6 resultados para Network load

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Analysis and synthesis of the new Class-EF power amplifier (PA) are presented in this paper. The proposed circuit offers means to alleviate some of the major issues faced by existing Class-EF and Class-EF PAs, such as (1) substantial power losses due to parasitic resistance of the large inductor in the Class-EF load network, (2) unpredictable behaviour of practical lumped inductors and capacitors at harmonic frequencies, and (3) deviation from ideal Class-EF operation mode due to detrimental effects of device output inductance at high frequencies. The transmission-line load network of the Class-EF PA topology elaborated in this paper simultaneously satisfies the Class-EF optimum impedance requirements at fundamental frequency, second, and third harmonics as well as simultaneously providing matching to the circuit optimum load resistance for any prescribed system load resistance. Furthermore, an elegant solution using an open and short-circuit stub arrangement is suggested to overcome the problem encountered in the mm-wave IC realizations of the Class-EF PA load network due to lossy quarter-wave line. © 2010 IEICE Institute of Electronics Informati.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three-phase four-wire shunt active power filter for harmonic mitigation and reactive power compensation in power systems supplying nonlinear loads is presented. Three adaptive linear neurons are used to tackle the desired three-phase filter current templates. Another feedforward three-layer neural network is adopted to control the output filter compensating currents online. This is accomplished by producing the appropriate switching patterns of the converter's legs IGBTs. Adequate tracking of the filter current references is obtained by this method. The active filter injects the current required to compensate for the harmonic and reactive components of the line currents, Simulation results of the proposed active filter indicate a remarkable improvement in the source current waveforms. This is reflected in the enhancement of the unified power quality index defined. Also, the filter has exhibited quite a high dynamic response for step variations in the load current, assuring its potential for real-time applications

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a Radial Basis Function neural network based AVR is proposed. A control strategy which generates local linear models from a global neural model on-line is used to derive controller feedback gains based on the Generalised Minimum Variance technique. Testing is carried out on a micromachine system which enables evaluation of practical implementation of the scheme. Constraints imposed by gathering training data, computational load, and memory requirements for the training algorithm are addressed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the rapid expansion of the internet and the increasing demand on Web servers, many techniques were developed to overcome the servers' hardware performance limitation. Mirrored Web Servers is one of the techniques used where a number of servers carrying the same "mirrored" set of services are deployed. Client access requests are then distributed over the set of mirrored servers to even up the load. In this paper we present a generic reference software architecture for load balancing over mirrored web servers. The architecture was designed adopting the latest NaSr architectural style [1] and described using the ADLARS [2] architecture description language. With minimal effort, different tailored product architectures can be generated from the reference architecture to serve different network protocols and server operating systems. An example product system is described and a sample Java implementation is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Variations in the phase angle difference between a remote 11kV connected wind farm and the centre of Belfast during a typical working day are investigated in the paper. The results obtained using phasor measurement units (PMUs) are compared with the data generated using a PSS/E simulator configured to model the N.Ireland network. The study investigates the effect of changes in the load demand and the wind farm output power on the phase angles at various locations on the network. The paper finally describes how a major system disturbance on the All-Ireland network was monitored and analysed using PMUs located at Queen's University, Belfast and University College Dublin. ©2007 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heat pumps can provide domestic heating at a cost that is competitive with oil heating in particular. If the electricity supply contains a significant amount of renewable generation, a move from fossil fuel heating to heat pumps can reduce greenhouse gas emissions. The inherent thermal storage of heat pump installations can also provide the electricity supplier with valuable flexibility. The increase in heat pump installations in the UK and Europe in the last few years poses a challenge for low-voltage networks, due to the use of induction motors to drive the pump compressors. The induction motor load tends to depress voltage, especially on starting. The paper includes experimental results, dynamic load modelling, comparison of experimental results and simulation results for various levels of heat pump deployment. The simulations are based on a generic test network designed to capture the main characteristics of UK distribution system practice. The simulations employ DIgSlILENT to facilitate dynamic simulations that focus on starting current, voltage variations, active power, reactive power and switching transients.