88 resultados para No conventional reservoir

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vaginal microbicides for the prevention of HIV transmission may be an important option for protecting women from infection. Incorporation of dapivirine, a lead candidate nonnucleoside reverse transcriptase inhibitor, into intravaginal rings (IVRs) for sustained mucosal delivery may increase microbicide product adherence and efficacy compared with conventional vaginal formulations. Twentyfour
healthy HIV-negative women 18–35 years of age were randomly assigned (1:1:1) to dapivirine matrix IVR, dapivirine reservoir IVR, or placebo IVR. Dapivirine concentrations were measured in plasma
and vaginal fluid samples collected at sequential time points over the 33-day study period (28 days of IVR use, 5 days of follow-up). Safety was assessed by pelvic/colposcopic examinations, clinical laboratory tests, and adverse events. Both IVR types were safe and well tolerated with similar adverse events observed in the placebo and dapivirine groups. Dapivirine from both IVR types was successfully distributed throughout the lower genital tract at concentrations over 4 logs greater than the EC50 against wild-type HIV-1 (LAI) in MT4 cells. Maximum concentration (Cmax) and area under the concentration–time curve (AUC) values were significantly higher with the matrix than reservoir IVR. Mean plasma concentrations of dapivirine were ,2 ng/mL. These findings suggest that IVR delivery of microbicides is a viable option meriting further study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxybutynin, a drug of choice in the treatment of urinary incontinence, has low oral bioavailability due to extensive first-pass metabolism. A toxic metabolite, N-desethyloxybutynin, has been linked to adverse reactions to oral oxybutynin. This study, therefore, reports on the design of an oxybutynin intravaginal ring (IVR) of reservoir design, comprising an oxybutynin silicone elastomer core encased in a non-medicated silicone sheath, manufactured by reaction injection moulding at 50oC. An unusually high initial burst release of oxybutynin (42.7 mg in 24 h) was observed in vitro with a full length core (100 mg drug loading), with subsequent non-zero order drug release. Use of fractional segment cores substantially reduced the burst effect, yielding linear cumulative drug release versus time plots from days 2 to 14. Thus, a 1/8 fractional segment core gave a 24 h burst of 11.28 mg oxybutynin and, thereafter, zero order release at the target dose of 5 mg/day over 14 days. Two oxybutynin cores, each 1/16 of full length, gave a greater release than a single 1/8 core, due to core segment end effects resulting in an increased surface area for release. The burst release was investigated by determining drug solubilities in the propan-1-ol product of elastomer condensation cure (390 mg/ml) and in the elastomer itself (13.9-20.21 mg/ml, by direct extraction and indirect thermal methods). These high oxybutynin solubilities were considered the major contributors to the burst effect. It was concluded that use of a fractional segment core would allow development of a suitable oxybutynin reservoir IVR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calibration is essential for interpretation of radiocarbon dates, especially when the 14C dates are compared to historical or climatic records with a different chronological basis. 14C ages of samples from the marine environment, such as shells or fish bones, or samples with a marine component, such as human bone in coastal regions, require an additional consideration because of the reservoir age of the ocean. While the pre-industrial global mean reservoir correction, R(t), is about 400 years, local variations (?R) can be several hundred years or more. ?R compilations on a global scale have been undertaken previously (Stuiver et al. 1986; Stuiver and Braziunas 1993), but have not been updated recently. Here we describe an on-line reservoir correction database accessed via mapping software. Rather than publishing a static ?R compilation, new data will be incorporated when it becomes available. The on-line marine reservoir correction database can be accessed at the website http://www.calib.org/.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free-radical polymerization of methyl methacrylate and styrene using conventional organic initiators in the room temperature ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate ([ C(4)mim][PF6]) is rapid and produces polymers with molecular weights up to 10x higher than from benzene; both polymerization and isolation of products were achieved without using VOCs, offering economic as well as environmental advantages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: Currently, optimal use of virtual simulation for all treatment sites is not entirely clear. This study presents data to identify specific patient groups for whom conventional simulation may be completely eliminated and replaced by virtual simulation. Sampling and method: Two hundred and sixty patients were recruited from four treatment sites (head and neck, breast, pelvis, and thorax). Patients were randomly assigned to be treated using the usual treatment process involving conventional simulation, or a treatment process differing only in the replacement of conventional plan verification with virtual verification. Data were collected on set-up accuracy at verification, and the number of unsatisfactory verifications requiring a return to the conventional simulator. A micro-economic costing analysis was also undertaken, whereby data for each treatment process episode were also collected: number and grade of staff present, and the time for each treatment episode. Results: The study shows no statistically significant difference in the number of returns to the conventional simulator for each site and study arm. Image registration data show similar quality of verification for each study arm. The micro-costing data show no statistical difference between the virtual and conventional simulation processes. Conclusions: At our institution, virtual simulation including virtual verification for the sites investigated presents no disadvantage compared to conventional simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: To compare external beam radiotherapy techniques for parotid gland tumours using conventional radiotherapy (RT), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT). To optimise the IMRT techniques, and to produce an IMRT class solution.Materials and methods: The planning target volume (PTV), contra-lateral parotid gland, oral cavity, brain-stem, brain and cochlea were outlined on CT planning scans of six patients with parotid gland tumours. Optimised conventional RT and 3DCRT plans were created and compared with inverse-planned IMRT dose distributions using dose-volume histograms. The aim was to reduce the radiation dose to organs at risk and improve the PTV dose distribution. A beam-direction optimisation algorithm was used to improve the dose distribution of the IMRT plans, and a class solution for parotid gland IMRT was investigated.Results: 3DCRT plans produced an equivalent PTV irradiation and reduced the dose to the cochlea, oral cavity, brain, and other normal tissues compared with conventional RT. IMRT further reduced the radiation dose to the cochlea and oral cavity compared with 3DCRT. For nine- and seven-field IMRT techniques, there was an increase in low-dose radiation to non-target tissue and the contra-lateral parotid gland. IMRT plans produced using three to five optimised intensity-modulated beam directions maintained the advantages of the more complex IMRT plans, and reduced the contra-lateral parotid gland dose to acceptable levels. Three- and four-field non-coplanar beam arrangements increased the volume of brain irradiated, and increased PTV dose inhomogeneity. A four-field class solution consisting of paired ipsilateral coplanar anterior and posterior oblique beams (15, 45, 145 and 170o from the anterior plane) was developed which maintained the benefits without the complexity of individual patient optimisation.Conclusions: For patients with parotid gland tumours, reduction in the radiation dose to critical normal tissues was demonstrated with 3DCRT compared with conventional RT. IMRT produced a further reduction in the dose to the cochlea and oral cavity. With nine and seven fields, the dose to the contra-lateral parotid gland was increased, but this was avoided by optimisation of the beam directions. The benefits of IMRT were maintained with three or four fields when the beam angles were optimised, but were also achieved using a four-field class solution. Clinical trials are required to confirm the clinical benefits of these improved dose distributions.