45 resultados para Laser scanning

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper compares the applicability of three ground survey methods for modelling terrain: one man electronic tachymetry (TPS), real time kinematic GPS (GPS), and terrestrial laser scanning (TLS). Vertical accuracy of digital terrain models (DTMs) derived from GPS, TLS and airborne laser scanning (ALS) data is assessed. Point elevations acquired by the four methods represent two sections of a mountainous area in Cumbria, England. They were chosen so that the presence of non-terrain features is constrained to the smallest amount. The vertical accuracy of the DTMs was addressed by subtracting each DTM from TPS point elevations. The error was assessed using exploratory measures including statistics, histograms, and normal probability plots. The results showed that the internal measurement accuracy of TPS, GPS, and TLS was below a centimetre. TPS and GPS can be considered equally applicable alternatives for sampling the terrain in areas accessible on foot. The highest DTM vertical accuracy was achieved with GPS data, both on sloped terrain (RMSE 0.16. m) and flat terrain (RMSE 0.02. m). TLS surveying was the most efficient overall but veracity of terrain representation was subject to dense vegetation cover. Therefore, the DTM accuracy was the lowest for the sloped area with dense bracken (RMSE 0.52. m) although it was the second highest on the flat unobscured terrain (RMSE 0.07. m). ALS data represented the sloped terrain more realistically (RMSE 0.23. m) than the TLS. However, due to a systematic bias identified on the flat terrain the DTM accuracy was the lowest (RMSE 0.29. m) which was above the level stated by the data provider. Error distribution models were more closely approximated by normal distribution defined using median and normalized median absolute deviation which supports the use of the robust measures in DEM error modelling and its propagation. © 2012 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Laboratory salt decay simulations are a well established method to assess the relative durability of stone. There is still, however, very much scope to implement improved monitoring techniques to investigate the changes experienced by the materials during these experiments. Non-destructive techniques have acquired over recent decades a preferential status for monitoring change samples during salt decay tests, as they allow cumulative tests on each sample. The development of HD laser scanning permits detailed mapping of surface changes and, therefore, constitutes an effective technique to monitor non-destructively surface changes in tested samples as an alternative to other monitoring techniques such as traditional weight loss strategies that do not permit any degree of spatial differentiation that can be related, for example, to underlying stone properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The training of Irish soldiers for service in the British Army during the First World War required the establishment of training camps across the island, such as at Shane’s Castle Estate, close to Randalstown in County Antrim, Northern Ireland. The camp saw active use from 1914 to 1918 but after the war it was demilitarised and returned to use as farmland. Archaeological investigations have revealed that earthwork traces of the camp can still be identified in the modern landscape. Comparison of a map of the camp from 1915, Airborne Laser Scanning data and aerial photographs has enabled the footprint of the camp to be re-established, while also helping to identify the location of specific elements such as the remains of barrack huts, stores, mess halls and officers’ quarters.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this investigation we describe the preparation, physical characterisation and in vivo behaviour of solid dispersions of a liquid nutraceutical, ±-tocopherol, in Gelucire 44/14 with a view to establishing whether dispersion in this matrix may provide a means of formulating a liquid drug in a solid dosage form while also improving the oral bioavailability. Using Vitamin E Preparation USP as the source of ±-tocopherol, dispersions were prepared using a melt-fusion method with active loadings up to 50% (w/w) and characterised using differential scanning calorimetry and optical microscopy. Capsules containing 300 IU ±-tocopherol were manufactured and the absorption profiles compared to a commercial soft gelatin capsule preparation in healthy human volunteers. Confocal laser scanning microscopy (CLSM) studies were performed in order to elucidate the mechanism by which drug release may be occurring. Differential scanning calorimetry studies indicated that the presence of the active had a negligible effect on the melting profile of the carrier, indicating limited miscibility between the two components, a conclusion supported by the microscopy studies. Similarly, the dispersions were shown to exhibit a glass transition corresponding to the incorporated drug, indicating molecular cooperativity and hence phase separation from the lipid base. Despite the phase separation, it was noted that capsules stored for 18 months under ambient conditions showed no evidence of leakage. Bioavailability studies in six healthy male volunteers indicated that the Gelucire 44/14 formulation showed an approximately two-fold increase in total ±-tocopherol absorption compared to the commercial preparation. Confocal laser scanning microscopy studies indicated that, on contact with water, the dispersions formed two interfacial layers, from which the Gelucire 44/14 disperses in the liquid medium as small particles. Furthermore, evidence was obtained for the dispersed material becoming incorporated into the hydrated lipid. In conclusion, the dispersion of the liquid drug in Gelucire 44/14 appears to allow the dual advantages of the preparation of a solid formulation and improved bioavailability of this material.