407 resultados para Refraction, Astronomical.

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the nonlinear propagation of electromagnetic waves in left-handed materials. For this purpose, we consider a set of coupled nonlinear Schrodinger (CNLS) equations, which govern the dynamics of coupled electric and magnetic field envelopes. The CNLS equations are used to obtain a nonlinear dispersion, which depicts the modulational stability profile of the coupled plane-wave solutions in left-handed materials. An exact (in)stability criterion for modulational interactions is derived, and analytical expressions for the instability growth rate are obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A quantitative study of refractive whole beam defocusing and small scale breakup induced by optical ionization of subpicosecond and picosecond, 0.25 and 1 mu m, laser pulses in gas-jet targets at densities above 1 x 10(19) cm(-3) has been carried out. A significant reduction of the incident laser intensity was observed due to refraction from ionization-induced density gradients. The level of refraction measured with optical probing correlated well with the fraction of energy transmitted through the plasma. The numerical and analytical models were found to agree well with experimental observations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a study on the gender balance, in speakers and attendees, at the recent major astronomical conference, the American Astronomical Society meeting 223, in Washington, DC. We conducted an informal survey, yielding over 300 responses by volunteers at the meeting. Each response included gender data about a single talk given at the meeting, recording the gender of the speaker and all question-askers. In total, 225 individual AAS talks were sampled. We analyze basic statistical properties of this sample. We find that the gender ratio of the speakers closely matched the gender ratio of the conference attendees. The audience asked an average of 2.8 questions per talk. Talks given by women had a slightly higher number of questions asked (3.2$\pm$0.2) than talks given by men (2.6$\pm$0.1). The most significant result from this study is that while the gender ratio of speakers very closely mirrors that of conference attendees, women are under-represented in the question-asker category. We interpret this to be an age-effect, as senior scientists may be more likely to ask questions, and are more commonly men. A strong dependence on the gender of session chairs is found, whereby women ask disproportionately fewer questions in sessions chaired by men. While our results point to laudable progress in gender-balanced speaker selection, we believe future surveys of this kind would help ensure that collaboration at such meetings is as inclusive as possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A significant portion of the UK’s transportation system relies on a network of geotechnical earthworks (cuttings and embankments) that were constructed more than 100 years ago, whose stability is affected by the change in precipitation patterns experienced over the past few decades. The vulnerability of these structures requires a reliable, cost- and time-effective monitoring of their geomechanical condition. We have assessed the potential application of P-wave refraction for tracking the seasonal variations of seismic properties within an aged clay-filled railway embankment, located in southwest England. Seismic data were acquired repeatedly along the crest of the earthwork at regular time intervals, for a total period of 16 months. P-wave first-break times were picked from all available recorded traces, to obtain a set of hodocrones referenced to the same spatial locations, for various dates along the surveyed period of time. Traveltimes extracted from each acquisition were then compared to track the pattern of their temporal variability. The relevance of such variations over time was compared with the data experimental uncertainty. The multiple set of hodocrones was subsequently inverted using a tomographic approach, to retrieve a time-lapse model of VPVP for the embankment structure. To directly compare the reconstructed VPVP sections, identical initial models and spatial regularization were used for the inversion of all available data sets. A consistent temporal trend for P-wave traveltimes, and consequently for the reconstructed VPVP models, was identified. This pattern could be related to the seasonal distribution of precipitation and soil-water content measured on site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. DESIGN: Cross-sectional study. PARTICIPANTS: Chinese school-children aged 12 to 17 years. METHODS: Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm of the minimum angle of resolution visual acuity, habitual correction, self-refraction without cycloplegia, autorefraction with and without cycloplegia, and subjective refraction with cycloplegia. MAIN OUTCOME MEASURES: Proportion of children achieving corrected visual acuity ≥ 6/7.5 with each modality; difference in spherical equivalent refractive error between each of the modalities and cycloplegic subjective refractive error. RESULTS: Among 556 eligible children of consenting parents, 554 (99.6%) completed self-refraction (mean age, 13.8 years; 59.7% girls; 54.0% currently wearing glasses). The proportion of children with visual acuity ≥ 6/7.5 in the better eye with habitual correction, self-refraction, noncycloplegic autorefraction, and cycloplegic subjective refraction were 34.8%, 92.4%, 99.5% and 99.8%, respectively (self-refraction versus cycloplegic subjective refraction, P<0.001). The mean difference between cycloplegic subjective refraction and noncycloplegic autorefraction (which was more myopic) was significant (-0.328 diopter [D]; Wilcoxon signed-rank test P<0.001), whereas cycloplegic subjective refraction and self-refraction did not differ significantly (-0.009 D; Wilcoxon signed-rank test P = 0.33). Spherical equivalent differed by ≥ 1.0 D in either direction from cycloplegic subjective refraction more frequently among right eyes for self-refraction (11.2%) than noncycloplegic autorefraction (6.0%; P = 0.002). Self-refraction power that differed by ≥ 1.0 D from cycloplegic subjective refractive error (11.2%) was significantly associated with presenting without spectacles (P = 0.011) and with greater absolute power of both spherical (P = 0.025) and cylindrical (P = 0.022) refractive error. CONCLUSIONS: Self-refraction seems to be less prone to accommodative inaccuracy than noncycloplegic autorefraction, another modality appropriate for use in areas where access to eye care providers is limited. Visual results seem to be comparable. Greater cylindrical power is associated with less accurate results; the adjustable glasses used in this study cannot correct astigmatism. Further studies of the practical applications of this modality are warranted. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

To estimate the heritability of peripheral refraction in Chinese children and adolescents.

