25 resultados para Scanning reference electrode technique

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silver thin films were modified using a novel plasma modification process for the development of thin-film silver-silver chloride reference electrodes. The surface, physical, and electrochemical properties of these electrodes were investigated by atomic force microscopy, thickness and resistivity measurement techniques, as well as impedance spectroscopy and potentiometry. After plasma treatment, thin-film growth was observed and the electrodes, in general, exhibited low interface impedance and a roughened surface. Evidence of a complex surface reorganization was found. Correlating plasma conditions with film properties suggested that increasing pressure and exposure duration increased species availability, therefore governing the reaction rates, while input power appeared to influence the type of surface chemical reactions. Results also indicated that Ar/Cl-2 mixtures should be employed rather than pure chlorine plasmas. (C) 2002 The Electrochemical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A bluish-black shining free standing polypyrrole film (PPy) of electronic conductivity 130 S cm-1 has been prepared by electrochemical oxidative polymerization of pyrrole on Pt/transparent glass conducting electrode resistance 15 O cm-1, using a room temperature melt as an electrolyte, composed of 1:3 stoichiometric ratio of cetyl pyridinium chloride and anhydrous aluminum chloride at 0.58 V versus Al wire as a reference electrode. The film possessed a charge transfer resistance of 132 O, and showed two absorption peaks at 457 and 1264 nm in the UV-vis–NIR diffused reflectance spectra. The morphology of the film was hexagonal. The potential step technique suggested a layered structure. This thin film can easily be peeled off from the electrode surface after three cycles and can be used for various applications like dissipation of electrostatic charge, battery electrode materials, solid electrolytic capacitor, electrochromic windows and displays, microactuators etc. It was also characterized by IR, thermal and SEM studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The voltammetry and kinetics of the Ag vertical bar Ag+ system (commonly used as a reference electrode material in both protic/aprotic and RTIL solvents) was studied in the room-temperature ionic liquid N-butyl-N-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide, [C(4)mpyrr][NTf2] on a 10 mu m diameter Pt electrode. For the three silver salts investigated (AgOTf, AgNTf2, and AgNO3, where OTf- = trifluoromethanesulfonate, NTf2- = bis(trifluoromethylsulfonyl)imide, and NO3- = nitrate), the voltammetry gave rise to a redox couple characteristic of a

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a practical scheme for performing ab initio supercell calculations of charged slabs at constant electron chemical potential mu, rather than at constant number of electrons N-e. To this end, we define the chemical potential relative to a plane (or "reference electrode") at a finite distance from the slab (the distance should reflect the particular geometry of the situation being modeled). To avoid a net charge in the supercell, and thus make possible a standard supercell calculation, we restore the electroneutrality of the periodically repeated unit by means of a compensating charge, whose contribution to the total energy and potential is subtracted afterwards. The "constant mu" mode enables one to perform supercell calculation on slabs, where the slab is kept at a fixed potential relative to the reference electrode. We expect this to be useful in modeling many experimental situations, especially in electro-chemistry. (C) 2001 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Freestanding polyparaphenylene films were obtained on polymerization of benzene at potential of 1.2 V versus Al wire on substrates like platinum/transparent conducting glass as an anode. The electrolyte used was chloroaluminate room-temperature melt, which was prepared by intimate mixing of a 1:2 ratio of cetyl pyridinium chloride and anhydrous aluminum chloride to yield a viscous liquid. This liquid was miscible in all proportions with benzene and other aromatic hydrocarbons in all proportions at room temperature. The polyparaphenylene films deposited on platinum anode exhibited a prominent cyclic voltammetric peak at 0.7 V versus Al wire as reference electrode in chloroaluminate medium. The impedance spectra gave low charge transfer resistance. The diffused reflectance electronic spectra of the film gave the peaks at 386 nm and 886 nm. The PPP films showed electronic conductivity around 3–4 × 104 S/cm by four probe method under nitrogen atmosphere. The polymer was also characterized by IR spectra, thermal studies, and SEM studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mechanism of sulfur dioxide reduction at a platinum microelectrode was investigated by cyclic voltammetry in several room-temperature ionic liquids (RTILs)-[C(2)mim][NTf2], [C(4)mim][BF4], [C(4)mim][NO3], [C(4)mim][PF6], and [C(6)mim][Cl] where [C(2)mim] is 1-ethyl-3-methylimidazolium, [C(4)mim] is 1-butyl-3-methylimidazolium, [C(6)mim] is 1-hexyl-3-methylimidazolium, and [NTf2] is bis(trifluoromethylsufonyl)imide-with special attention paid to [C(4)mim][NO3] because of the well-defined voltammetry, high solubility, and relatively low diffusion coefficient of SO2 obtained in that ionic liquid. A cathodic peak is observed in all RTILs between -2.0 and -1.0 V versus a silver quasi-reference electrode. In [C(4)mim][NO3], the peak appears at -1.0 V, and potential step chronoamperometry was used to determine that SO2 has a very high solubility of 3100 (+/-450) mM and a diffusion coefficient of 5.0 (+/-0.8) x 10(-10) m(2) s(-1) in that ionic liquid. On the reverse wave, up to four anodic peaks are observed at ca. -0.4, -0.3, -0.2, and 0.2 V in [C(4)mim][NO3]. The cathodic wave is assigned to the reduction of SO2 to its radical anion, SO2-center dot. The peaks at -0.4 and -0.2 V are assigned to the oxidation of unsolvated and solvated SO2-center dot, respectively. The peak appearing at 0.2 V is assigned to the oxidation of either S2O42- or S2O4-center dot. The activation energy for the reduction of SO2 in [C(4)mim][NO3] was measured to be 10 (+/-2) kJ mol(-1) using chronoamperometric data at different temperatures. The stabilizing interaction of the solvent with the reduced species SO2-center dot leads to a different mechanism than that observed in conventional aprotic solvents. The high sensitivity of the system to SO2 also suggests that [C(4)mim][NO3] may be a viable solvent in gas sensing applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental standing wave oscillations of the interfacial potential across an electrode have been observed in the electrocatalytic oxidation of formic acid on a Pt ring working electrode. The instantaneous potential distribution was monitored by means of equispaced potential microprobes along the electrode. The oscillatory standing waves spontaneously arose from a homogeneous stationary state prior to a Hopf bifurcation if the reference electrode was placed close to the working electrode. Reduced electrolyte concentrations resulted in aperiodic potential patterns, while the presence of a sufficiently large ohmic resistance completely suppressed spatial inhomogeneities. The experimental findings confirm numerical predictions of a reaction-migration formalism: under the chosen geometry, a long-range negative potential coupling between distant points across the ring electrode can lead to oscillatory potential domains of distinct phase. It is further shown that the occurrence of oscillatory standing waves can be rationalized as the electrochemical equivalent of Turing's second bifurcation (wave bifurcation). In the presence of an external resistance, the coupling becomes positive throughout and leads to spatial synchronization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Contaminating tumour cells in apheresis products have proved to influence the outcome of patients with multiple myeloma (MM) undergoing autologous stem cell transplantation (APBSCT). The gene scanning of clonally rearranged VDJ segments of the heavy chain immunoglobulin gene (VDJH) is a reproducible and easy to perform technique that can be optimised for clinical laboratories. We used it to analyse the aphereses of 27 MM patients undergoing APBSCT with clonally detectable VDJH segments, and 14 of them yielded monoclonal peaks in at least one apheresis product. The presence of positive results was not related to any pre-transplant characteristics, except the age at diagnosis (lower in patients with negative products, P = 0.04). Moreover, a better pre-transplant response trended to associate with a negative result (P = 0.069). Patients with clonally free products were more likely to obtain a better response to transplant (complete remission, 54% vs 28%; >90% reduction in the M-component, 93% vs 43% P = 0.028). In addition, patients transplanted with polyclonal products had longer progression-free survival, (39 vs 19 months, P = 0.037) and overall survival (81% vs 28% at 5 years, P = 0.045) than those transplanted with monoclonal apheresis. In summary, the gene scanning of apheresis products is a useful and clinically relevant technique in MM transplanted patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present work we consider two aspects of the deposition of metal clusters on an electrode surface. The formation of such clusters with the tip of a scanning tunneling microscope is simulated by atom dynamics. Subsequently the stability of these clusters is investigated by Monte Carlo simulations in a grand-canonical ensemble. In particular, the following systems were considered explicitly: Pd clusters on Au(111), Cu on Au(111), Ag on Au(111), Pb on Au(111) and Cu on Ag(111). The analysis of the results obtained for the different systems leads to the conclusion that optimal systems for nanostructuring are those where the metals participating have similar cohesive energies and negative heats of alloy formation. In this respect, the system Cu-Pd(111) is predicted as a good candidate for the formation of stable clusters. