16 resultados para Restraint System Tests.

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Run Off Road (ROR) crashes are road accidents that often result in severe injuries or fatalities. To reduce the severity of ROR crashes, “forgiving roadsides” need to be designed and this includes identifying situations where there is a need for a Vehicle Restraint System (VRS) and what appropriate VRS should be selected for a specific location and traffic condition. Whilst there are standards covering testing, evaluation and classification of VRS within Europe (EN1317 parts 1 to 8), their selection, location and installation requirements are typically based upon national guidelines and standards, often produced by National Road Authorities (NRA) and/or overseeing organisations. Due to local conditions, these national guidelines vary across Europe.
The European SAVeRS project funded by CEDR has developed a practical and readily understandable VRS guidance document and a user-friendly software tool which allow designers and road administrations to select the most appropriate solution in different road and traffic conditions.
This paper describes the main outcomes of the project, the process to select the most appropriate roadside barrier, and the user friendly SAVeRS tool.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Sympathetic and parasympathetic divisions of the autonomic nervous system constantly control the heart (sympathetic and parasympathetic divisions) and blood vessels (predominantly the sympathetic division) to maintain appropriate blood pressure and organ blood flow over sometimes widely varying conditions. This can be adversely affected by pathological conditions that can damage one or both branches of autonomic control. The set of teaching laboratory activities outlined here uses various interventions, namely, 1) the heart rate response to deep breathing, 2) the heart rate response to a Valsalva maneuver, 3) the heart rate response to standing, and 4) the blood pressure response to standing, that cause fairly predictable disturbances in cardiovascular parameters in normal circumstances, which serve to demonstrate the dynamic control of the cardiovascular system by autonomic nerves. These tests are also used clinically to help investigate potential damage to this control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It has recently been demonstrated that patients with Angelman's syndrome who exhibited a deletion on cytogenetic tests show more severe clinical pictures with drug-resistant epilepsy than patients with Angelman's syndrome not carrying the deletion. To verify if this difference in clinical severity can be attributed to genes for the three gamma-aminobutyric acid (GABA)A receptor subunits (GABRB3, GABRA5, GABRG3) located in the deleted region, a possible modification of peripheral markers of the GABAergic system was investigated in 12 subjects with Angelman's syndrome and 20 age-matched subjects (8 with idiopathic epilepsy and 12 not affected by neurologic diseases). The results confirmed a more severe clinical picture, and epilepsy syndrome in particular, in Angelman's syndrome patients with deletions versus patients without deletions. In contrast, biochemical study (based on dosage of plasma levels of GABA and diazepam binding inhibitor, an endogenous ligand of GABAA and peripheral benzodiazepine receptors, showed contradictory results: patients with Angelman's syndrome showed significantly higher levels of GABA and diazepam binding inhibitor than patients without neurologic impairment but significantly lower levels than epileptic controls.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The LifeShirt is a novel ambulatory monitoring system that records cardio respiratory measurements outside the laboratory. Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt were assessed and two methods of calibrating the LifeShirt were compared. Participants performed an incremental treadmill test and a constant work rate test (65% peak oxygen uptake) on four occasions (>48 In apart) and wore the LifeShirt, COSMED system and Polar Sport Tester simultaneously. The LifeShirt was calibrated using two methods: comparison to a spirometer; and 800 ml fixed-volume bag. Ventilation, respiratory rate, expiratory time and heart rate recorded by the LifeShirt were compared to measurements recorded by laboratory equipment. Sixteen adults participated (6M: 10F); mean (SD) age 23.1 (2.9) years. Agreement between the LifeShirt and laboratory equipment was acceptable. Agreement for ventilation was improved by calibrating the LifeShirt using a spirometer. Reliability was similar for the LifeShirt and the laboratory equipment. This study suggests that the LifeShirt provides a valid and reliable method of ambulatory monitoring. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Unsaturated soils constitute a large proportion of the foundation materials supporting infrastructure throughout the world and they are subject to various loading conditions. This paper describes the development of a simple system for testing unsaturated soils under repeated loading. The equipment was comprised of a modified triaxial cell with hydraulic loading system, hall-effect transducers for on-sample strain measurements, and thermocouple psychrometer for suction measurements. A number of undrained monotonic and repeated loading triaxial tests were performed on compacted samples of kaolin clay in order to attest the newly developed system. The results yielded some useful information on the resilient modulus and permanent deformation of a soil when subjected to repeated loading. There is some difference between the failure deviator stress of samples subjected to repeated and