9 resultados para PINHOLE

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A scheme for producing collimated protons from laser interactions with a diamond-like-carbon+pinhole target is proposed. The process is based on radiation pressure acceleration in the multi-species light-sail regime [B. Qiao et al., Phys. Rev. Lett. 105, 155002 (2010); T. P. Yu et al., Phys. Rev. Lett. 105, 065002 (2010)]. Particle-in-cell simulations demonstrate that transverse quasistatic electric field at TV/m level can be generated in the pinhole. The transverse electric field suppresses the transverse expansion of protons effectively, resulting in a higher density and more collimated proton beam compared with a single foil target. The dependence of the proton beam divergence on the parameters of the pinhole is also investigated. 

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We demonstrate the multifolding Origami manufacture of elastically-deformable Distributed Bragg Reflector (DBR) membranes that reversibly color-tune across the full visible spectrum without compromising their peak reflectance. Multilayer films composed of alternating transparent rubbers are fixed over a 300 mu m wide pinhole and deformed by pressure into a concave shape. Pressure-induced color tuning from the near-IR to the blue arises from both changes in thickness of the constituent layers and from tilting of the curved DBR surfaces. The layer thickness and color distribution upon deformation, the band-gap variation and the repeatability of cyclic color tuning, are mapped through micro-spectroscopy. Such spatially-dependent thinning of the film under elastic deformation produces spatial chirps in the color, and are shown to allow reconstruction of complex 3D strain distributions. (C) 2012 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By using polycapillary lenses to focus laser-produced x-ray sources to high intensities, an improvement in signal-to-noise ratio can be achieved. Here the He-alpha line emission produced by driving a titanium backlighter target is focused by a polycapillary lens and the output characterized. The x-ray spot is measured to have a peak intensity of 4.5 x 10(7) photons, with a total photon count of 8.8 x 10(8) in 0.13 +/- 0.01 mm(2). This setup is equivalent to placing the backlighter target 3 mm from the sample with a 600 mu m diameter pinhole. The polycapillary lens enables the placement of the backlighter target at a much larger distance from the sample to be studied and therefore has the ability to greatly improve the signal-to-noise ratio on detectors. We demonstrate this with two simple diffraction experiments using pyrolytic graphite and polycrystalline aluminium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To assess the outcomes of cataract surgery performed by novice surgeons during training in a rural programme. Design: Retrospective study. Participants: Three hundred thirty-four patients operated by two trainees under supervision at rural Chinese county hospitals. Methods: Two trainees performed surgeries under supervision. Visual acuity, refraction and examinations were carried out 3 months postoperatively. Main Outcome Measures: Postoperative uncorrected visual acuity, pinhole visual acuity, causes of visual impairment (postoperative uncorrected visual acuity<6/18) Results: Among 518 operated patients, 426 (82.2%) could be contacted and 334 (64.4% of operated patients) completed the examinations. The mean age was 74.1±8.8 years and 62.9% were women. Postoperative uncorrected visual acuity was available in 372 eyes. Among them, uncorrected visual acuity was ≥6/18 in 278 eyes (74.7%) and <6/60 in 60 eyes (16.1%), and 323 eyes (86.8%) had pinhole visual acuity≥6/18 and 38 eyes (10.2%) had pinhole visual acuity<6/60. Main causes of visual impairment were uncorrected refractive error (63.9%) and comorbid eye disease (24.5%). Comorbid eye diseases associated with pinhole visual acuity<6/60 (n=23, 6.2%) included glaucoma, other optic nerve atrophy, vitreous haemorrhage and retinal detachment. Conclusions: The findings suggest that hands-on training remains safe and effective even when not implemented in centralized training centres. Further refinement of the training protocol, providing postoperative refractive services and more accurate preoperative intraocular lens calculations, can help optimize outcomes. © 2012 The Authors Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the prevalence and causes of visual impairment among Chinese children aged 3 to 6 years in Beijing. DESIGN: Population-based prevalence survey. METHODS: Presenting and pinhole visual acuity were tested using picture optotypes or, in children with pinhole vision < 6/18, a Snellen tumbling E chart. Comprehensive eye examinations and cycloplegic refraction were carried out for children with pinhole vision < 6/18 in the better-seeing eye. RESULTS: All examinations were completed on 17,699 children aged 3 to 6 years (95.3% of sample). Subjects with bilateral correctable low vision (presenting vision < 6/18 correctable to >or= 6/18) numbered 57 (0.322%; 95% confidence interval [CI], 0.237% to 0.403%), while 14 (0.079%; 95% CI, 0.038% to 0.120%) had bilateral uncorrectable low vision (best-corrected vision of < 6/18 and >or= 3/60), and 5 subjects (0.028%; 95% CI, 0.004% to 0.054%) were bilaterally blind (best-corrected acuity < 3/60). The etiology of 76 cases of visual impairment included: refractive error in 57 children (75%), hereditary