9 resultados para Polylogarithmes multiples
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Building on a body of previous research by the author and colleagues in relation to multiple adverse childhood experiences (MACE), this paper addresses the question of ‘why multiples matter’ in relation to issues of cumulative adversity. Illustrative evidence is drawn from three research domains, epidemiology, multiple services use and child maltreatment to demonstrate the collective weight of evidence to suggest a targeting of those children and families experiencing multiple adversities to diminish the effects of such adversities realised across the life-course. Whilst the history of previous largely unsuccessful attempts to widen the range of children prioritised for intervention by child and family social workers might lead to pessimism in relation to their ability to respond to a MACE informed public health agenda, there are clear possibilities for developing agency structures, assessment tools and social work practices directed toward meeting the needs of those sub populations already prioritised by social workers: namely Children in Need, Children in need of Protection and Looked after Children.
Resumo:
This paper discusses the issues of parents and nurses when mulitples are admitted to busy NICU's
Resumo:
A search for the body of a victim of terrorist abduction and murder was made in a graveyard on the periphery of a major conurbation in Northern Ireland. The area is politically sensitive and the case of high profile. This required non-invasive, completely non-destructive and rapid assessment of the scene. A MALA RAMAC ground-penetrating radar system was used to achieve these objectives. Unprocessed and processed 400MHz data shows the presence of a collapse feature above and around a known 1970s burial with no similar collapse above the suspect location. In the saturated, clay-rich sediments of the site, 200MHz data offered no advantage over 400MHz data. Unprocessed 100MHz data shows a series of multiples in the known burial with no similar features in the suspect location. Processed 100MHz lines defined the shape of the collapse around the known burial to 2m depth, together with the geometry of the platform (1m depth) the gravedigger used in the 1970s to construct the site. In addition, processed 100MHz data showed both the dielectric contrast in and internal reflection geometry of the soil imported above the known grave. Thus the sequence, geometry, difference in infill and infill direction of the grave was reconstructed 30 years after burial. The suspect site showed no evidence of shallow or deep inhumation. Subsequently, the missing person������¢���¯���¿���½���¯���¿���½s body was found some distance from this site, vindicating the results and interpretation from ground-penetrating radar. The acquisition, processing, collapse feature and sequence stratigraphic interpretation of the known burial and empty (suspect) burial site may be useful proxies for other, similar investigations. GPR was used to evaluate this site within 3 hours of the survey commencing, using unprocessed data. An additional day of processing established that the suspect body did not reside here, which was counter to police and community intelligence.
Resumo:
We treat the question of existence of common hypercyclic vectors for families of continuous linear operators. It is shown that for any continuous linear operator T on a complex Fréchet space X and a set ? ? R+ × C which is not of zero three-dimensional Lebesgue measure, the family {a T + b I : (a, b) ? ?} has no common hypercyclic vectors. This allows to answer negatively questions raised by Godefroy and Shapiro and by Aron. We also prove a sufficient condition for a family of scalar multiples of a given operator on a complex Fréchet space to have a common hypercyclic vector. It allows to show that if D = {z ? C : | z | < 1} and f ? H8 (D) is non-constant, then the family {z Mf{star operator} : b- 1 < | z | < a- 1} has a common hypercyclic vector, where Mf : H2 (D) ? H2 (D), Mf f = f f, a = inf {| f (z) | : z ? D} and b = sup {| f (z) | : | z | ? D}, providing an affirmative answer to a question by Bayart and Grivaux. Finally, extending a result of Costakis and Sambarino, we prove that the family {a Tb : a, b ? C {set minus} {0}} has a common hypercyclic vector, where Tb f (z) = f (z - b) acts on the Fréchet space H (C) of entire functions on one complex variable.
Resumo:
Les vies et les carrières d’André Chamson et d’André Malraux se ressemblent par de multiples aspects. Contemporains, ils se connaissaient bien, menaient souvent les mêmes combats, souffraient des mêmes préoccupations, Mais c’est surtout par rapport à l’esprit qui les animait, en tant que grandes personnalités marquantes du XXe siècle, que d’intéressants parallèles peuvent être établis entre eux, que nous pouvons avec profit examiner les valeurs universelles et spirituelles qu’ils promouvaient, valeurs emblématiques pour tant de penseurs, d’acteurs, et d’écrivains de ce siècle. Ainsi pourrions-nous par ailleurs interroger et même évaluer la solidité, la résistance et le potentiel de telles valeurs pour le siècle à venir.
Resumo:
The overall aim of the work presented in this paper has been to develop Montgomery modular multiplication architectures suitable for implementation on modern reconfigurable hardware. Accordingly, novel high-radix systolic array Montgomery multiplier designs are presented, as we believe that the inherent regular structure and absence of global interconnect associated with these, make them well-suited for implementation on modern FPGAs. Unlike previous approaches, each processing element (PE) comprises both an adder and a multiplier. The inclusion of a multiplier in the PE means that the need to pre-compute or store any multiples of the operands is avoided. This also allows very high-radix implementations to be realised, further reducing the amount of clock cycles per modular multiplication, while still maintaining a competitive critical delay. For demonstrative purposes, 512-bit and 1024-bit FPGA implementations using radices of 2(8) and 2(16) are presented. The subsequent throughput rates are the fastest reported to date.
