29 resultados para Ramp metering

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method for measuring the phase of oscillations from noisy time series is proposed. To obtain the phase, the signal is filtered in such a way that the filter output has minimal relative variation in the amplitude over all filters with complex-valued impulse response. The argument of the filter output yields the phase. Implementation of the algorithm and interpretation of the result are discussed. We argue that the phase obtained by the proposed method has a low susceptibility to measurement noise and a low rate of artificial phase slips. The method is applied for the detection and classification of mode locking in vortex flow meters. A measure for the strength of mode locking is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research aims to carry out a detailed analysis of the loads applied by the ambulance workers when loading/unloading ambulance stretchers. The forces required of the ambulance workers for each system are measured using a load cell in a force handle arrangement. The process of loading and unloading is video recorded for all the systems to register the posture of the ambulance workers in different stages of the process. The postures and forces exerted by the ambulance workers are analyzed using biomechanical assessment software to examine if the work loads at any stage of the process are harmful. Kinetic analysis of each stretcher loading system is performed. Comparison of the kinetic analysis and measurements shows very close agreement for most of the cases. The force analysis results are evaluated against derived failure criteria. The evaluation is extended to a biomechanical failure analysis of the ambulance worker's lower back using 3DSSPP software developed at the Centre for Ergonomics at the University of Michigan. The critical tasks of each ambulance worker during the loading and unloading operations for each system are identified. Design recommendations are made to reduce the forces exerted based on loading requirements from the kinetic analysis. © 2006 IPEM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the detailed validation of a computer model designed to simulate the transient light-off in a two-stroke oxidation catalyst. A plug flow reactor is employed to provide measurements of temperature and gas concentration at various radial and axial locations inside the catalyst. These measurements are recorded at discrete intervals during a transient light-off in which the inlet temperature is increased from ambient to 300oC at rates of up to 6oC/sec. The catalyst formulation used in the flow reactor, and its associated test procedures, are then simulated by the computer and a comparison made between experimental readings and model predictions. The design of the computer model to which this validation exercise relates is described in detail in a separate technical paper. The first section of the paper investigates the warm-up characteristics of the substrate and examines the validity of the heat transfer predictions between the wall and the gas in the absence of chemical reactions. The predictions from a typical single-component CO transient light-off test are discussed in the second section and are compared with experimental data. In particular the effect of the temperature ramp on the light-off curve and reaction zone development is examined. An analysis of the C3H6 conversion is given in the third section while the final section examines the accuracy of the light-off curves which are produced when both CO and C3H6 are present in the feed gas. The analysis shows that the heat and mass transfer calculations provided reliable predictions of the warm-up behaviour and post light-off gas concentration profiles. The self-inhibition and cross-inhibition terms in the global rate expressions were also found to be reasonably reliable although the surface reaction rates required calibration with experimental data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adrenomedullin (AM) and intermedin (IMD; adrenomedulln-2) are vasodilator peptides related to calcitonin gene-related peptide (CGRP). The actions of these peptides are mediated by the calcitonin receptor-like receptor (CLR) in association with one of three receptor activity-modifying proteins. CGRP is selective for CLR/receptor activity modifying protein (RAMP)1, AM for CLR/RAMP2 and -3, and IMD acts at both CGRP and AM receptors. In a model of pressure overload induced by inhibition of nitric-oxide synthase, up-regulation of AM was observed previously in cardiomyocytes demonstrating a hypertrophic phenotype. The current objective was to examine the effects of blood pressure reduction on cardiomyocyte expression of AM and IMD and their receptor components. Nomega-nitro-L-arginine methyl ester (L-NAME) (35 mg/kg/day) was administered to rats for 8 weeks, with or without concurrent administration of hydralazine (50 mg/kg/day) and hydrochlorothiazide (7.5 mg/kg/day). In left ventricular cardiomyocytes from L-NAME-treated rats, increases (-fold) in mRNA expression were 1.6 (preproAM), 8.4 (preproIMD), 3.4 (CLR), 4.1 (RAMP1), 2.8 (RAMP2), and 4.4 (RAMP3). Hydralazine/hydrochlorothiazide normalized systolic blood pressure (BP) and abolished mRNA up-regulation of hypertrophic markers sk-alpha-actin and BNP and of preproAM, CLR, RAMP2, and RAMP3 but did not normalize cardiomyocyte width nor preproIMD or RAMP1 mRNA expression. The robust increase in IMD expression indicates an important role for this peptide in the cardiac pathology of this model but, unlike AM, IMD is not associated with pressure overload upon the myocardium. The concordance of IMD and RAMP1 up-regulation indicates a CGRP-type receptor action; considering also a lack of response to BP reduction, IMD may, like CGRP, have an anti-ischemic function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes an example of spontaneous transitions between qualitatively different coordination patterns during a cyclic lifting and lowering task. Eleven participants performed 12 trials of repetitive lifting and lowering in a ramp protocol in which the height of the lower shelf was raised or lowered I cm per cycle between 10 and 50 cm. Two distinct patterns of coordination were evident: a squat technique in which moderate range of hip, knee and ankle movement was utilised and ankle plantar-flexion occurred simultaneously with knee and hip extension; and a stoop technique in which the range of knee movement was reduced and knee and hip extension was accompanied by simultaneous ankle dorsi-flexion. Abrupt transitions from stoop to squat techniques were observed during descending trials, and from squat to stoop during ascending trials. Indications of hysteresis was observed in that transitions were more frequently observed during descending trials, and the average shelf height at the transition was 5 cm higher during ascending trials. The transitions may be a consequence of a trade-off between the biomechanical advantages of each technique and the influence of the lift height on this trade-off. