41 resultados para Poultry inspection

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A survey was carried out on the occurrence of dinitrocarbanilide (DNC), the marker residue for nicarbazin, in poultry produced in Ireland during 2002-2004. Liver (n = 736) and breast muscle samples (n = 342) were tested. DNC residues were found in 40 and 26% of liver and breast muscle samples at levels greater than 12.5 and 5 mu g kg(-1), respectively. DNC residues were found at >200 mu g kg(-1) in 12 and 0% of liver and muscle samples, respectively. Samples of breast muscle (n = 217) imported from 11 countries were also tested for DNC residues. A lower incidence of DNC residues (6%) was found in imported breast muscle. Egg samples (n = 546) were tested and DNC residues were found in nine samples, with levels ranging between 14 and 122 mu g kg(-1). Analysis of poultry, carried out as part of official food inspection in the period 2004-2006, indicated a reduction in the number of broiler liver samples containing DNC at >200 mu g kg(-1), to approximately 7%. Low levels of DNC residues continue to be found in

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concentrations of the coccidiostat nicarbazin as low as 2 mg/kg in feed can result in violative drug residues arising in poultry liver. A lateral flow device (LFD) was developed for the detection of contaminating concentrations of nicarbazin following solvent extraction of poultry feeds. Test results, as determined by both visual and instrumental measurement, are available within minutes. For 22 feed samples, nicarbazin-free and fortified at 2 mg/kg, the % relative inhibition ranged from 0 to 45% and from 53 to 85%, respectively. Nicarbazin contamination at the critical concentration (2 mg/kg) can be determined in all cases providing the sampling is representative. A wide range of feed samples taken at a mill that incorporated nicarbazin into poultry feed were analyzed. Data generated for these samples by both the LFDs and a mass spectrometric method were compared, and a significant correlation was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents research for developing a virtual inspection system that evaluates the dimensional tolerance of forged aerofoil blades formed using the finite element (FE) method. Conventional algorithms adopted by modern coordinate measurement processes have been incorporated with the latest free-form surface evaluation techniques to provide a robust framework for the dimensional inspection of FE aerofoil models. The accuracy of the approach had been verified with a strong correlation obtained between the virtual inspection data and coordinate measurement data from corresponding aerofoil components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monensin, a carboxylic acid ionophore, is commonly fed to poultry to control coccidiosis. A method for rapid analysis of unextracted poultry plasma samples has been developed based on a novel immunoassay format: one-step all-in-one dry reagent time resolved fluorimetry. All assay specific components were pre-dried onto microtitration plate wells. Only addition of the serum sample diluted in assay buffer was required to perform analysis. Results were available one hour after sample addition. The limit of detection (mean + 3s) of the assay calculated from the analysis of 23 known negative samples was 14.2 ng ml(-1). Intra- and inter-assay RSD were determined as 15.2 and 7.4%, respectively, using a plasma sample fortified with 50 ng ml(-1) monensin. Eight broiler chickens were fed monensin at a dose rate of 120 mg kg(-1) feed for one week, blood sampled then slaughtered without drug withdrawal. Plasma monensin concentrations, as determined by the fluoroimmunoassay ranged from 101-297 ng ml(-1). This compared with monensin liver concentrations, determined by LC-MS, which ranged fi om 13-41 ng g(-1). The fluoroimmunoassay described is extremely user friendly, gives particularly rapid results and is suitable for the detection and quantification of plasma monensin residues. Data from medicated poultry suggest that analysis of plasma may be useful in predicting the extent of monensin liver residues.