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Palladium clusters have been deposited on the surface of a Au(111) electrode with the tip of a scanning tunnelling microscope. The distance over which the tip was moved towards the surface has a decisive influence on the properties of the clusters: the larger this distance, the larger the generated clusters, and the more stable they are. These findings are supported by computer simulations, which further suggest that the larger clusters contain a sizable amount of gold, which enhances their stability. Dissolution of the clusters occurs from the edges rather than layer by layer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MTDSC is a software modification of the traditional DSC thermal analysis technique that allows more accurate determination of the glass transition as well as measurement of the endothermic relaxation that often accompanies the transition. The glass transition is an essential parameterboth of the original frozen solution and of the end product. Measurement of endothermic relaxation allows the determination of molecularrelaxation times in the freeze-dried product that may be useful in predicting the effect of formulation variables and storage conditions on physical stability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The introduction of functional data into the radiotherapy treatment planning process is currently the focus of significant commercial, technical, scientific and clinical development. The potential of such data from positron emission tomography (PET) was recognized at an early stage and was integrated into the radiotherapy treatment planning process through the use of image fusion software. The combination of PET and CT in a single system (PET/CT) to form an inherently fused anatomical and functional dataset has provided an imaging modality which could be used as the prime tool in the delineation of tumour volumes and the preparation of patient treatment plans, especially when integrated with virtual simulation. PET imaging typically using F-Fluorodeoxyglucose (F-FDG) can provide data on metabolically active tumour volumes. These functional data have the potential to modify treatment volumes and to guide treatment delivery to cells with particular metabolic characteristics. This paper reviews the current status of the integration of PET and PET/CT data into the radiotherapy treatment process. Consideration is given to the requirements of PET/CT data acquisition with reference to patient positioning aids and the limitations imposed by the PET/CT system. It also reviews the approaches being taken to the definition of functional/ tumour volumes and the mechanisms available to measure and include physiological motion into the imaging process. The use of PET data must be based upon a clear understanding of the interpretation and limitations of the functional signal. Protocols for the implementation of this development remain to be defined, and outcomes data based upon clinical trials are still awaited. © 2006 The British Institute of Radiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of the surface zone of concrete is acknowledged as a major factor governing the rate of deterioration of reinforced concrete structures as it provides the only barrier to the ingress of water containing dissolved ionic species such as chlorides which, ultimately, initiate corrosion of the reinforcement. In-situ monitoring of cover-zone concrete is therefore critical in attempting to make realistic predictions as to the in-service performance of the structure. To this end, this paper presents developments in a remote interrogation system to allow continuous, real-time monitoring of the cover-zone concrete from an office setting. Use is made of a multi-electrode array embedded within cover-zone concrete to acquire discretized electrical resistivity and temperature measurements, with both parameters monitored spatially and temporally. On-site instrumentation, which allows remote interrogation of concrete samples placed at a marine exposure site, is detailed, together with data handling and processing procedures. Site-measurements highlight the influence of temperature on electrical resistivity and an Arrhenius-based temperature correction protocol is developed using on-site measurements to standardize resistivity data to a reference temperature; this is an advancement over the use of laboratory-based procedures. The testing methodology and interrogation system represents a robust, low-cost and high-value technique which could be deployed for intelligent monitoring of reinforced concrete structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The potentiometric and AC impedance characteristics of all solid-state sodium-selective electrodes based on planar screen-printed Ag/AgCl electrodes are described. Two solid-state designs have been investigated. The first was based on the deposition of a sodium-selective PVC membrane directly on top of a screen-printed Ag/AgCl electrode, The second design included a NaCl doped hydrogel layer, between the PVC and Ag\AgCl layers. The hydrogel provides a mechanism to relieve any blockage to charge transfer occurring when PVC membranes are used directly on top of Ag/AgCl and also improves adhesion between the two layers. Results suggest the electrodes display Fast ion exchange kinetics, low noise and drift. The performance compares favorably to that of a conventional ion-selective electrode with internal filling solution.