11 resultados para Measurement instruments
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Increasing emphasis is being placed on the evaluation of health-related quality of life. However, there is no consensus on the definition of this concept and as a result there are a plethora of existing measurement instruments. Head-to-head comparisons of the psychometric properties of existing instruments are necessary to facilitate evidence-based decisions about which instrument should be chosen for routine use. Therefore, an individualised instrument (the modified Patient Generated Index), a generic instrument (the Short Form 36) and a disease-specific instrument (the Quality of Life after Myocardial Infarction questionnaire) were administered to patients with ischaemic heart disease (n=117) and the evidence for the validity, reliability and sensitivity of each instrument was examined and compared. The modified Patient Generated Index compared favourably with the other instruments but none of the instruments examined provided sound evidence for sensitivity to change. Therefore, any recommendation for the use of the individualised approach in the routine collection of health-related quality of life data in clinical practice must be conditional upon the submission of further evidence to support the sensitivity of such instruments.
Resumo:
Purpose: A systematic review of the validity, reliability and sensitivity of the Short Form (SF) health survey measures among breast cancer survivors.
Methods: We searched a number of databases for peer-reviewed papers. The methodological quality of the papers was assessed using the COnsenus-based Standards for the selection of health Measurement INstruments (COSMIN).
Results: The review identified seven papers that assessed the psychometric properties of the SF-36 (n = 5), partial SF-36 (n = 1) and SF-12 (n = 1) among breast cancer survivors. Internal consistency scores for the SF measures ranged from acceptable to good across a range of language and ethnic sub-groups. The SF-36 demonstrated good convergent validity with respective subscales of the Functional Assessment of Cancer Treatment—General scale and two lymphedema-specific measures. Divergent validity between the SF-36 and Lymph-ICF was modest. The SF-36 demonstrated good factor structure in the total breast cancer survivor study samples. However, the factor structure appeared to differ between specific language and ethnic sub-groups. The SF-36 discriminated between survivors who reported or did not report symptoms on the Breast Cancer Prevention Trial Symptom Checklist and SF-36 physical sub-scales, but not mental sub-scales, discriminated between survivors with or without lymphedema. Methodological quality scores varied between and within papers.
Conclusion: Short Form measures appear to provide a reliable and valid indication of general health status among breast cancer survivors though the limited data suggests that particular caution is required when interpreting scores provided by non-English language groups. Further research is required to test the sensitivity or responsiveness of the measure.
Resumo:
Purpose of review: Appropriate selection and definition of outcome measures are essential for clinical trials to be maximally informative. Core outcome sets (an agreed, standardized collection of outcomes measured and reported in all trials for a specific clinical area) were developed due to established inconsistencies in trial outcome selection. This review discusses the rationale for, and methods of, core outcome set development, as well as current initiatives in critical care.
Recent findings: Recent systematic reviews of reported outcomes and measurement instruments relevant to the critically ill highlight inconsistencies in outcome selection, definition, and measurement, thus establishing the need for core outcome sets. Current critical care initiatives include development of core outcome sets for trials aimed at reducing mechanical ventilation duration; rehabilitation following critical illness; long-term outcomes in acute respiratory failure; and epidemic and pandemic studies of severe acute respiratory infection.
Summary: Development and utilization of core outcome sets for studies relevant to the critically ill is in its infancy compared to other specialties. Notwithstanding, core outcome set development frameworks and guidelines are available, several sets are in various stages of development, and there is strong support from international investigator-led collaborations including the International Forum for Acute Care Trialists.
Resumo:
BACKGROUND: The needs of children with autism spectrum disorder (ASD) are complex and this is reflected in the number and diversity of outcomes assessed and measurement tools used to collect evidence about children's progress. Relevant outcomes include improvement in core ASD impairments, such as communication, social awareness, sensory sensitivities and repetitiveness; skills such as social functioning and play; participation outcomes such as social inclusion; and parent and family impact.
OBJECTIVES: To examine the measurement properties of tools used to measure progress and outcomes in children with ASD up to the age of 6 years. To identify outcome areas regarded as important by people with ASD and parents.
METHODS: The MeASURe (Measurement in Autism Spectrum disorder Under Review) research collaboration included ASD experts and review methodologists. We undertook systematic review of tools used in ASD early intervention and observational studies from 1992 to 2013; systematic review, using the COSMIN checklist (Consensus-based Standards for the selection of health Measurement Instruments) of papers addressing the measurement properties of identified tools in children with ASD; and synthesis of evidence and gaps. The review design and process was informed throughout by consultation with stakeholders including parents, young people with ASD, clinicians and researchers.
RESULTS: The conceptual framework developed for the review was drawn from the International Classification of Functioning, Disability and Health, including the domains 'Impairments', 'Activity Level Indicators', 'Participation', and 'Family Measures'. In review 1, 10,154 papers were sifted - 3091 by full text - and data extracted from 184; in total, 131 tools were identified, excluding observational coding, study-specific measures and those not in English. In review 2, 2665 papers were sifted and data concerning measurement properties of 57 (43%) tools were extracted from 128 papers. Evidence for the measurement properties of the reviewed tools was combined with information about their accessibility and presentation. Twelve tools were identified as having the strongest supporting evidence, the majority measuring autism characteristics and problem behaviour. The patchy evidence and limited scope of outcomes measured mean these tools do not constitute a 'recommended battery' for use. In particular, there is little evidence that the identified tools would be good at detecting change in intervention studies. The obvious gaps in available outcome measurement include well-being and participation outcomes for children, and family quality-of-life outcomes, domains particularly valued by our informants (young people with ASD and parents).