Resumo:
Intense, femtosecond laser interactions with blazed grating targets are studied through experiment and particle-in-cell (PIC) simulations. The high harmonic spectrum produced by the laser is angularly dispersed by the grating leading to near-monochromatic spectra emitted at different angles, each dominated by a single harmonic and its integer-multiples. The spectrum emitted in the direction of the third-harmonic diffraction order is measured to contain distinct peaks at the 9th and 12th harmonics which agree well with two-dimensional PIC simulations using the same grating geometry. This confirms that surface smoothing effects do not dominate the far-field distributions for surface features with sizes on the order of the grating grooves whilst also showing this to be a viable method of producing near-monochromatic, short-pulsed extreme-ultraviolet radiation.
Resumo:
Epitaxial SrBi2Ta2O9 (SBT) thin films with well-defined (001), (116), and (103) orientations have been grown by pulsed laser deposition on (001)-, (011)-, and (111)-oriented Nb-doped SrTiO3 substrates. X-ray diffraction pole figure and phi -scan measurements revealed that the three-dimensional epitaxial orientation relation SBT(001)parallel to SrTiO3(001), and SBT[1(1) over bar 0]parallel to SrTiO3[100] is valid for all cases of SET thin films on SrTiO3 substrates, irrespective of their orientations. Atomic force microscopy images of the c-axis-oriented SET revealed polyhedron-shaped grains showing spiral growth around screw dislocations. The terrace steps of the c-axis-oriented SET films were integral multiples of a quarter of the lattice parameter c of SBT (similar to 0.6 nm). The grains of (103)-oriented SET films were arranged in a triple-domain configuration consistent with the symmetry of the SrTiO3(111) substrate. The measured remanent polarization (2P(r)) and coercive field (2E(c)) of (116)-oriented SBT films were 9.6 muC/cm(2) and 168 kV/cm, respectively, for a maximum applied electric field of 320 kV/cm. Higher remanent polarization (2P(r)=10.4 muC/cm(2)) and lower coercive field (2E(c)=104 kV/cm) than those of SBT(116) films were observed in (103)-oriented SET thin films, and (001)-oriented SET revealed no ferroelectricity along the [001] axis. The dielectric constants of (001)-, (116)-, and (103)-oriented SBT were 133, 155, and 189, respectively. (C) 2000 American Institute of Physics.
Resumo:
Objectives: The purpose of this investigation was to determine for dispensed multiples (1 through 4) of powder (P) and liquid (L) in hand-mixed dental cement whether: (1) the mean (P/L) ratio (m/m) and (2) the maximum difference in (P/L) ratio is dependent on the number of multiples dispensed. The Null hypotheses were: (a) mean (P/L) ratio is independent of the number of multiples dispensed and (b) maximum difference in (P/L) ratio is independent of the number of multiples dispensed.
Methods: The materials investigated are listed in the Table. The masses of dispensed aliquots of powder and liquid were measured by a single operator (n=10, for multiples 1 through 4) on a 4-place analytical balance. All measurements were made independently and all possible (P/L) ratios calculated for each sample. The effect of multiple dispensations on (P/L) ratios and maximum (P/L) differences was by one-way ANOVA and linear regression, respectively, with the Tukey post-hoc correction for multiple comparisons.MULTIPLE DISPENSEDDISPENSED MU(x1)(x2)(x3)(x4)Zinc phosphateHeraeus12.271(0.691)a13.051(1.269)b13.215(0.824)b13.118(1.149)bFuji IXGC4.209(0.373)a4.085(0.275)b4.095(0.226)b4.095(0.217)bIRMDentsply7.933(0.767)a7.430(0.451)b7.977(0.729)a8.186(0.929)aKetac-Cem3M Espe9.6206(0.613)a9.714(0.523)a9.298(0.314)b9.321(0.292)bMean (SD) powder/liquid ratio (m/m). Superscript letters represent significances (α = 0.05) within each material
Results: Mean (SD) (P/L) ratios are presented in the Table. Null hypothesis (a) is rejected: either (x1) or (x2) dispensation yields a different (P/L) ratio to (x3) or (x4) (p < 0.05). Null hypothesis (b) is rejected: a negative correlation is observed in max (P/L) ratio difference with dispensed multiple for Ketac Cem (p = 0.029).
Conclusion: For hand-mixed dental cements: (1) more consistent (P/L) ratios may be observed with multiple dispensations of powder & liquid; (2) maximum differences in (P/L) ratio may be negatively correlated with dispensation multiple in some materials.