180 resultados para Respiratory Gating

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Intrafraction tumour motion is an issue that is of increased interest in the era of image-guided radiotherapy. It is particularly relevant for non-small cell lung cancer, for which a number of recent developments are in use to aid with motion management in the delivery of radical radiotherapy. The ability to deliver hypofractionated ablative doses, such as in stereotactic radiotherapy, has been aided by improvements in the ability to analyse tumour motion and amend treatment delivery. In addition, accounting for tumour motion can enable dose escalation to occur by reducing the normal tissue being irradiated by virtue of a reduction in target volumes. Motion management for lung tumours incorporates five key components: imaging, breath-hold techniques, abdominal compression, respiratory tracking and respiratory gating. These will be described, together with the relevant benefits and associated complexities. Many studies have described improved dosimetric coverage and reduced normal tissue complication probability rates when using motion management techniques. Despite the widespread uptake of many of these techniques, there is a paucity of literature reporting improved outcome in overall survival and local control for patients whenever motion management techniques are used. This overview will review the extent of lung tumour motion, ways in which motion is detected and summarise the key methods used in motion management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to track and verify the delivery of respiratory-gated irradiations, performed with three versions of TrueBeam linac, using a novel phantom arrangement that combined the OCTAVIUS® SRS 1000 array with a moving platform. The platform was programmed to generate sinusoidal motion of the array. This motion was tracked using the real-time position management (RPM) system and four amplitude gating options were employed to interrupt MV beam delivery when the platform was not located within set limits. Time-resolved spatial information extracted from analysis of x-ray fluences measured by the array was compared to the programmed motion of the platform and to the trace recorded by the RPM system during the delivery of the x-ray field. Temporal data recorded by the phantom and the RPM system were validated against trajectory log files, recorded by the linac during the irradiation, as well as oscilloscope waveforms recorded from the linac target signal. Gamma analysis was employed to compare time-integrated 2D x-ray dose fluences with theoretical fluences derived from the probability density function for each of the gating settings applied, where gamma criteria of 2%/2 mm, 1%/1 mm and 0.5%/0.5 mm were used to evaluate the limitations of the RPM system. Excellent agreement was observed in the analysis of spatial information extracted from the SRS 1000 array measurements. Comparisons of the average platform position with the expected position indicated absolute deviations of  <0.5 mm for all four gating settings. Differences were observed when comparing time-resolved beam-on data stored in the RPM files and trajectory logs to the true target signal waveforms. Trajectory log files underestimated the cycle time between consecutive beam-on windows by 10.0  ±  0.8 ms. All measured fluences achieved 100% pass-rates using gamma criteria of 2%/2 mm and 50% of the fluences achieved pass-rates  >90% when criteria of 0.5%/0.5 mm were used. Results using this novel phantom arrangement indicate that the RPM system is capable of accurately gating x-ray exposure during the delivery of a fixed-field treatment beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of quality of life (QOL) is necessary to monitor the course of disease and to assess the effect of new and existing interventions in clinical practice. This will only be achieved if QOL can be measured accurately and routinely. The aim of this study was to demonstrate the methodology involved in the adaptation and shortening of the Chronic Respiratory Disease Questionnaire (CRDQ) in a population of adults with cystic fibrosis (CF). A single interviewer administered the CRDQ to a sample of 45 adult patients (32 males) with CF prior to assessment of spirometric measures of lung function. Those patients whose lung function was stable at the time of study, and who could attend for a retest within 14 days, were asked to complete the questionnaire at a subsequent visit (n=10). The average interval between visits was 7 days (range 5-14 days). Correlations between spirometry and CRDQ dimensions ranged from -0.003 to 0.426. The fatigue, emotion and mastery dimensions showed high internal consistency, and adequate construct validity. In the small number of patients suitable for retest, the results indicated that the dimensions exhibited adequate test retest reliability. In contrast low internal consistency was demonstrated for the dyspnoea dimension. The fatigue, emotion and mastery dimensions could be reduced, in terms of their number of items without a substantial loss in explanatory power. This study suggests that QOL measurement can be made convenient, and so more easily accessible for routine clinical assessment.