5 resultados para Predicate Transformers

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design of a novel 8-way power-combining transformer for use in mm-wave power amplifier (PA). The combiner exhibits a record low insertion loss of 1.25 dB at 83.5 GHz. A complete circuit comprised of a power splitter, two-stage cascode PA array, a power combiner and input/output matching elements was designed and realized in SiGe technology. Measured gain of at least 16.8 dB was obtained from 76.4 GHz to 85.3 GHz with a peak 19.5 dB at 83 GHz. The prototype delivered 12.5 dBm OP and 14 dBm saturated output power when operated from a 3.2 V DC supply voltage at 78 GHz. © 2013 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A BSP (Bulk Synchronous Parallelism) computation is characterized by the generation of asynchronous messages in packages during independent execution of a number of processes and their subsequent delivery at synchronization points. Bundling messages together represents a significant departure from the traditional ‘one communication at a time’ approach. In this paper the semantic consequences of communication packaging are explored. In particular, the BSP communication structure is identified with a general form of substitution—predicate substitution. Predicate substitution provides a means of reasoning about the synchronized delivery of asynchronous communications when the immediate programming context does not explicitly refer to the variables that are to be updated (unlike traditional operations, such as the assignment $x := e$, where the names of the updated variables can be extracted from the context). Proofs of implementations of Newton's root finding method and prefix sum are used to illustrate the practical application of the proposed approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental assessments of the modified power-combining Class-E amplifier are described. The technique used to combine the output of individual power amplifiers (PAs) into an unbalanced load without the need for bulky transformers permits the use of small RF chokes useful for the deployment in the EER transmitter. The modified output load network of the PA results in excellent 50 dBc and 46 dBc second and third-harmonic suppressions, dispensing the need for additional lossy filtering block. Operating from a 3.2 V dc supply voltage, the PA exhibits 64% drain efficiency at 24 dBm output power. Over a wide bandwidth of 350 MHz, drain efficiency of better than 60% at output power higher than 22 dBm were achieved. © 2010 IEICE Institute of Electronics Informati.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Much of the bridge stock on major transport links in North America and Europe was constructed in the 1950s and 1960s and has since deteriorated or is carrying loads far in excess of the original design loads. Structural Health Monitoring Systems (SHM) can provide valuable information on the bridge capacity but the application of such systems is currently limited by access and bridge type. This paper investigates the use of computer vision systems for SHM. A series of field tests have been carried out to test the accuracy of displacement measurements using contactless methods. A video image of each test was processed using a modified version of the optical flow tracking method to track displacement. These results have been validated with an established measurement method using linear variable differential transformers (LVDTs). The results obtained from the algorithm provided an accurate comparison with the validation measurements. The calculated displacements agree within 2% of the verified LVDT measurements, a number of post processing methods were then applied to attempt to reduce this error.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Much of the bridge stock on major transport links in North America and Europe was constructed in the 1950’s and 1960’s and has since deteriorated or is carrying loads far in excess of the original design loads. Structural Health Monitoring Systems (SHM) can provide valuable information on the bridge capacity but the application of such systems is currently limited by access and system cost. This paper investigates the development of a low cost portable SHM system using commercially available cameras and computer vision techniques. A series of laboratory tests have been carried out to test the accuracy of displacement measurements using contactless methods. The results from each of the tests have been validated with established measurement methods, such as linear variable differential transformers (LVDTs). A video image of each test was processed using two different digital image correlation programs. The results obtained from the digital image correlation methods provided an accurate comparison with the validation measurements. The calculated displacements agree within 4% of the verified measurements LVDT measurements in most cases confirming the suitability full camera based SHM systems