METHODS:

The authors examined 72 monozygotic (MZ) twins and 48 dizygotic (DZ) twins aged 8 to 20 years from a population-based twin registry. Temporal and nasal peripheral refraction, each 40° from the visual axis, and axial refraction were measured using an autorefractor. Relative peripheral refractive error (RPRE) was defined as the peripheral refraction minus the axial refraction. Heritability was assessed by structural equation modeling after adjustment for age and sex.

RESULTS:

The mean and SD of temporal refraction (T(40)), nasal refraction (N(40)), RPRE-T(40), RPRE-N(40), and T(40)-N(40) asymmetry were -0.27 ± 2.0 D, 0.36 ± 2.19 D, 1.18 ± 1.39 D, 1.80 ± 1.69 D, and -0.62 ± 1.58 D, respectively. The intraclass correlations for T(40) refraction, N(40) refraction, RPRE-T(40), RPRE-N(40), and T(40)-N(40) asymmetry were 0.87, 0.83, 0.65, 0.74, and 0.58 for MZ pairs and 0.49, 0.42, 0.30, 0.41, and 0.32 for DZ pairs, respectively. A model with additive genetic and unique environmental effects was the most parsimonious, with heritability values estimated as 0.84, 0.76, 0.63, 0.70, and 0.55, respectively, for the peripheral refractive parameters.

CONCLUSIONS:

Additive genetic effects appear to explain most of the variance in peripheral refraction and relative peripheral refraction when adjusting for the effects of axial refraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To study, for the first time, the effect of wearing ready-made glasses and glasses with power determined by self-refraction on children's quality of life. METHODS: This is a randomized, double-masked non-inferiority trial. Children in grades 7 and 8 (age 12-15 years) in nine Chinese secondary schools, with presenting visual acuity (VA) ≤6/12 improved with refraction to ≥6/7.5 bilaterally, refractive error ≤-1.0 D and <2.0 D of anisometropia and astigmatism bilaterally, were randomized to receive ready-made spectacles (RM) or identical-appearing spectacles with power determined by: subjective cycloplegic retinoscopy by a university optometrist (U), a rural refractionist (R) or non-cycloplegic self-refraction (SR). Main study outcome was global score on the National Eye Institute Refractive Error Quality of Life-42 (NEI-RQL-42) after 2 months of wearing study glasses, comparing other groups with the U group, adjusting for baseline score. RESULTS: Only one child (0.18%) was excluded for anisometropia or astigmatism. A total of 426 eligible subjects (mean age 14.2 years, 84.5% without glasses at baseline) were allocated to U [103 (24.2%)], RM [113 (26.5%)], R [108 (25.4%)] and SR [102 (23.9%)] groups, respectively. Baseline and endline score data were available for 398 (93.4%) of subjects. In multiple regression models adjusting for baseline score, older age (p = 0.003) and baseline spectacle wear (p = 0.016), but not study group assignment, were significantly associated with lower final score. CONCLUSION: Quality of life wearing ready-mades or glasses based on self-refraction did not differ from that with cycloplegic refraction by an experienced optometrist in this non-inferiority trial.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple method to predict the densities of a range of ionic liquids from their surface tensions, and vice versa, using a surface-tension-weighted molar volume, the parachor, is reported. The parachors of ionic liquids containing 1-alkyl-3-methylimidazolium cations were determined experimentally, but were also calculated directly from their structural compositions using existing parachor contribution data for neutral compounds. The calculated and experimentally determined parachors were remarkably similar, and the latter data were subsequently employed to predict the densities and surface tensions of the investigated ionic liquids. Using a similar approach, the molar refractions of ionic liquids were determined experimentally, as well as calculated using existing molar refraction contribution data for uncharged compounds. The calculated molar refraction data were employed to predict the refractive indices of the ionic liquids from their surface tensions. The errors involved in the refractive index predictions were much higher than the analogous predictions employing the parachor, but nevertheless demonstrated the potential for developing parachor and molar refraction contribution data for ions as tools to predict ionic liquid physical properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Solar Eclipse Corona Imaging System (SECIS) observed a strong 6-s oscillation in an active region coronal loop, during the 1999 August 11 total solar eclipse. In the present paper we show that this oscillation is associated with a fast-mode magneto-acoustic wave that travels through the loop apex with a velocity of 2100 km s-1. We use near-simultaneous SOHO observations to calculate the parameters of the loop and its surroundings such as density, temperature and their spatial variation. We find that the temporal evolution of the intensity is in agreement with the model of an impulsively generated, fast-mode wave.