7 resultados para Pacing

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction : Insulation defects with externalized conductors have been reported in the St. Jude Riata(®) family of defibrillation leads (St. Jude Medical, Sylmar, CA, USA). The objective of the Northern Ireland Riata(®) lead screening program was to identify insulation defects and externalized conductors by systematic fluoroscopic and electrical assessment in a prospectively defined cohort of patients. We sought to estimate the prevalence, identify risk factors, and determine the natural history of this abnormality. Methods : All patients with a Riata(®) lead under follow-up at the Royal Victoria Hospital were invited for fluoroscopic imaging and implantable cardioverter-defibrillator lead parameter checks. Fluoroscopic images were read independently by two cardiologists and the presence of externalized conductors was classified as positive, negative, or borderline. Results: One hundred and sixty-five of 212 patients with a Riata lead were evaluated by fluoroscopy and lead parameter measurements. The mean duration after implantation was 3.98+/-1.43 years. After screening 25 (15%) patients were classified as positive, 137 (83%) negative, and three (1.8%) borderline. Time since implantation (P = 0.001), presence of a single coil lead (P = 0.042), and patient age (P = 0.034) were significantly associated with externalized conductors. The observed rate of externalized conductors was 26.9% for 8-French and 4.7% for 7-French leads. No leads that were identified prospectively with externalized conductors had electrical abnormalities. Seven of 25 (28%) patients had a defective lead extracted by the end of this screening period. Conclusion: A significant proportion (15%) of patients with a Riata lead had an insulation breach 4 years after implantation. High-resolution fluoroscopic imaging in at least two orthogonal views is required to identify this abnormality. (PACE 2012;35:1498-1504).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?

DESIGN: Animal study.

SETTING: University research laboratory.

SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.

INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).

MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).

CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to describe the perceptions of Long Term Care (LTC) service providers in urban Canadian care facilities regarding the prevalence and nature of resident behavior problems and how staff manage these problems. Key informants from 15 LTC facilities housing 1,928 residents, participated in a cross sectional survey which employed semi-structured telephone interviews. Respondents estimated that on average 61% (n = 1,176) of residents had some type of mental health/behavioral problem, with facility estimates ranging from 20% to 90%. The most frequently reported problem behaviors included: general agitation and restlessness (36%); pacing and aimless wandering (28%); hoarding things (24%); hitting either self or others (23%); and verbal aggression (22%). Behaviors reported by respondents as "disruptive" or "very disruptive" were screaming (13%), sexual disinhibition (10%), and hitting either self or others (10%). The most common interventions used by staff were behavioral interventions followed by the use of medications. Low levels of staffing and educational training of staff were among the most common factors recognized as contributing to the difficulty in caring for residents with mental health needs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intermedin/adrenomedullin-2 (IMD) is a member of the adrenomedullin/CGRP peptide family. Less is known about the distribution of IMD than for other family members within the mammalian cardiovascular system, particularly in humans. The aim was to evaluate plasma IMD levels in healthy subjects and patients with chronic heart failure. IMD and its precursor fragments, preproIMD25–56 and preproIMD57–92, were measured by radioimmunoassay in 75 healthy subjects and levels of IMD were also compared to those of adrenomedullin (AM) and mid-region proadrenomedullin45–92 (MRproAM45–92) in 19 patients with systolic heart failure (LVEF < 45%). In healthy subjects, plasma levels (mean + SE) of IMD (6.3 + 0.6 pg ml−1) were lower than, but correlated with those of AM (25.8 + 1.8 pg ml−1; r = 0.49, p < 0.001). Plasma preproIMD25–56 (39.6 + 3.1 pg ml−1), preproIMD57–92 (25.9 + 3.8 pg ml−1) and MRproAM45–92 (200.2 + 6.7 pg ml−1) were greater than their respective bioactive peptides. IMD levels correlated positively with BMI but not age, and were elevated in heart failure (9.8 + 1.3 pg ml−1, p < 0.05), similarly to MRproAM45–92 (329.5 + 41.9 pg ml−1, p < 0.001) and AM (56.8 + 10.9 pg ml−1, p < 0.01). IMD levels were greater in heart failure patients with concomitant renal impairment (11.3 + 1.8 pg ml−1) than those without (6.5 + 1.0 pg ml−1; p < 0.05). IMD and AM were greater in patients receiving submaximal compared with maximal heart failure drug therapy and were decreased after 6 months of cardiac resynchronization therapy. In conclusion, IMD is present in the plasma of healthy subjects less abundantly than AM, but is similarly correlated weakly with BMI. IMD levels are elevated in heart failure, especially with concomitant renal impairment, and tend to be reduced by high intensity drug or pacing therapy.