monotonic loading, though repeated loading continued to result in a significant permanent deformation. This paper is aimed at demonstrating the key features of the equipment using preliminary data generated as part of the on-going research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Screening for residues of anabolic steroids frequently requires extraction from tissues and fluids before analysis. Chemical procedures for these extractions can be complicated, expensive to perform and not ideal for the simultaneous extraction of analytes with different solubilities. Extraction by multi-immunoaffinity chromatography (MIAC) may be used as an alternative. Samples are passed through a column containing a range of antibodies immobilized on an inert support. The desired analytes are bound to their respective antibodies, washed and then eluted by a suitable solvent. The purified extracts can then be incorporated into the analytical tests, The analytes that can be extracted presently are alpha-nortestosterone, zeranol, trenbolone, diethylstilboestrol, boldenone and dexamethasone. Manually, the MIAC procedure is limited to about six columns per operator but bq automating the process using a robotic sample processor (RSP), 48 columns can be run simultaneously during the day or night. The RSP has also been adapted to transfer extracts and reagents on to ELISA plates. The automated system has proved to be a robust and reliable means of screening large numbers of samples for anabolic agents with minimal manual input

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The many-electron-correlated scattering (MECS) approach to quantum electronic transport was investigated in the linear-response regime [I. Bâldea and H. Köppel, Phys. Rev. B 78, 115315 (2008). The authors suggest, based on numerical calculations, that the manner in which the method imposes boundary conditions is unable to reproduce the well-known phenomena of conductance quantization. We introduce an analytical model and demonstrate that conductance quantization is correctly obtained using open system boundary conditions within the MECS approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method was devised to grow haemopoietic cells in long-term bone marrow culture (LTBMC) which requires only 1 x 10(6) cells/culture. Such miniature cultures were used to study growth patterns of marrow from patients with myelodysplastic syndromes (MDS). Consistent differences in LTBMC cellularity and cellular composition were noted between MDS and normal marrow. These differences were accentuated by rGM-CSF. The criteria which distinguished between and MDS marrows were: cell count at weeks 1 and 4, % neutrophils and % blasts. In 10 patients with unexplained macrocytosis or pancytopenia miniature LTBMC results clearly segregated into either 'normal' or 'MDS' growth patterns. Miniature LTBMC with rGM-CSF may therefore be a useful diagnostic test for early MDS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to explore nurses' perceptions of and level of satisfaction with the medication administration system in long-term care (LTC). The cross-sectional survey design included both quantitative and open-ended questions. Data were collected from licensed registered nurses (RNs) and registered practical nurses (RPNs) at 9 LTC residences in southwestern Ontario, Canada. Using independent sample f tests, the researchers found that RNs were significantly less satisfied than RPNs with their medication administration system, particularly with respect to safety issues. RNs identified a number of related barriers, including time constraints, poor packaging, insufficient drug information, prescription changes, lack of staff competency, and unwieldy medication carts. Implications for practice and policy are discussed, including recommendations for improving medication administration practices and for addressing the workload demands of LTC nurses. © McGill University School of Nursing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the design, commissioning, and evaluation of a ?ber-optic strain sensor system for the structural health monitoring of a prestressed concrete posttensioned box girder railway bridge in Mumbai, India, which shows a number of well-documented structural problems. Preliminary laboratory trials to design the most appropriate sensor system that could be readily transported and used on site are described, followed by a description of load tests on the actual bridge undertaken in collaboration with Indian Railways and using locomotives of known weight. Results from the load tests using the optical system are compared with similar results obtained using electrical resistance strain gages. Conclusions are summarized concerning the integrity of the structure and for the future use of the sensor system for monitoring bridges of this type. Crack width measurements obtained during the load tests are also described.