In this study a broadly representative sample of clients in the City of Westminster, receiving Care in the Community for reasons of mental ill-health, were interviewed regarding their experiences of, and levels of satisfaction with, services provided. The results reveal the vulnerability of services users, the benefits of community care, the high regard the majority have for their helpers, the limitations imposed by scarce resources, and the negative effects of only loose co-ordination between health and social services. Respondents also provide a rich source of data on how services might be improved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To characterize the population pharmacokinetics of ranitidine in critically ill children and to determine the influence of various clinical and demographic factors on its disposition. Methods: Data were collected prospectively from 78 paediatric patients (n = 248 plasma samples) who received oral or intravenous ranitidine for prophylaxis against stress ulcers, gastrointestinal bleeding or the treatment of gastro-oesophageal reflux. Plasma samples were analysed using high-performance liquid chromatography, and the data were subjected to population pharmacokinetic analysis using nonlinear mixed-effects modelling. Results: A one-compartment model best described the plasma concentration profile, with an exponential structure for interindividual errors and a proportional structure for intra-individual error. After backward stepwise elimination, the final model showed a significant decrease in objective function value (-12.618; P <0.001) compared with the weight-corrected base model. Final parameter estimates for the population were 32.1lh for total clearance and 285l for volume of distribution, both allometrically modelled for a 70kg adult. Final estimates for absorption rate constant and bioavailability were 1.31h and 27.5%, respectively. No significant relationship was found between age and weight-corrected ranitidine pharmacokinetic parameters in the final model, with the covariate for cardiac failure or surgery being shown to reduce clearance significantly by a factor of 0.46. Conclusions: Currently, ranitidine dose recommendations are based on children's weights. However, our findings suggest that a dosing scheme that takes into consideration both weight and cardiac failure/surgery would be more appropriate in order to avoid administration of higher or more frequent doses than necessary.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This is the protocol for a review and there is no abstract. The objectives are as follows:

To assess the effects of weaning by protocol for invasively ventilated critically ill children.

