65 resultados para Reliability of Path

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Arc-Length Method is a solution procedure that enables a generic non-linear problem to pass limit points. Some examples are provided of mode-jumping problems solutions using a commercial nite element package, and other investigations are carried out on a simple structure of which the numerical solution can be compared with an analytical one. It is shown that Arc-Length Method is not reliable when bifurcations are present in the primary equilibrium path; also the presence of very sharp snap-backs or special boundary conditions may cause convergence diÆculty at limit points. An improvement to the predictor used in the incremental procedure is suggested, together with a reliable criteria for selecting either solution of the quadratic arc-length constraint. The gap that is sometimes observed between the experimantal load level of mode-jumping and its arc-length prediction is explained through an example.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this experiment was to assess the test-retest reliability of input-output parameters of the cortico-spinal pathway derived from transcranial magnetic (TMS) and electrical (TES) stimulation at rest and during muscle contraction. Motor evoked potentials (MEPs) were recorded from the first dorsal interosseous muscle of eight individuals on three separate days. The intensity of TMS at rest was varied from 5% below threshold to the maximal output of the stimulator. During trials in which the muscle was active, TMS and TES intensities were selected that elicited MEPs of between 150 and 300 X at rest. MEPs were evoked while the participants exerted torques up to 50% of their maximum capacity. The relationship between MEP size and stimulus intensity at rest was sigmoidal (R-2 = 0.97). Intra-class correlation coefficients (ICC) ranged between 0.47 and 0.81 for the parameters of the sigmoid function. For the active trials, the slope and intercept of regression equations of MEP size on level of background contraction were obtained more reliably for TES (ICC = 0.63 and 0.78, respectively) than for TMS (ICC = 0.50 and 0.53, respectively), These results suggest that input-output parameters of the cortico-spinal pathway may be reliably obtained via transcranial stimulation during longitudinal investigations of cortico-spinal plasticity. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electronprobe microanalysis is now widely adopted in tephra studies as a technique for determining the major element geochemistry of individual glass shards. Accurate geochemical characterization is crucial for enabling robust tephra-based correlations; such information may also be used to link the tephra to a specific source and often to a particular eruption. In this article, we present major element analyses for rhyolitic natural glass standards analysed on three different microprobes and the new JEOL FEGSEM 6500F microprobe at Queen’s University Belfast. Despite the scatter in some elements, good comparability is demonstrated among data yielded from this new system, the previous Belfast JEOL-733 Superprobe, the JEOL-8200 Superprobe (Copenhagen) and the existing long-established microprobe facility in Edinburgh. Importantly, our results show that major elements analysed using different microprobes and variable operating conditions allow two high-silica glasses to be discriminated accurately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The LifeShirt is a novel ambulatory monitoring system that records cardio respiratory measurements outside the laboratory. Validity and reliability of cardiorespiratory measurements recorded by the LifeShirt were assessed and two methods of calibrating the LifeShirt were compared. Participants performed an incremental treadmill test and a constant work rate test (65% peak oxygen uptake) on four occasions (>48 In apart) and wore the LifeShirt, COSMED system and Polar Sport Tester simultaneously. The LifeShirt was calibrated using two methods: comparison to a spirometer; and 800 ml fixed-volume bag. Ventilation, respiratory rate, expiratory time and heart rate recorded by the LifeShirt were compared to measurements recorded by laboratory equipment. Sixteen adults participated (6M: 10F); mean (SD) age 23.1 (2.9) years. Agreement between the LifeShirt and laboratory equipment was acceptable. Agreement for ventilation was improved by calibrating the LifeShirt using a spirometer. Reliability was similar for the LifeShirt and the laboratory equipment. This study suggests that the LifeShirt provides a valid and reliable method of ambulatory monitoring. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The blood pressure waveform is modified on distal propagation by phenomena such as dispersion, reflection and the state of the arterial compliance. The consequent effects are amplification and narrowing of the wave, with an increased systolic, reduced diastolic and essentially unaltered mean blood pressure. The Finapres measures the peripheral pressure using the volume clamp principle; it has not been validated under altered physiological conditions and during pharmacodynamic interventions. We studied simultaneous Finapres and brachial blood pressures (using a conventional oscillometric sphygmomanometer—Vitalmap) in ten normal volunteers at rest, and during dynamic exercise and a cold pressor test. The effects of pharmacodynamic intervention were examined following beta-adrenoceptor blockade with propranolol (160 mg) or beta-adrenoceptor modulation with the beta-adrenoceptor partial agonist celiprolol (400 mg). The Finapres systolic pressure was significantly higher than the brachial value during all three test states. The difference between the systolic pressures measured by the two devices was shown to increase significantly during the cold pressor test, but not during dynamic (supine bicycle) exercise. The Finapres diastolic pressure was significantly higher than the Vitalmap value during exercise and the cold pressor test. The differences between the two methods increased significantly over time. Beta-adrenergic blockade with propranolol or modulation with celiprolol had no significant interaction with the pressure differences between the Finapres and Vitalmap techniques. The results would support the view that the Finapres can provide blood pressure information which is robust under most circumstances. Although this pharmacodynamic intervention did not alter the relationship between the peripheral and central blood pressure, it is important to note that this dynamic relationship is sensitive to circulatory loading conditions and wave transmission characteristics; it is possible that the Finapres could be less reliable in clinical settings where potent vasoactive agents were being administered.