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Earth pressure balanced (EPB) full face tunneling machines have experienced a remarkable increase in the number of applications throughout the world due to both mechanical developments and a more effective use of additives to condition the ground. Conditioning modifies the mechanical and hydraulic properties of a soil by making it suitable for the pressure control in the bulk chamber and extraction with the screw conveyor. The extraction system plays a fundamental role during the EPB operations particularly for a correct application of the face pressure. Despite the extensive use of the EPB technique, little knowledge exists concerning the understanding of the behavior of conditioned soil, particularly for noncohesive ground (sand and gravel). This paper presents and describes a prototype laboratory device, which simulates the extraction of the ground from a pressurized tank with a screw conveyor. The results of a preliminary test program carried out on a medium sized sand show that the prototype device is efficient in verifying the effects of foam for an optimal use in EPB conditioning. © 2007 ASCE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The screw conveyor system plays a fundamental role during the EPB tunnelling operations for the tunnel face pressure control. On the other hand, the use of additives such chemical foams is even more applied in order to extend the EPB technology to the cohesionless soils. Despite the extensive use of the EPB technique in urban environment, little knowledge exists in the understanding of the behavior of such conditioned soil during the excavation operations. At the Turin University of Technology the Tunnelling and Underground Space Centre, in the mainframe of a wider research on soil conditioning, has developed an experimental apparatus that simulates the extraction phase with screw conveyor from a pressurized tank. In this paper the apparatus is presented and the results of a first series of tests carried out on sand are discussed. © 2007 Taylor & Francis Group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this research is to use finite element analysis (FEA) to quantify the effect of the sample shape and the imperfections induced during the manufacturing process of samples on the bond strength and modes of failure of dental adhesive systems through microtensile test. Using the FEA prediction for individual parameters effect, estimation of expected variation and spread of the microtensile bond strength results for different sample geometries is made. Methods: The estimated stress distributions for three different sample shapes, hourglass, stick and dumbbell predicted by FEA are used to predict the strength for different fracture modes. Parameters such as the adhesive thickness, uneven interface of the adhesive and composite and dentin, misalignment of axis of loading, the existence of flaws such as induced cracks during shaping the samples or bubbles created during application of the adhesive are considered. Microtensile experiments are performed simultaneously to measure bond strength and modes of failure. These are compared with the FEA results. Results: The relative bonding strength and its standard deviation for the specimens with different geometries measured through the microtensile tests confirm the findings of the FEA. The hourglass shape samples show lower tensile bond strength and standard deviation compared to the stick and dumbbell shape samples. ANOVA analysis confirms no significant difference between dumbbell and stick geometry results, and major differences of these two geometries compared to hourglass shape measured values. Induced flaws in the adhesive and misalignment of the angle of application of load have significant effect on the microtensile bond strength. Using adhesive with higher modulus the differences between the bond strength of the three sample geometries increase. Significance: The result of the research clarifies the importance of the sample geometry chosen in measuring the bond strength. It quantifies the effect of the imperfections on the bond strength for each of the sample geometries through a systematic and all embracing study. The results explain the reasons of the large spread of the microtensile test results reported by various researchers working in different labs and the need for standardization of the test method and sample shape used in evaluation of the dentin-adhesive bonding system. © 2007 Academy of Dental Materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Few studies have examined the impact that the adoption of the secret ballot had on party system fragmentation outside the United States. This article tests arguments maintaining that the adoption of the secret ballot had a negative, positive or nil effect on party system fragmentation. Using time-series cross-sectional data from
several countries adopting the secret ballot around the turn of the twentieth century, the results demonstrate that the adoption of the secret ballot did not hinder – though did not favour, either – the development of multiparty systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bonded-in rod connections in timber possess many desirable attributes in terms of efficiency, manufacture, performance, aesthetics and cost. In recent years research has been conducted on such connections using fibre reinforced polymers (FRPs) as an alternative to steel. This research programme investigates the pull-out capacity of Basalt FRP rods bonded-in in low grade Irish Sitka Spruce. Embedded length is thought to be the most influential variable contributing to pull- out capacity of bonded-in rods after rod diameter. Previous work has established an optimum embedded length of 15 times the hole diameter. However, this work only considered the effects of axial stress on the bond using a pull-compression testing system which may have given an artificially high pull out capacity as bending effects were neglected. A hinge system was utilised that allows the effects of bending force to be taken in to consideration along with axial forces in a pull-out test. This paper describes an experimental programme where such pull-bending tests were carried out on samples constructed of 12mm diameter BFRP bars with a 2mm glueline thickness and embedded lengths between 80mm and 280mm bonded-in to low-grade timber with an epoxy resin. Nine repetitions of each were tested. A clear increase in pull-out strength was found with increasing embedded length.