factors (microphthalmos, congenital cataract, congenital motor nystagmus, albinism, and optic nerve disease) in 13 children (17.1 %), amblyopia in 3 children (3.95%), and cortical blindness in 1 child (1.3%). The cause of visual impairment could not be established in 2 (2.63%) children. The prevalence of visual impairment did not differ by gender, but correctable low vision was significantly (P < .0001) more common among urban as compared with rural children. CONCLUSION: The leading causes of visual impairment among Chinese preschool-aged children are refractive error and hereditary eye diseases. A higher prevalence of refractive error is already present among urban as compared with rural children in this preschool population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To examine differences between patients with cataract detected during screening and presenting to clinic in rural China. METHODS: Subjects were recruited from 27 screenings and an eye clinic in the same town. All had pinhole-corrected vision < or =6/18 in > or =1 eye due to ophthalmologist-diagnosed cataract. Subjects were administered a previously validated questionnaire on barriers to surgery in four areas: knowledge (K), perceptions of quality (Q), transportation (T), and cost (C). RESULTS: Screening group (SG; n = 120) and clinic group (CG; n = 120) participants did not differ from eligible, examined screening and clinic patients respectively in age, gender, or vision. SG participants were significantly more likely to be female (P = 0.002) and had a smaller housing area and less education (P < 0.001 for both) than those in the CG. Those in the CG were more likely to be blind (habitual VA < or = 6/60) in the better-seeing eye (P = 0.05) and more willing to undergo and pay for cataract surgery (P < 0.001 for both) than SG. In logistic regression models, SG subjects had significantly lower quality scores (P < 0.001) and better habitual vision (P = 0.02) than did CG participants, and SG subjects who agreed to cataract surgery (78.3%) had significantly higher knowledge scores (P < 0.001) than those who refused. DISCUSSION: Screening outreach has the potential to ameliorate disparities in access to cataract surgery in rural China, as it appears more likely to detect patients with cataract with gender-related, economic, educational, and attitudinal barriers to surgery. However, education may be needed to convince screening subjects to undergo surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Presbyopia limits activities of daily living, but population-based data from rural China are scarce. METHODS: A population-based, cross-sectional study was conducted in 2009 among all persons aged 40+ years in a rural area near Shenyang, China. Distance and near VA were measured using logMAR E charts. Individuals with pinhole-corrected distance vision ≥20/63 underwent detailed eye examination and near refraction. RESULTS: A total of 1008 (91.5%) respondents were examined (mean age, 58.4 ± 10.7 years for men, 56.8 ± 9.89 years for women). Women and older subjects were more likely to participate. The prevalence of functional presbyopia (near vision <20/50 [N8] improved by ≥1 line with correction) was 67.3% (95% confidence interval [CI], 64.30%-70.09%), increasing from 27.6% at 40 to 49 years of age to 81.8% at 60 to 69 years. Multivariate analysis showed that older age (P < 0.001), but not gender or education, was significantly associated with a higher risk of presbyopia. Self-reported presbyopic spectacle correction coverage was 51.5%. In multivariate logistic regression models, worse presenting near vision (P = 0.013) and higher required spherical equivalent power (P < 0.001) were associated with having correction, while age, gender, education, and distance vision were unassociated. Major barriers reported by persons without near correction included poor quality of available glasses (33.1%) and lack of awareness of the condition and its treatment (28.8%). CONCLUSIONS: Presbyopia is highly prevalent in rural China, and nearly half of affected persons have no access to correction. Interventions should focus on education and improvement in the quality of refractive services.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ongoing developments in laser-driven ion acceleration warrant appropriate modifications to the standard Thomson Parabola Spectrometer (TPS) arrangement in order to match the diagnostic requirements associated to the particular and distinctive properties of laser-accelerated beams. Here we present an overview of recent developments by our group of the TPS diagnostic aimed to enhance the capability of diagnosing multi-species high-energy ion beams. In order to facilitate discrimination between ions with same Z / A , a recursive differential filtering technique was implemented at the TPS detector in order to allow only one of the overlapping ion species to reach the detector, across the entire energy range detectable by the TPS. In order to mitigate the issue of overlapping ion traces towards the higher energy part of the spectrum, an extended, trapezoidal electric plates design was envisaged, followed by its experimental demonstration. The design allows achieving high energy-resolution at high energies without sacrificing the lower energy part of the spectrum. Finally, a novel multi-pinhole TPS design is discussed, that would allow angularly resolved, complete spectral characterization of the high-energy, multi-species ion beams.