19 resultados para MRT,voxel-dosimetry,terapia radiometabolica

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schizophrenia (SCZ) and bipolar disorder (BP) are associated with neuropathological brain changes, which are believed to disrupt connectivity between brain processes and may have common properties. Patients at first psychotic episode are unique, as one can assess brain alterations at illness inception, when many confounders are reduced or absent. SCZ (N=25) and BP (N=24) patients were recruited in a regional first episode psychosis MRI study. VBM methods were used to study gray matter (GM) and white matter (WM) differences between patient groups and case by case matched controls. For both groups, deficits identified are more discrete than those typically reported in later stages of illness. SCZ patients showed some evidence of GM loss in cortical areas but most notable were in limbic structures such as hippocampus, thalamus and striatum and cerebellum. Consistent with disturbed neural connectivity WM alterations were also observed in limbic structures, the corpus callosum and many subgyral and sublobar regions in the parietal, temporal and frontal lobes. BP patients displayed less evidence of volume changes overall, compared to normal healthy participants, but those changes observed were primarily in WM areas which overlapped with regions identified in SCZ, including thalamus and cerebellum and subgyral and sublobar sites. At first episode of psychosis there is evidence of a neuroanatomical overlap between SCZ and BP with respect to brain structural changes, consistent with disturbed neural connectivity. There are also important differences however in that SCZ displays more extensive structural alteration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser-driven proton and ion acceleration is an area of increasing research interest given the recent development of short pulse-high intensity lasers. Several groups have reported experiments to understand whether a laser-driven beam can be applied for radiobiological purposes and in each of these, the method to obtain dose and spectral analysis was slightly different. The difficulty with these studies is that the very large instantaneous dose rate is a challenge for commonly used dosimetry techniques, so that other more sophisticated procedures need to be explored. This paper aims to explain a method for obtaining the energetic spectrum and the dose of a laser-driven proton beam irradiating a cell dish used for radiobiology studies. The procedure includes the use of a magnet to have charge and energy separation of the laser-driven beam, Gafchromic films to have information on dose and partially on energy, and a Monte Carlo code to expand the measured data in order to obtain specific details of the proton spectrum on the cells. Two specific correction factors have to be calculated: one to take into account the variation of the dose response of the films as a function of the proton energy and the other to obtain the dose to the cell layer starting from the dose measured on the films. This method, particularly suited to irradiation delivered in a single laser shot, can be applied in any other radiobiological experiment performed with laser-driven proton beams, with the only condition that the initial proton spectrum has to be at least roughly known. The method was tested in an experiment conducted at Queen's University of Belfast using the TARANIS laser, where the mean energy of the protons crossing the cells was between 0.9 and 5 MeV, the instantaneous dose rate was estimated to be close to 10(9) Gy s(-1) and doses between 0.8 and 5 Gy were delivered to the cells in a single laser shot. The combination of the applied corrections modified the initial estimate of dose by up to 40%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach to spectroscopy of laser induced proton beams using radiochromic film (RCF) is presented. This approach allows primary standards of absorbed dose-to-water as used in radiotherapy to be transferred to the calibration of GafChromic HD-810 and EBT in a 29 MeV proton beam from the Birmingham cyclotron. These films were then irradiated in a common stack configuration using the TARANIS Nd:Glass multi-terawatt laser at Queens University Belfast, which can accelerate protons to 10-12 MeV, and a depth-dose curve was measured from a collimated beam. Previous work characterizing the relative effectiveness (RE) of GafChromic film as a function of energy was implemented into Monte Carlo depth-dose curves using FLUKA. A Bragg peak (BP) "library" for proton energies 0-15 MeV was generated, both with and without the RE function. These depth-response curves were iteratively summed in a FORTRAN routine to solve for the measured RCF depth-dose using a simple direct search algorithm. By comparing resultant spectra with both BP libraries, it was found that the effect of including the RE function accounted for an increase in the total number of protons by about 50%. To account for the energy loss due to a 20 mu m aluminum filter in front of the film stack, FLUKA was used to create a matrix containing the energy loss transformations for each individual energy bin. Multiplication by the pseudo-inverse of this matrix resulted in "up-shifting" protons to higher energies. Applying this correction to two laser shots gave further increases in the total number of protons, N of 31% and 56%. Failure to consider the relative response of RCF to lower proton energies and neglecting energy losses in a stack filter foil can potentially lead to significant underestimates of the total number of protons in RCF spectroscopy of the low energy protons produced by laser ablation of thin targets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Standardized response criteria to interpret and compare clinical trials are needed for approval of new therapeutic agents by regulatory agencies. The European LeukemiaNet (ELN) response criteria for essential thrombocythemia (ET) and polycythemia vera (PV) issued in 2009 have been widely adopted as end points in a number of recent clinical trials. However, evidence exists that they do not predict response or provide clinically relevant measures of benefit for the patients. This article presents revised recommendations for assessing response in ET and PV provided by a working group established by ELN and International Working Group-Myeloproliferative Neoplasms Research and Treatment. New definitions of complete and partial remission incorporate clinical, hematological, and histological response assessments that include a standardized symptom assessment form and consider absence of disease progression and vascular events. We anticipate that these criteria will be adopted widely to facilitate the development of new and more effective therapies for ET and PV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar water disinfection (SODIS) is a well-established inexpensive means of water disinfection in developing countries, but lacks an indicator to illustrate its end-point. A study of the solar UV dosage required for SODIS, in order to achieve a bacteria concentration below the detection limit for: Escherichia coli, Enterococcus spp. and Clostridium perfringens, in water in PET bottles, PE and PE/EVA bags showed disinfection to be most efficient in PE bags, with a solar UV (290–385 nm) dose of 389 kJ m−2 required. In parallel to the disinfection experiments, a range of polyoxometalate, semiconductor photocatalysis and photodegradable dye-based solar UV dosimeter indicators were tested under the same solar UV irradiation conditions. All three types of dosimeter produced indicators that largely and significantly change colour upon exposure to 389 kJ m−2 solar UV; further indicators are reported which change colour at higher doses and hence would be suitable for the less efficient SODIS containers tested. All indicators tested were robust, easy to use and inexpensive so as not to add significantly to the attractive low cost of SODIS. Furthermore, whilst semiconductor photocatalyst and photodegradable dye based indicators are disposable, one-use systems, the polyoxometalate based indicators recover colour in the dark overnight, allowing them to be reused, and hence further decreasing the cost of using indicators during the implementation of the SODIS method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discovery of somatic mutations, primarily JAK2V617F and CALR, in classic BCR-ABL1-negative myeloproliferative neoplasms (MPNs) has generated interest in the development of molecularly targeted therapies, whose accurate assessment requires a standardized framework. A working group, comprised of members from European LeukemiaNet (ELN) and International Working Group for MPN Research and Treatment (IWG-MRT), prepared consensus-based recommendations regarding trial design, patient selection and definition of relevant end points. Accordingly, a response able to capture the long-term effect of the drug should be selected as the end point of phase II trials aimed at developing new drugs for MPNs. A time-to-event, such as overall survival, or progression-free survival or both, as co-primary end points, should measure efficacy in phase III studies. New drugs should be tested for preventing disease progression in myelofibrosis patients with early disease in randomized studies, and a time to event, such as progression-free or event-free survival should be the primary end point. Phase III trials aimed at preventing vascular events in polycythemia vera and essential thrombocythemia should be based on a selection of the target population based on new prognostic factors, including JAK2 mutation. In conclusion, we recommended a format for clinical trials in MPNs that facilitates communication between academic investigators, regulatory agencies and drug companies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To demonstrate the benefit of complexity metrics such as the modulation complexity score (MCS) and monitor units (MUs) in multi-institutional audits of volumetric-modulated arc therapy (VMAT) delivery.