CONCLUSIONS: This is the first systematic review of the quality and appropriateness of tools designed to monitor progress and outcomes of young children with ASD. Although it was not possible to recommend fully robust tools at this stage, the review consolidates what is known about the field and will act as a benchmark for future developments. With input from parents and other stakeholders, recommendations are made about priority targets for research.
FUTURE WORK: Priorities include development of a tool to measure child quality of life in ASD, and validation of a potential primary outcome tool for trials of early social communication intervention.
STUDY REGISTRATION: This study is registered as PROSPERO CRD42012002223.
FUNDING: The National Institute for Health Research Health Technology Assessment programme.
Resumo:
We have measured electron impact ionization cross-sections of hydrogen-like iron and hydrogen-like molybdenum with an electron beam ion trap. The measurements were performed in the electron energy range between 13.5 and 40 keV for hydrogen-like iron and between 50 and 80 keV for hydrogen-like molybdenum. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Many different immunochemical platforms exist for the screening of naturally occurring contaminants in food from the low cost enzyme linked immunosorbent assays (ELISA) to the expensive instruments such as optical biosensors based on the phenomenon of surface plasmon resonance (SPR). The primary aim of this study was to evaluate and compare a number of these platforms to assess their accuracy and precision when applied to naturally contaminated samples containing HT-2/T-2 mycotoxins. Other important factors considered were the speed of analysis, ease of use (sample preparation techniques and use of the equipment) and ultimately the cost implications. The three screening procedures compared included an SPR biosensor assay, a commercially available ELISA and an enzyme-linked immunomagnetic electrochemical array (ELIME array). The qualitative data for all methods demonstrated very good overall agreements with each other, however on comparison with mass spectrometry confirmatory results, the ELISA and SPR assay performed slightly better than the ELIME array, exhibiting an overall agreement of 95.8% compared to 91.7%. Currently, SPR is more costly than the other two platforms and can only be used in the laboratory whereas in theory both the ELISA and ELIME array are portable and can be used in the field, but ultimately this is dependent on the sample preparation techniques employed. Sample preparative techniques varied for all methods evaluated, the ELISA was the most simple to perform followed by that of the SPR method. The ELIME array involved an additional clean-up step thereby increasing both the time and cost of analysis. Therefore in the current format, field use would not be an option for the ELIME array. In relation to speed of analysis, the ELISA outperformed the other methods.
Resumo:
Capillary-based systems for measuring the input impedance of musical wind instruments were first developed in the mid-20th century and remain in widespread use today. In this paper, the basic principles and assumptions underpinning the design of such systems are examined. Inexpensive modifications to a capillary-based impedance measurement set-up made possible due to advances in computing and data acquisition technology are discussed. The modified set-up is able to measure both impedance magnitude and impedance phase even though it only contains one microphone. In addition, a method of calibration is described that results in a significant improvement in accuracy when measuring high impedance objects on the modified capillary-based system. The method involves carrying out calibration measurements on two different objects whose impedances are well-known theoretically. The benefits of performing two calibration measurements (as opposed to the one calibration measurement that has been traditionally used) are demonstrated experimentally through input impedance measurements on two test objects and a Boosey and Hawkes oboe. © S. Hirzel Verlag · EAA.
Resumo:
Data obtained with any research tool must be reproducible, a concept referred to as reliability. Three techniques are often used to evaluate reliability of tools using continuous data in aging research: intraclass correlation coefficients (ICC), Pearson correlations, and paired t tests. These are often construed as equivalent when applied to reliability. This is not correct, and may lead researchers to select instruments based on statistics that may not reflect actual reliability. The purpose of this paper is to compare the reliability estimates produced by these three techniques and determine the preferable technique. A hypothetical dataset was produced to evaluate the reliability estimates obtained with ICC, Pearson correlations, and paired t tests in three different situations. For each situation two sets of 20 observations were created to simulate an intrarater or inter-rater paradigm, based on 20 participants with two observations per participant. Situations were designed to demonstrate good agreement, systematic bias, or substantial random measurement error. In the situation demonstrating good agreement, all three techniques supported the conclusion that the data were reliable. In the situation demonstrating systematic bias, the ICC and t test suggested the data were not reliable, whereas the Pearson correlation suggested high reliability despite the systematic discrepancy. In the situation representing substantial random measurement error where low reliability was expected, the ICC and Pearson coefficient accurately illustrated this. The t test suggested the data were reliable. The ICC is the preferred technique to measure reliability. Although there are some limitations associated with the use of this technique, they can be overcome.
Resumo:
This paper presents a current and turbulence measurement campaign conducted at a test site in an energetic tidal channel known as Strangford Narrows, Northern Ireland. The data was collected as part of the MaRINET project funded by the EU under their FP7 framework. It was a collaborative effort between Queen’s University Belfast, SCHOTTEL and Fraunhofer IWES. The site is highly turbulent with a strong shear flow. Longer term measurements of the flow regime were made using a bottom mounted Acoustic Doppler Profiler (ADP). During a specific turbulence measurement campaign, two collocated in- struments were used to measure incoming flow characteristics: an ADP (Aquadopp, Nortek) and a turbulence profiler (MicroRider, Rockland Scientific International). The instruments recorded the same incoming flow, so that direct comparisons between the data can be made. In this study the methodology adopted to deploy the instruments is presented. The resulting turbulence measurements using the different types of instrumentation are compared and the usefulness of each instrument for the relevant range of applications is discussed. The paper shows the ranges of the frequency spectra obtained using the different instruments, with the combined measurements providing insight into the structure of the turbulence across a wide range of scales.
Resumo:
PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.