158 resultados para Open-pore polyurethane

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vertebroplasty is a minimally invasive surgical procedure, which requires efficacious percutaneous cement delivery via a cannulated needle to restore the strength and stiffness in osteoporotic vertebral bodies. Cement viscosity is understood to influence the injectability, cohesion and cement retention within the vertebral body. Altering the liquid to powder ratio modifies the viscosity of bone cement; however, the cement viscosity-response association between cement fill and augmentation of strength and stiffness is unknown. The aim of this study was to determine the relationship between viscosity, cement fill and the potential augmentation of strength and stiffness in an open pore foam structure that was representative of osteoporotic cancellous bone using an in vitro prophylactic vertebroplasty model. The results showed a strong linear correlation between compressive strength and stiffness augmentation with percentage cement fill, the extent of which was strongly dependent on the cement viscosity. Significant forces were required to ensure maximum delivery of the high viscosity cement using a proprietary screw-driven cement delivery technology. These forces could potentially exceed the normal human physical limit. Similar trends were observed when comparing the results from this study and previously reported cadaveric and animal based in vitro models.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A three-dimensional (3D) graphene-Co3O4 electrode was prepared by a two-step method in which graphene was initially deposited on a Ni foam with Co3O4 then grown on the resulting graphene structure. Cross-linked Co3O4 nanosheets with an open pore structure were fully and vertically distributed throughout the graphene skeleton. The free-standing and binder-free monolithic electrode was used directly as a cathode in a Li-O2 battery. This composite structure exhibited enhanced performance with a specific capacity of 2453 mA h g-1 at 0.1 mA cm-2 and 62 stable cycles with 583 mA h g-1 (1000 mA h gcarbon-1). The excellent electrochemical performance is associated with the unique architecture and superior catalytic activity of the 3D electrode. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Barnacles are a good model organism for the study of open populations with space-limited recruitment. These models are applicable to other species with open supply of new individuals and resource limitation. The inclusion of space in models leads to reductions in recruitment with increasing density, and thus predictions of population size and stability are possible. 2. Despite the potential generality of a demographic theory for open space-limited populations, the models currently have a narrow empirical base. In this study, a model for an open population with space-limited recruitment was extended to include size-specific survival and promotions to any size class. The assumptions of this model were tested using data from a pan-European study of the barnacle Chthamalus montagui Southward. Two models were constructed: a 6-month model and a periodic annual model. Predicted equilibria and their stabilities were compared between shores. 3. Tests of model assumptions supported the extension of the theory to include promotions to any size class. Mortality was found to be size-specific and density independent. Studied populations were open, with recruitment proportional to free space. 4. The 6-month model showed a significant interaction between time and location for equilibrium free space. This may have been due to contrasts in the timing of structuring processes (i.e. creating and filling space) between Mediterranean and Atlantic systems. Integration of the 6-month models into a periodic annual model removed the differences in equilibrium-free space between locations. 5. Model predictions show a remarkable similarity between shores at a European scale. Populations were persistent and all solutions were stable. This reflects the apparent absence of density-dependent mortality and a high adult survivorship in C. montagui. As populations are intrinsically stable, observations of fluctuations in density are directly attributable to variations in the environmental forcing of recruitment or mortality

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the emerging use of diamond-like carbon (DLC) as a coating for medical devices, few studies have examined the resistance of DLC coatings onto medical polymers to both microbial adherence and encrustation. In this study, amorphous DLC of a range of refractive indexes (1.7-1.9) and thicknesses (100-600 nm) was deposited onto polyurethane, a model polymer, and the resistance to microbial adherence (Escherichia coli; clinical isolate) and encrustation examined using in vitro models. In comparison to the native polymer, the advancing and receding contact angles of DLC-coated polyurethane were lower, indicating greater hydrophilic properties. No relationship was observed between refractive index, thickness, and advancing contact angle, as determined using multiple correlation analysis. The resistances of the various DLC-coated polyurethane films to encrustation and microbial adherence were significantly greater than that to polyurethane; however, there were individual differences between the resistances of the various DLC coatings. In general, increasing the refractive index of the coatings (100 nm thickness) decreased the resistance of the films to both hydroxyapatite and struvite encrustation and to microbial adherence. Films of lower thicknesses (100 and 200 nm; of defined refractive index, 1.8), exhibited the greatest resistance to encrustation and to microbial adherence. In conclusion, this study has uniquely illustrated both the microbial antiadherence properties and resistance to urinary encrustation of DLC-coated polyurethane. The resistances to encrustation and microbial adherence were substantial, and in light of this, it is suggested that DLC coatings of low thickness and refractive index show particular promise as coatings of polymeric medical devices. (c) 2006 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the effectiveness and tolerability of galantamine in patients with mild-to-moderate Alzheimer's disease (AD) in everyday clinical practice. Patient selection was made on 36 sequential patients attending Belfast City Hospital Memory Clinic between December 2000 and June 2001. Patients were treated with galantamine for 6 months, starting from 4 mg twice daily increasing to 8 mg twice daily and then to 12 mg twice daily at 4-weekly intervals. Patients (25 females, 11 males), mean age 78 years (59-90), were diagnosed with probable AD and had a mini-mental state examination (MMSE) score of 10-26. Efficacy was assessed using the MMSE, neuropsychiatric inventory (NPI), neuropsychiatric inventory caregiver distress (NPI-D) scale and the Bristol activities of daily living (B-ADL) scale at baseline and after 3 and 6 months of treatment. Mean improvements were noted on all four measures of efficacy at 3 and 6 months; improvements were significant on the MMSE, NPI and NPI-D at 3 months and on the NPI-D at 6 months. Galantamine was overall well tolerated. The most common adverse events were gastrointestinal, particularly nausea. Four patients stopped treatment due to adverse events, and seven were stabilised on 8 mg twice daily as they were unable to tolerate the target dose. This naturalistic study confirms clinical trial data, which shows galantamine improves cognition and behavioural symptoms and is overall well tolerated. © 2004 Blackwell Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To compare early (15 days) steroid therapy and dexamethasone with inhaled budesonide in very preterm infants at risk of developing chronic lung disease. METHODS: Five hundred seventy infants from 47 neonatal intensive care units were enrolled. Criteria for enrollment included gestational age 30%. Infants were randomly allocated to 1 of 4 treatment groups in a factorial design: early (15 days) dexamethasone, and delayed selective budesonide. Dexamethasone was given in a tapering course beginning with 0.50 mg/kg/day in 2 divided doses for 3 days reducing by half until 12 days of therapy had elapsed. Budesonide was administered by metered dose inhaler and a spacing chamber in a dose of 400 microg/kg twice daily for 12 days. Delayed selective treatment was started if infants needed mechanical ventilation and >30% oxygen for >15 days. The factorial design allowed 2 major comparisons: early versus late treatment and systemic dexamethasone versus inhaled budesonide. The primary outcome was death or oxygen dependency at 36 weeks and analysis was on an intention-to-treat basis. Secondary outcome measures included death or major cerebral abnormality, duration of oxygen treatment, and complications of prematurity. Adverse effects were also monitored daily. RESULTS: There were no significant differences among the groups for the primary outcome. Early steroid treatment was associated with a lower primary outcome rate (odds ratio [OR]: 0.85; 95% confidence interval [CI]: 0.61,1.18) but even after adjustment for confounding variables the difference remained nonsignificant. Dexamethasone-treated infants also had a lower primary outcome rate (OR: 0.86; 95% CI: 0.62,1.20) but again this difference remained not significant after adjustment. For death before discharge, dexamethasone and early treatment had worse outcomes than budesonide and delayed selective treatment (OR: 1.42; 95% CI: 0.93,2.16; OR: 1.51; 95% CI: 0.99,2.30 after adjustment, respectively) with the results not quite reaching significance. Duration of supplementary oxygen was shorter in the early dexamethasone group (median: 31 days vs 40-44 days). Early dexamethasone was also associated with increased weight loss during the first 12 days of treatment (52 g vs 3 g) compared with early budesonide, but over 30 days there was no difference. In the early dexamethasone group, there was a reduced incidence of persistent ductus arteriosus (34% vs 52%-59%) and an increased risk of hyperglycemia (55% vs 29%-34%) compared with the other 3 groups. Dexamethasone was associated with an increased risk of hypertension and gastrointestinal problems compared with budesonide but only the former attained significance. CONCLUSIONS: Infants given early treatment and dexamethasone therapy had improved survival without chronic lung disease at 36 weeks compared with those given delayed selective treatment and inhaled budesonide, respectively, but results for survival to discharge were in the opposite direction; however, none of these findings attained statistical significance. Early dexamethasone treatment reduced the risk of persistent ductus arteriosus. Inhaled budesonide may be safer than dexamethasone, but there is no clear evidence that it is more or less effective