METHODS: 39 VMAT treatment plans were analysed using MCS and MU. A virtual phantom planning exercise was planned and independently measured using the PTW Octavius(®) phantom and seven29(®) 2D array (PTW-Freiburg GmbH, Freiburg, Germany). MCS and MU were compared with the median gamma index pass rates (2%/2 and 3%/3 mm) and plan quality. The treatment planning systems (TPS) were grouped by VMAT modelling being specifically designed for the linear accelerator manufacturer's own treatment delivery system (Type 1) or independent of vendor for VMAT delivery (Type 2). Differences in plan complexity (MCS and MU) between TPS types were compared.

RESULTS: For Varian(®) linear accelerators (Varian(®) Medical Systems, Inc., Palo Alto, CA), MCS and MU were significantly correlated with gamma pass rates. Type 2 TPS created poorer quality, more complex plans with significantly higher MUs and MCS than Type 1 TPS. Plan quality was significantly correlated with MU for Type 2 plans. A statistically significant correlation was observed between MU and MCS for all plans (R = -0.84, p < 0.01).

CONCLUSION: MU and MCS have a role in assessing plan complexity in audits along with plan quality metrics. Plan complexity metrics give some indication of plan deliverability but should be analysed with plan quality.

ADVANCES IN KNOWLEDGE: Complexity metrics were investigated for a national rotational audit involving 34 institutions and they showed value. The metrics found that more complex plans were created for planning systems which were independent of vendor for VMAT delivery.