameters (adverse events, routine haematology, biochemistry, electrocardiogram and sputum bacteriology). 56 patients were randomised, of which 27 received AZD9668. There was no effect for AZD9668 on sputum neutrophil counts, neutrophil elastase activity, lung function or clinical outcomes, including quality of life. In the AZD9668 group, there was a trend towards reduction in sputum inflammatory biomarkers with statistically significant changes in interleukin-6, RANTES and urinary desmosine. The pattern of adverse events was similar between groups. Consistent reductions in sputum inflammatory biomarkers were seen in the AZD9668 group, and reduction in urinary desmosine suggests that AZD9668 impacts elastin cleavage by neutrophil elastase.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate "in vivo" safety of trypan blue (TB) in patients undergoing TB-assisted internal limiting membrane or epiretinal membrane peeling. Methods: Prospective study including 21 patients (21 eyes) with full-thickness macular hole and/or epiretinal membrane undergoing TB-assisted internal limiting membrane/epiretinal membrane peeling. Main outcome measures included distance visual acuity, near visual acuity, amplitude of P50 and N95 of the pattern electroretinogram, and fundus autofluorescence; these were assessed preoperatively, at 6 months (n = 21) and 12 months (n = 10) postoperatively. Results: There was a statistically significant improvement in distance visual acuity, near visual acuity, P50, and N95 amplitude at 6 months and 12 months postoperatively. The mean logarithm of the minimum angle of resolution distance visual acuity and near visual acuity improved from baseline by 0.31 (SD 0.37) and 0.17 (SD 0.31) at 6 months, respectively, and by 0.4 (SD 0.25) and 0.35 (SD 0.28) at 12 months, respectively. The mean P50 and N95 component amplitudes improved by 28% compared with baseline at 6 months (P50 0.4 [SD 0.8]; N95 0.53 [SD 1.07]) and by 63% at 12 months (P50 0.9 [0.85]; N95 1.04 [1.34]). Autofluorescence did not demonstrate damage to the retinal pigment epithelium attributable to TB. Conclusion: No deleterious effects of TB were observed in this study. Copyright © 2011 Lippincott Williams &Wilkins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To evaluate the efficacy and safety of intraoperative mitomycin C (MMC) in eyes undergoing Ahmed Glaucoma Valve implantation. Design Randomized controlled clinical trial. Participants Sixty patients with refractory glaucoma. Intervention Sixty eyes of 60 patients with refractory glaucoma were randomized to receive intraoperative MMC (0.5 mg/ml for 5 minutes) (n = 34) or balanced salt solution (n = 26) during Ahmed Glaucoma Valve implantation. Main outcome measures Surgical success was defined according to 2 different criteria: (1) postoperative intraocular pressure (IOP) between 6 and 21 mmHg, with or without antiglaucoma medications, and (2) IOP reduction of at least 30% relative to preoperative values. Eyes requiring additional glaucoma surgery, developing phthisis, or showing loss of light perception were classified as failures. Success rates in both groups were compared using Kaplan-Meier survival curves and the log rank test. Other outcome measures were mean IOP, number of glaucoma medications, and complications. Results After a mean follow-up of 12.3 months, Kaplan-Meier survival analysis showed a probability of success of 59% at 18 months for the MMC group and 61% for the control group when the first criterion for success was used (IOP between 6 and 21 mmHg). When an IOP reduction of at least 30% was used as the criterion to define success, the Kaplan-Meier survival analysis demonstrated a probability of success at 18 months of 62% for the MMC group and 67% for the control group. There were no significant differences in survival rates between the 2 groups with either criterion (P = 0.75 and P = 0.37, respectively). After 15 days postoperatively, the mean IOP did not significantly differ for both MMC and control eyes. Mean numbers of postoperative antiglaucoma medications were similar in MMC-treated eyes and controls. There was no significant difference between the incidences of postoperative complications in both groups. Conclusion Mitomycin C did not increase the short- or intermediate-term success rates of Ahmed Glaucoma Valve implantation. © 2004 by the American Academy of Ophthalmology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In clinical trials the selection of appropriate outcomes is crucial to the assessment of whether one intervention is better than another. Glaucoma is a chronic eye disease and the leading cause of irreversible blindness in the world. A variety of outcomes has been used and reported in glaucoma RCTs.

Objectives: The purpose of this review is to identify different clinical outcome measures used in glaucoma RCTs between January 2006 and March 2012.

Methods: A systematic review was conducted using standard methodology. We searched for RCTs in glaucoma published in English with no restrictions on the population type or size, or applied interventions. All clinical outcomes were included. Patient-reported, pharmacokinetic and economic outcomes were excluded.

Results: The search strategy identified 4288 potentially relevant abstracts. There were 315 publications retrieved, of which 233 RCTs were included. A total of 967 clinical measures were reported. There were large variations in the definitions used to describe different outcomes and their measures. Intraocular pressure (IOP) was the most commonly reported outcome (used in 201 RCTs, 86%) with a total of 422 measures (44%). Amongst the IOPrelated measures, the most commonly used was mean IOP (n=143, 15% of all measures). Safety outcomes were commonly reported, in 145 RCTs (62%) whereas visual field outcomes were utilized in 38 RCTs (16%).

Conclusions: There is a large variability in clinical outcomes used for glaucoma RCTs and in the way each outcome is reported. This lack of standardisation may impair the ability to evaluate the evidence of glaucoma interventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Comparing the relative effectiveness of interventions across glaucoma trials can be problematic due to differences in definitions of outcomes. We sought to identify a key set of clinical outcomes and reach consensus on how best to measure them from the perspective of glaucoma experts.

METHODS: A 2-round electronic Delphi survey was conducted. Round 1 involved 25 items identified from a systematic review. Round 2 was developed based on information gathered in round 1. A 10-point Likert scale was used to quantify importance and consensus of outcomes (7 outcomes) and ways of measuring them (44 measures). Experts were identified through 2 glaucoma societies membership-the UK and Eire Glaucoma Society and the European Glaucoma Society. A Nominal Group Technique (NGT) followed the Delphi process. Results were analyzed using descriptive statistics.

RESULTS: A total of 65 participants completed round 1 out of 320; of whom 56 completed round 2 (86%). Agreement on the importance of outcomes was reached on 48/51 items (94%). Intraocular pressure (IOP), visual field (VF), safety, and anatomic outcomes were classified as highly important. Regarding methods of measurement of IOP, "mean follow-up IOP" using Goldmann applanation tonometry achieved the highest importance, whereas for evaluating VFs "global index mean deviation/defect (MD)" and "rate of VF progression" were the most important. Retinal nerve fiber layer (RNFL) thickness measured by optical coherence tomography (OCT) was identified as highly important. The NGT results reached consensus on "change of IOP (mean of 3 consecutive measurements taken at fixed time of day) from baseline," change of VF-MD values (3 reliable VFs at baseline and follow-up visit) from baseline, and change of RNFL thickness (2 good quality OCT images) from baseline.

CONCLUSIONS: Consensus was reached among glaucoma experts on how best to measure IOP, VF, and anatomic outcomes in glaucoma randomized controlled trials.