28 resultados para Methods: analytical

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: We aim to calculate the kinetic, magnetic, thermal, and total energy densities and the flux of energy in axisymmetric sausage modes. The resulting equations should contain as few parameters as possible to facilitate applicability for different observations. 

Methods: The background equilibrium is a one-dimensional cylindrical flux tube model with a piecewise constant radial density profile. This enables us to use linearised magnetohydrodynamic equations to calculate the energy densities and the flux of energy for axisymmetric sausage modes. 

Results: The equations used to calculate the energy densities and the flux of energy in axisymmetric sausage modes depend on the radius of the flux tube, the equilibrium sound and Alfvén speeds, the density of the plasma, the period and phase speed of the wave, and the radial or longitudinal components of the Lagrangian displacement at the flux tube boundary. Approximate relations for limiting cases of propagating slow and fast sausage modes are also obtained. We also obtained the dispersive first-order correction term to the phase speed for both the fundamental slow body mode under coronal conditions and the slow surface mode under photospheric conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report on our findings based on the analysis of observations of the Type II-L supernova LSQ13cuw within the framework of currently accepted physical predictions of core-collapse supernova explosions. LSQ13cuw was discovered within a day of explosion, hitherto unprecedented for Type II-L supernovae. This motivated a comparative study of Type II-P and II-L supernovae with relatively well-constrained explosion epochs and rise times to maximum (optical) light. From our sample of twenty such events, we find evidence of a positive correlation between the duration of the rise and the peak brightness. On average, SNe II-L tend to have brighter peak magnitudes and longer rise times than SNe II-P. However, this difference is clearest only at the extreme ends of the rise time versus peak brightness relation. Using two different analytical models, we performed a parameter study to investigate the physical parameters that control the rise time behaviour. In general, the models qualitatively reproduce aspects of the observed trends. We find that the brightness of the optical peak increases for larger progenitor radii and explosion energies, and decreases for larger masses. The dependence of the rise time on mass and explosion energy is smaller than the dependence on the progenitor radius. We find no evidence that the progenitors of SNe II-L have significantly smaller radii than those of SNe II-P.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bovine serum albumin (BSA) is a commonly used model protein in the development of pharmaceutical formulations. In order to assay its release from various dosage forms, either the bicinchoninic acid (BCA) assay or a more specific size-exclusion high performance liquid chromatography (SE-HPLC) method are commonly employed. However, these can give erroneous results in the presence of some commonly-used pharmaceutical excipients. We therefore investigated the ability of these methods to accurately determine BSA concentrations in pharmaceutical formulations that also contained various polymers and compared them with a new and compared with a new reverse-phase (RP)–HPLC technique. We found that the RP-HPLC technique was the most suitable method. It gave a linear response in the range of 0.5 -100 µg/ml with a correlation coefficient of 0.9999, a limit of detection of 0.11 µg/ml and quantification of 0.33 µg/ml. The performed ‘t’ test for the estimated and theoretical concentration indicated no significant difference between them providing the accuracy. Low % relative standard deviation values (0.8-1.39%) indicate the precision of the method. Furthermore, the method was used to quantify in vitro BSA release from polymeric freeze-dried formulations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article gives an extensive overview of the wide range of analytical procedures developed for the detection of amphenicol antibiotic residues (chloramphenicol, thiamphenicol, and florfenicol) in many different types of foodstuffs (milk, meat, eggs, honey, seafood). Screening methods such as microbial inhibition methods, antibody-based immunoassays using conventional and biosensor-based detection systems, and some methods based on alternative recognition systems are described. The relative advantages and disadvantages of these methods are discussed and compared. The current status and future trends and developments in the need for accurate and rapid detection of this group of antimicrobials are also discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes the trends in analytical techniques for the determination of trichothecene mycotoxins, namely deoxynivalenol, and T-2 and HT-2 toxins in cereals and cereal products with particular emphasis on screening and rapid approaches. The driving force behind the changing methodologies is mainly attributed to legislative demands. However, for commercial and governmental testing laboratories, the need to use validated official methods is ever increasing to ensure quality assurance of results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To analyse the currently existing methods to infer the extent of cellular DNA damage induced by ionizing radiation when the pulsed field gel electrophoresis (PFGE) technique is used.