49 resultados para OBSERVER

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

First-order time remaining until a moving observer will pass an environmental element is optically specified in two different ways. The specification provided by global tau (based on the pattern of change of angular bearing) requires that the element is stationary and that the direction of motion is accurately detected, whereas the specification provided by composite tau (based on the patterns of change of optical size and optical distance) does not require either of these. We obtained converging evidence,for our hypothesis. that observers are sensitive to composite tau in four experiments involving, relative judgments of, time to, passage with forced-choice methodology. Discrimination performance was enhanced in the presence of a local expansion component, while being unaffected when the detection of the direction of heading was impaired. Observers relied on the information carried in composite tau rather than on the information carried in its constituent components. Finally, performance was similar under conditions of observer motion and conditions of object motion. Because composite tau specifies first-order time remaining for a large number of situations, the different ways in which it may be detected are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To determine the agreement between observers in estimating the configuration of the human anterior chamber angle (ACA) using ultrasound biomicroscopy (UBM). Methods. Two masked clinicians used UBM images to estimate, in 41 eyes, the configuration of the ACA, especially (1) the position of contact between the peripheral iris and the inside of the eye wall, (2) the angularity of the approach to the ACA, and (3) the curvature of the peripheral iris. Agreement between observers was evaluated by the kappa statistic. Results. Inter-observer agreement in assessing the iris insertion (kappa = 0.79), angular width (Kappa = 0.95), and the peripheral iris curvature (kappa = 0.84) was high. Conclusions. The agreement between observers in evaluating the anterior chamber angle configuration by UBM was excellent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The histological grading of cervical intraepithelial neoplasia (CIN) remains subjective, resulting in inter- and intra-observer variation and poor reproducibility in the grading of cervical lesions. This study has attempted to develop an objective grading system using automated machine vision. The architectural features of cervical squamous epithelium are quantitatively analysed using a combination of computerized digital image processing and Delaunay triangulation analysis; 230 images digitally captured from cases previously classified by a gynaecological pathologist included normal cervical squamous epithelium (n = 30), koilocytosis (n = 46), CIN 1 (n = 52), CIN 2 (n = 56), and CIN 3 (n=46). Intra- and inter-observer variation had kappa values of 0.502 and 0.415, respectively. A machine vision system was developed in KS400 macro programming language to segment and mark the centres of all nuclei within the epithelium. By object-oriented analysis of image components, the positional information of nuclei was used to construct a Delaunay triangulation mesh. Each mesh was analysed to compute triangle dimensions including the mean triangle area, the mean triangle edge length, and the number of triangles per unit area, giving an individual quantitative profile of measurements for each case. Discriminant analysis of the geometric data revealed the significant discriminatory variables from which a classification score was derived. The scoring system distinguished between normal and CIN 3 in 98.7% of cases and between koilocytosis and CIN 1 in 76.5% of cases, but only 62.3% of the CIN cases were classified into the correct group, with the CIN 2 group showing the highest rate of misclassification. Graphical plots of triangulation data demonstrated the continuum of morphological change from normal squamous epithelium to the highest grade of CIN, with overlapping of the groups originally defined by the pathologists. This study shows that automated location of nuclei in cervical biopsies using computerized image analysis is possible. Analysis of positional information enables quantitative evaluation of architectural features in CIN using Delaunay triangulation meshes, which is effective in the objective classification of CIN. This demonstrates the future potential of automated machine vision systems in diagnostic histopathology. Copyright (C) 2000 John Wiley and Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report here the first detection of hectometer-size objects by the method of serendipitous stellar occultation. This method consists of recording the diffraction shadow created when an object crosses the observer's line of sight and occults the disk of a background star. One of our detections is most consistent with an object between Saturn and Uranus. The two other diffraction patterns detected are caused by Kuiper Belt objects beyond 100 AU from the Sun and hence are the farthest known objects in the solar system. These detections show that the Kuiper Belt is much more extended than previously believed and that the outer part of the disk could be composed of smaller objects than the inner part. This gives critical clues to understanding the problem of the formation of the outer planets of the solar system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to test whether a constant bearing angle strategy could account for the displacement regulations produced by a moving observer when attempting to intercept a ball following a curvilinear path. The participants were asked to walk through a virtual environment and to change, if (deemed) necessary, their walking speed so as to intercept a moving ball that followed either a rectilinear or a curvilinear path. The results showed that ball path curvature did indeed influence the participants' displacement kinematics in a way that was predicted by adherence to a constant bearing angle strategy mode of control. Velocity modifications were found to be proportional to the magnitude of target curvature with opposing curvatures giving rise to mirror displacement velocity changes. The role of prospective strategies in the control of interceptive action is discussed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Summary Target-controlled infusion systems have been shown to result in the administration of larger doses of propofol, which may result in delayed emergence and recovery from anaesthesia. The aim of this study was to investigate if this was due to a difference in the depth of hypnosis (using the bispectral index monitoring) between the manual and target controlled systems of administration. Fifty unpremedicated patients undergoing elective surgery were randomly allocated to have their anaesthesia maintained with manual or target-controlled propofol infusion schemes. In both groups, the rate of propofol administration was adjusted according to the standard clinical criteria while bispectral index scores were recorded by an observer not involved in the delivery of anaesthesia. The total dose of propofol used was higher in the target controlled group (mean 9.9 [standard deviation 1.6] compared with 8.1 [1.0] mg.kg.h in the manual group [p

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper introduces an automated computer- assisted system for the diagnosis of cervical intraepithelial neoplasia (CIN) using ultra-large cervical histological digital slides. The system contains two parts: the segmentation of squamous epithelium and the diagnosis of CIN. For the segmentation, to reduce processing time, a multiresolution method is developed. The squamous epithelium layer is first segmented at a low (2X) resolution. The boundaries are further fine tuned at a higher (20X) resolution. The block-based segmentation method uses robust texture feature vectors in combination with support vector machines (SVMs) to perform classification. Medical rules are finally applied. In testing, segmentation using 31 digital slides achieves 94.25% accuracy. For the diagnosis of CIN, changes in nuclei structure and morphology along lines perpendicular to the main axis of the squamous epithelium are quantified and classified. Using multi-category SVM, perpendicular lines are classified into Normal, CIN I, CIN II, and CIN III. The robustness of the system in term of regional diagnosis is measured against pathologists' diagnoses and inter-observer variability between two pathologists is considered. Initial results suggest that the system has potential as a tool both to assist in pathologists' diagnoses, and in training.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although much is now known about eye movement detection, little is known about the higher cognitive processes involved in joint attention. We developed video stimuli which when watched, engender an experience of joint attention in the observer. This allowed us to compare an experience of joint attention to nonjoint attention within an fMRI scanning environment. Joint attention was associated with activity in the ventromedial frontal cortex, the left superior frontal gyrus (BA10), cingulate cortex, and caudate nuclei. The ventromedial frontal cortex has been consistently shown to be activated during mental state attribution tasks. BA10 may serve a cognitive integration function, which in this case seems to utilize a perception–action matching process. The activation we identified in BA10 overlaps with a location of increased grey matter density that we recently found to be associated with autistic spectrum disorder. This study therefore constitutes evidence that the neural substrate of joint attention also serves a mentalizing function. The developmental failure of this substrate in the left anterior frontal lobe may be important in the etiology of autistic spectrum disorder.