28 resultados para Nd-Yag Laser

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thomson scattering is one of the most powerful diagnostic tools for plasma characterization, and it has been applied to a variety of plasmas. It is a nonintrusive technique, and the interpretation of the signal is relatively simple. However, this method has not been widely applied to low-temperature laser-ablated plasmas. Raman satellites have been observed in the scattering spectrum from a Mg laser-ablated plasma, giving this diagnostic the potential to be also used in density quantification of metastable states in plasmas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have obtained density and temperature informations on an expanding KrF laser-ablated magnesium plume via optical Thomson scatter with a frequency doubled Nd:YAG laser. The electron temperature was found to decay with the expected Te t-1 dependence. However, we have found the electron density to have a time dependence ne t-4.95 which can be explained by strong recombination processes. We also observed atomic Raman satellites originating from transitions between the different angular momentum levels of the metastable 3P0 term in Mg I.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Raman satellites have been observed in the scattering of a Nd:YAG laser (532 nm) from a laser-ablated Mg plasma plume. We identify them as originating from transitions between the fine-structure components of the metastable 3s3p P-3(0,1,2) level of Mg. We have calculated the cross sections for Raman and Rayleigh scattering from the metastable state. Comparison of the expected ratio of the satellites to the Rayleigh peak indicates the changing population fraction of the metastable states in the plume.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thomson scattering from laser-induced plasma in atmospheric helium was used to obtain temporally and spatially resolved electron temperature and density profiles. Electron density measurements at 5 s after breakdown are compared with those derived from the separation of the allowed and forbidden components of the 447.1 nm He I line. Plasma is created using 9 ns, 140 mJ pulses from Nd:YAG laser at 1064 nm. Electron densities of ~5 × 10 cm are in good agreement with Thomson scattering measurements, benchmarking this emission line as a useful diagnostic for high density plasmas. © 2011 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evidence of high gain pumped by recombination has been observed in the 5g-4f transition at 11.1 nn in sodiumlike copper ions with use of a 20-J 2-ps Nd:glass laser system. The time- and space-integrated gain coefficient was 8.8 +/- 1.4 cm(-1), indicating a single-transit amplification of similar to 60 times. This experiment has shown that 2 ps is the optimum pulse duration to drive the sodiumlike copper recombination x-ray lasing at 11.1 nm. (C) 1996 Optical Society of America