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the experiment was to compare the level of synchronization exhibited by pairs of motor units located within and between functionally distinct regions of the biceps brachii muscle. Pairs of single motor units were recorded from seven subjects using separate electrodes located in the lateral and medial aspects of the long head of biceps brachii. Participants were required to exert a combination of flexion and supination torques so that both motor units discharged at approximately 10 pps for a parts per thousand yen200 s and the level of motor unit synchronization could be quantified. When motor unit recordings were sufficiently stable at the completion of this synchrony task, a series of ramp contractions with multiple combinations of flexion and supination torques were performed to characterize the recruitment thresholds of the motor units. Common input strength (CIS) was significantly greater (P <0.01) for the within-region pairs of motor units (0.28 extra sync. imps/s, n = 26) than for the between-region pairs (0.13 extra sync. imps/s, n = 18), but did not differ significantly for the 12 within-region pairs from the lateral head and 14 from the medial head (0.27 vs. 0.29 extra sync. imps/s; P = 0.83). Recruitment thresholds were measured for 33 motor units, but there was only a weak association between CIS and the respective recruitment patterns for motor unit pairs (n = 9). The present investigation provides evidence of a differential distribution of synaptic input across the biceps brachii motor neuron pool, but this appears to have minimal association with the recruitment patterns for individual motor units.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intermedin (IMD) is a novel peptide related to calcitonin gene-related peptide (CGRP) and adrenomedullin (AM). Proteolytic processing of a larger precursor yields a series of biologically active C-terminal fragments, IMD1–53, IMD1–47 and IMD8–47. IMD shares a family of receptors with AM and CGRP composed of a calcitonin-receptor like receptor (CALCRL) associated with one of three receptor activity modifying proteins (RAMP). Compared to CGRP, IMD is less potent at CGRP1 receptors but more potent at AM1 receptors and AM2 receptors; compared to AM, IMD is more potent at CGRP1 receptors but less potent at AM1 and AM2 receptors. The cellular and tissue distribution of IMD overlaps in some aspects with that of CGRP and AM but is distinct from both. IMD is present in neonatal but absent or expressed sparsely, in adult heart and vasculature and present at low levels in plasma. The prominent localization of IMD in hypothalamus and pituitary and in kidney is consistent with a physiological role in the central and peripheral regulation of the circulation and water-electrolyte homeostasis. IMD is a potent systemic and pulmonary vasodilator, influences regional blood flow and augments cardiac contractility. IMD protects myocardium from the deleterious effects of oxidative stress associated with ischaemia-reperfusion injury and exerts an anti-growth effect directly on cardiomyocytes to oppose the influence of hypertrophic stimuli. The robust increase in expression of the peptide in hypertrophied and ischaemic myocardium indicates an important protective role for IMD as an endogenous counter-regulatory peptide in the heart.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The self-compression of a relativistic Gaussian laser pulse propagating in a non-uniform plasma is investigated. A linear density inhomogeneity (density ramp) is assumed in the axial direction. The nonlinear Schrodinger equation is first solved within a one-dimensional geometry by using the paraxial formalism to demonstrate the occurrence of longitudinal pulse compression and the associated increase in intensity. Both longitudinal and transverse self-compression in plasma is examined for a finite extent Gaussian laser pulse. A pair of appropriate trial functions, for the beam width parameter (in space) and the pulse width parameter (in time) are defined and the corresponding equations of space and time evolution are derived. A numerical investigation shows that inhomogeneity in the plasma can further boost the compression mechanism and localize the pulse intensity, in comparison with a homogeneous plasma. A 100 fs pulse is compressed in an inhomogeneous plasma medium by more than ten times. Our findings indicate the possibility for the generation of particularly intense and short pulses, with relevance to the future development of tabletop high-power ultrashort laser pulse based particle acceleration devices and associated high harmonic generation. An extension of the model is proposed to investigate relativistic laser pulse compression in magnetized plasmas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coherent wake emission is a unique source of extreme ultraviolet radiation and has been recently shown to provide the basis for intense attosecond light. Here we present a novel scheme, supported by particle-in-cell simulations, demonstrating that enhancement and spectral control of the coherent wake emission signal can be achieved by modifying the interaction plasma density ramp. Significant tunable enhancement of harmonic emission is verified experimentally, with factors of > 50 in relative signal increase achieved in a narrow band of harmonics at the cutoff frequency.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using a unique set of data and exploiting a large-scale natural experiment, we estimate the effect of real-time usage information on residential electricity consumption in Northern Ireland. Starting in April 2002, the utility replaced prepayment meters with advanced meters that allow the consumer to track usage in real-time. We rely on this event, account for the endogeneity of price and payment plan with consumption through a plan selection correction term, and find that the provision of information is associated with a decline in electricity consumption of 11-17%. We find that the reduction is robust to different specifications, selection-bias correction methods and subsamples of the original data. The advanced metering program delivers reasonably cost-effective reductions in carbon dioxide emissions, even under the most conservative usage reduction scenarios.