To compare the total duration of invasive mechanical ventilation of critically ill children who are weaned using protocols versus usual (non-protocolized) practice.
To ascertain any differences between protocolized weaning and usual care in terms of mortality, adverse events, ICU length of stay, and quality of life.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background:Mechanical ventilation is a critical component of paediatric intensive care therapy. It is indicated when the patient’s spontaneous ventilation is inadequate to sustain life. Weaning is the gradual reduction of ventilatory support and the transfer of respiratory control back to the patient. Weaning may represent a large proportion of the ventilatory period. Prolonged ventilation is associated with significant morbidity, hospital cost, psychosocial and physical risks to the child and even death. Timely and effective weaning may reduce the duration of mechanical ventilation and may reduce the morbidity and mortality associated with prolonged ventilation. However, no consensus has been reached on criteria that can be used to identify when patients are ready to wean or the best way to achieve it.Objectives:To assess the effects of weaning by protocol on invasively ventilated critically ill children. To compare the total duration of invasive mechanical ventilation of critically ill children who are weaned using protocols versus those weaned through usual (non-protocolized) practice. To ascertain any differences between protocolized weaning and usual care in terms of mortality, adverse events, intensive care unit length of stay and quality of life.Search methods:We searched the Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library, Issue 10, 2012), MEDLINE (1966 to October 2012), EMBASE (1988 to October 2012), CINAHL (1982 to October 2012), ISI Web of Science and LILACS. We identified unpublished data in the Web of Science (1990 to October 2012), ISI Conference Proceedings (1990 to October 2012) and Cambridge Scientific Abstracts (earliest to October 2012). We contacted first authors of studies included in the review to obtain further information on unpublished studies or work in progress. We searched reference lists of all identified studies and review papers for further relevant studies. We applied no language or publication restrictions.Selection criteriaWe included randomized controlled trials comparing protocolized weaning (professional-led or computer-driven) versus non-protocolized weaning practice conducted in children older than 28 days and younger than 18 years.Data collection and analysis:Two review authors independently scanned titles and abstracts identified by electronic searching. Three review authors retrieved and evaluated full-text versions of potentially relevant studies, independently extracted data and assessed risk of bias.Main results:We included three trials at low risk of bias with 321 children in the analysis. Protocolized weaning significantly reduced total ventilation time in the largest trial (260 children) by a mean of 32 hours (95% confidence interval (CI) 8 to 56; P = 0.01). Two other trials (30 and 31 children, respectively) reported non-significant reductions with a mean difference of -88 hours (95% CI -228 to 52; P = 0.2) and -24 hours (95% CI -10 to 58; P = 0.06). Protocolized weaning significantly reduced weaning time in these two smaller trials for a mean reduction of 106 hours (95% CI 28 to 184; P = 0.007) and 21 hours (95% CI 9 to 32; P < 0.001). These studies reported no significant effects for duration of mechanical ventilation before weaning, paediatric intensive care unit (PICU) and hospital length of stay, PICU mortality or adverse events.Authors' conclusions:Limited evidence suggests that weaning protocols reduce the duration of mechanical ventilation, but evidence is inadequate to show whether the achievement of shorter ventilation by protocolized weaning causes children benefit or harm.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report research implicating nostalgia as an intrapersonal means of warding off the stigmatization of persons with mental illness. We hypothesized and found that nostalgia about an encounter with a person with mental illness improves attitudes toward the mentally ill. In Experiment 1, undergraduates who recalled an encounter with a mentally ill person while focusing on central (vs. peripheral) features of the nostalgia prototype reported a more positive outgroup attitude. This beneficial effect of nostalgia was mediated by greater inclusion of the outgroup in the self (IOGS). In Experiment 2, undergraduates who recalled a nostalgic (vs. ordinary) interaction with a mentally ill person subsequently showed a more positive outgroup attitude. Results supported a serial mediation model whereby nostalgia increased social connectedness, which predicted greater IOGS and outgroup trust. IOGS and outgroup trust, in turn, predicted more positive outgroup attitudes. We ruled out alternative explanations for the results (i.e., mood, perceived positivity, and typicality of the recalled outgroup member). The findings speak to the intricate psychological processes underlying the prejudice-reduction function of nostalgia and their interventional potential. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract
Background: Automated closed loop systems may improve adaptation of the mechanical support to a patient's ventilatory needs and
facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of
ventilation.

Objectives: To compare the duration of weaning from mechanical ventilation for critically ill ventilated adults and children when managed
with automated closed loop systems versus non-automated strategies. Secondary objectives were to determine differences
in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.

Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 2); MEDLINE (OvidSP) (1948 to August 2011); EMBASE (OvidSP) (1980 to August 2011); CINAHL (EBSCOhost) (1982 to August 2011); and the Latin American and Caribbean Health Sciences Literature (LILACS). In addition we received and reviewed auto-alerts for our search strategy in MEDLINE, EMBASE, and CINAHL up to August 2012. Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles.

Selection criteria: We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning
strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an intensive care unit (ICU).

Data collection and analysis: Two authors independently extracted study data and assessed risk of bias. We combined data into forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria.

Main results: Pooled data from 15 eligible trials (14 adult, one paediatric) totalling 1173 participants (1143 adults, 30 children) indicated that automated closed loop systems reduced the geometric mean duration of weaning by 32% (95% CI 19% to 46%, P =0.002), however heterogeneity was substantial (I2 = 89%, P < 0.00001). Reduced weaning duration was found with mixed or
medical ICU populations (43%, 95% CI 8% to 65%, P = 0.02) and Smartcare/PS™ (31%, 95% CI 7% to 49%, P = 0.02) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (17%, 95% CI 8% to 26%) and ICU length of stay (LOS) (11%, 95% CI 0% to 21%). There was no difference in mortality rates or hospital LOS. Overall the quality of evidence was high with the majority of trials rated as low risk.

Authors' conclusions: Automated closed loop systems may result in reduced duration of weaning, ventilation, and ICU stay. Reductions are more
likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized
controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.