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Optical Thomson scattering has been implemented as a diagnostic of laser ablated plumes generated with second harmonic Nd:YAG laser radiation at 532 nm. Thomson scattering data with both spatial and temporal resolution has been collected, giving both electron density, and temperature distributions within the plume as a function of time. Although the spatial profiles do not match very well for simple models assuming either isothermal or isentropic expansion, consideration of the measured ablated mass indicates an isothermal expansion fits better than an isentropic expansion and indeed, at late time, the spatial profile of temperature is almost consistent with an isothermal approximation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have carried out optical Thomson scattering measurements from a laser induced breakdown in He at 1 atmosphere. The breakdown was created with a Nd:YAG laser with 9ns pulse duration and 400mJ pulse energy focused into a chamber filled with He. A second harmonic Nd: YAG laser with 9ns pulses and up to 80mJ energy was used to obtain temporally and spatially resolved data on the electron density and temperature. In parallel experiments, we measured the emission of the 447.1nm line from He I. Initial results suggest good agreement between densities inferred but full Abel inversion is needed for conclusive results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose. To evaluate the effects of a YAG laser posterior capsulotomy on intraocular pressure (IOP) in glaucoma patients. Methods. We retrospectively studied 69 patients who underwent posterior capsulotomy following cataract or combined cataract-glaucoma surgery and who had a minimum follow-up of six months. We assessed IOP control, number of glaucoma medications required, and need for additional glaucoma surgery following capsulotomy as clinical outcomes. We defined an "unfavorable result" as: a =5 mm Hg sustained rise in IOP, a need for additional glaucoma medications, and/or a need for additional glaucoma surgery. We calculated Kaplan-Meier event rate curves for these "unfavorable results." Mean follow-up was 24.4 ± 12.3 months. Results. 6.3% of patients had an IOP rise of =5 mm Hg one hour post capsulotomy. The actuarial (Kaplan-Meier) rate of any "unfavorable result" was 11.6% at 4 months, 38.1% at 12 months, 46.1% at 24 months, and 52.1% at 36 months following capsulotomy. Conclusions. Progression of glaucoma after YAG capsulotomy is common and may be accelerated by the laser procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report a case of malignant glaucoma after diode laser cyclophotocoagulation. METHOD: Case report. RESULTS: A 45-year-old man with uncontrolled secondary glaucoma in his right eye after corneoscleral graft and cataract extraction underwent diode laser cyclophotocoagulation. The right eye was aphakic, with an intact posterior capsule. Two weeks later, the patient presented with blurred vision, edematous cornea, and flat anterior chamber. The posterior capsule was touching the endothelium. Intraocular pressure was 20 mm Hg. Repeated Nd:YAG laser capsulotomy was effective in reversing the malignant glaucoma attack, and the anterior chamber deepened. CONCLUSION: Malignant glaucoma can occur after diode laser cyclophotocoagulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have used optical Rayleigh and Thomson scattering to investigate the expansion dynamics of laser induced plasma in atmospheric helium and to map its electron parameters both in time and space. The plasma is created using 9 ns duration, 140 mJ pulses from a Nd:YAG laser operating at 1064 nm, focused with a 10 cm focal length lens, and probed with 7 ns, 80 mJ, and 532 nm Nd:YAG laser pulses. Between 0.4 μs and 22.5 μs after breakdown, the electron density decreases from 3.3 × 1017 cm−3 to 9 × 1013 cm−3, while the temperature drops from 3.2 eV to 0.1 eV. Spatially resolved Thomson scattering data recorded up to 17.5 μs reveal that during this time the laser induced plasma expands at a rate given by R ∼ t0.4 consistent with a non-radiative spherical blast wave. This data also indicate the development of a toroidal structure in the lateral profile of both electron temperature and density. Rayleigh scattering data show that the gas density decreases in the center of the expanding plasma with a central scattering peak reemerging after about 12 μs. We have utilized a zero dimensional kinetic global model to identify the dominant particle species versus delay time and this indicates that metastable helium and the He2 + molecular ion play an important role.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One effective approach is to destroy industrial waste and pollution is the use of a semiconductor photocatalysis system. To date such, photocatalysis systems have employed conventional linear light sources. Initial results from a study of a photocatalysis system incorporating a tripled Nd:YAG laser are reported. The laser light not only played a roll as a light source for activating the photocatalyst(TiO2), but also destroyed the organic species directly via a photochemical process. The reaction intermediates and changes in their concentrations are monitored using HPLC. The relationship between the power of laser and kinetics of photoreaction are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spatially and temporally varying neutral, ion and electron number densities have been mapped out within laser ablated plasma plumes expanding into vacuum. Ablation of a magnesium target was performed using a KrF laser, 30 ns pulse duration and 248 nm wavelength. During the initial stage of plasma expansion (t <EQ 100 ns) interferometry has been used to obtain line averaged electron number densities, for laser power densities on target in the range 1.3 - 3.0 X 108 W/cm2. Later in the plasma expansion (t equals 1 microsecond(s) ) simultaneous absorption and laser induced fluorescence spectroscopy has been used to determine 3D neutral and ion number densities, for a power density equal to 6.7 X 107 W/cm2. Two distinct regions within the plume were identified. One is a fast component (approximately 106 cm-1) consisting of ions and neutrals with maximum number densities observed to be approximately 30 and 4 X 1012 cm-3 respectively, and the second consists of slow moving neutral material at a number density of up to 1015 cm-3. Additionally a Langmuir probe has been used to obtain ion and electron number densities at very late times in the plasma expansion (1 microsecond(s) <EQ t <EQ 15 microsecond(s) ). A copper target was ablated using a Nd:YAG laser, 7.5 ns duration and 532 nm (2 (omega) ) wavelength, with a power density on target equal to 6 X 108 W/cm2. Two regions within the plume with different velocities were observed. Within a fast component (approximately 3 X 106 cms-1) electron and ion number densities of the order 5 X 1012 cm-3 were observed and within the second slower component (approximately 106 cms-1) electron and ion number densities of the order 1 - 2 X 1013 cm-3 were determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: A peripheral iridotomy (PI) is the treatment of choice for pupillary block. In this study we investigated the effect of enlarging the size of a small PI on the anterior chamber angle in patients with angle closure using ultrasound biomicroscopy (UBM). Patients and Methods: Patients who had been treated with laser peripheral iridotomy for angle closure and were identified to have a small patent PI (<100 µm) with still appositionally closed anterior chamber angle were selected prospectively. The anterior chamber angle was assessed using UBM. The angle opening distance 500 µm from the scleral spur (AOD500) as well as the anterior and posterior chamber depth (ACD and PCD) 1000 µm from the scleral spur was measured. In addition, the ACD/PCD ratio was calculated. Afterwards, the PI was enlarged using an Nd: YAG laser and the UBM measurements were repeated as described above. Results: Six eyes of six patients were examined. After the enlargement of the PI the average AOD500 increased from 109 µm (±36) to 147 µm (±40) (p

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report on measurements of the saturated single frequency output of a Ge XXIII x-ray laser on the J=0-->1 transition at 19.6 nm from a refraction compensating double target driven by 150 J of energy from 75-ps Nd-glass laser pulses. The 19.6-nm line completely dominated the laser output. The output energy was measured to be 0.9 mJ in a beam of 6.6x30 mrad(2) divergence, corresponding to a conversion efficiency of 6 x 10(-6).