6 resultados para Non-commercial film distribution

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Examines the extent to which the approach of the EU and UK courts towards the enforcement of trade mark rights is contrary to the public interest in the sense that it diminishes non-commercial interests and the freedom of expression. Comments on the European Court of Justice ruling in Arsenal Football Club Plc v Reed (C-206/01) on whether the trade mark rights over the name ARSENAL prevented its use on unofficial merchandise as a sign of club affiliation. Assesses the sufficiency of the infringement exceptions provided by Directive 2008/95 (Trade Mark Directive) art.6.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ethanol adsorption-desorption isotherms on well-organized mesoporous silica and titania films with hexagonal pores structure were studied by ellipsometric porosimetry. The mesopore volume Was calculated from the change of the effective refractive index at the end points of the isotherm. An improved Derjaguin-Broekhoff-de Boer (IDBdB) model for cylindrical pores is proposed for the determination of the pore size. In this model, the disjoining pressure isotherms were obtained by measuring the thickness of the ethanol film on a non-porous film with the same chemical composition. This approach eliminates uncertainties related to the application of the statistical film thickness determined via t-plots in previous versions of the DBdB model. The deviation in the surface tension of ethanol in the mesopores from that of a flat interface was described by the Tolman parameter in the Gibbs-Tolman-Koening-Buff equation. A positive value of the Tolman parameter of 0.2 nm was found from the fitting of the desorption branch of the isotherms to the experimental data obtained by Low Angle X-ray Diffraction (LA-XRD) and Transmission Electron Microscopy (TEM) measurements in the range of pore diameters between 2.1 and 8.3 nm. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The propagation of ion acoustic shocks in nonthermal plasmas is investigated, both analytically and numerically. An unmagnetized collisionless electron-ion plasma is considered, featuring a superthermal (non-Maxwellian) electron distribution, which is modeled by a ?-(kappa) distribution function. Adopting a multiscale approach, it is shown that the dynamics of low-amplitude shocks is modeled by a hybrid Korteweg-de Vries-Burgers (KdVB) equation, in which the nonlinear and dispersion coefficients are functions of the ? parameter, while the dissipative coefficient is a linear function of the ion viscosity. All relevant shock parameters are shown to depend on ?: higher deviations from a pure Maxwellian behavior induce shocks which are narrower, faster, and of larger amplitude. The stability profile of the kink-shaped solutions of the KdVB equation against external perturbations is investigated. The spatial profile of the shocks is found to depend upon the dispersion and the dissipation term, and the role of the interplay between dispersion and dissipation is elucidated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

REMA is an interactive web-based program which predicts endonuclease cut sites in DNA sequences. It analyses Multiple sequences simultaneously and predicts the number and size of fragments as well as provides restriction maps. The users can select single or paired combinations of all commercially available enzymes. Additionally, REMA permits prediction of multiple sequence terminal fragment sizes and suggests suitable restriction enzymes for maximally discriminatory results. REMA is an easy to use, web based program which will have a wide application in molecular biology research. Availability: REMA is written in Perl and is freely available for non-commercial use. Detailed information on installation can be obtained from Jan Szubert (jan.szubert@gmail.com) and the web based application is accessible on the internet at the URL http://www.macaulay.ac.uk/rema. Contact: b.singh@macaulay.ac.uk. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to increase understanding of the mechanism and dominant drivers influencing phase separation during ram extrusion of calcium phosphate (CaP) paste for orthopaedic applications. The liquid content of extrudate was determined, and the flow of liquid and powder phases within the syringe barrel during extrusion were observed, subject to various extrusion parameters. Increasing the initial liquid-to-powder mass ratio, LPR, (0.4-0.45), plunger rate (5-20 mm/min), and tapering the barrel exit (45°-90°) significantly reduced the extent of phase separation. Phase separation values ranged from (6.22 ± 0.69 to 18.94 ± 0.69 %). However altering needle geometry had no significant effect on phase separation. From powder tracing and liquid content determination, static zones of powder and a non-uniform liquid distribution was observed within the barrel. Measurements of extrudate and paste LPR within the barrel indicated that extrudate LPR remained constant during extrusion, while LPR of paste within the barrel decreased steadily. These observations indicate the mechanism of phase separation was located within the syringe barrel. Therefore phase separation can be attributed to either; (1) the liquid being forced downstream by an increase in pore pressure as a result of powder consolidation due to the pressure exerted by the plunger or (2) the liquid being drawn from paste within the barrel, due to suction, driven by dilation of the solids matrix at the barrel exit. Differentiating between these two mechanisms is difficult; however results obtained suggest that suction is the dominant phase separation mechanism occurring during extrusion of CaP paste.