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The synthesis, complexation, and photophysical properties of the Eu(III)-based quinoline cyclen conjugate complex Eu1 and its permanent, noncovalent incorporation into hydrogels as sensitive, interference-free pH sensing materials for biological media are described. The Eu(III) emission in both solution and hydrogel media was switched reversibly on-off as a function of pH with a large, greater than order of magnitude enhancement in Eu(III) emission. The irreversible incorporation of Eu1 into water-permeable hydrogels was achieved using poly[methyl methacrylate-co-2-hydroxyethyl methacrylate]- based hydrogels, and the luminescent properties of the novel sensor materials, using confocal laser- scanning microscopy and steady state luminescence, were characterized and demonstrated to be retained with respect to solution behavior. Water uptake and dehydration behavior of the sensor-incorporated materials was also characterized and shown to be dependent on the material composition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Blood-brain barrier (BBB) breakdown, demonstrable in vivo by enhanced MRI is characteristic of new and expanding inflammatory lesions in relapsing remitting and chronic progressive multiple sclerosis (MS). Subtle leakage may also occur in primary progressive MS. However, the anatomical route(s) of BBB leakage have not been demonstrated. We investigated the possible involvement of interendothelial tight junctions (TJ) by examining the expression of TJ proteins (occludin and ZO-1 ) in blood vessels in active MS lesions from 8 cases of MS and in normal-appearing white (NAWM) matter from 6 cases. Blood vessels (10-50 per frozen section) were scanned using confocal laser scanning microscopy to acquire datasets for analysis. TJ abnormalities manifested as beading, interruption, absence or diffuse cytoplasmic localization of fluorescence, or separation of junctions (putative opening) were frequent (affecting 40% of vessels) in oil red-O-positive active plaques but less frequent in NAWM (15%), and in normal (

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: We describe the presence of interstitial cells of Cajal (ICC) throughout the wall of the guinea pig bladder. MATERIALS AND METHODS: Bladders obtained from male guinea pigs were prepared for immunohistochemical investigations using various primary antibodies, including the specific ICC marker c-kit (Gibco BRL, Grand Island, New York). Enzymatically dispersed cells with a branched morphology were identified as ICC using anti-c-kit. They were loaded with fluo-4acetoxymethyl (Molecular Probes, Eugene, Oregon) and studied using confocal laser scanning microscopy. RESULTS: Anti-c-kit labeling demonstrated that ICC were oriented in parallel with the smooth muscle bundles that run diagonally throughout the bladder. Double labeling with anti-smooth muscle myosin (Sigma Chemical Co., St. Louis, Missouri) revealed that ICC were located on the boundary of smooth muscle bundles. When anti-c-kit was used in combination with the general neuronal antibody protein gene product 9.5 (Ultraclone Ltd., Isle of Wight, United Kingdom) or anti-neuronal nitric oxide synthase, it was noted that there was a close association between nerves and ICC. Enzymatic dissociation of cells from tissue pieces yielded a heterogeneous population of cells containing typical spindle-shaped smooth muscle cells and branched cells resembling ICC from other preparations. The latter could be identified immunohistochemically as ICC using anti-c-kit, whereas the majority of spindle-shaped cells were not Kit positive. Branched cells responded to the application of carbachol by firing Ca2+ waves and they were often spontaneously active. CONCLUSIONS: ICC are located on the boundary of smooth muscle bundles in the guinea pig bladder. They fire Ca2+ waves in response to cholinergic stimulation and can be spontaneously active, suggesting that they could act as pacemakers or intermediaries in the transmission of nerve signals to smooth muscle cells.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The synthesis and photophysical evaluation of a new supramolecular lanthanide complex is described which was developed as a luminescent contrast agent for bone structure analysis. We show that the Eu(III) emission of this complex is not pH dependent within the physiological pH range, and that its steady state emission is not significantly modulated by a series of group I and II as well as d-metal ions, and that this agent can be successfully employed to image mechanically formed cracks (scratches) in bone samples after 4 or 24 hours, using confocal laser-scanning microscopy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: The authors estimated the retinal nerve fiber layer height (RNFLH) measurements in patients with glaucoma compared with those in age-matched healthy subjects as obtained by the laser scanning tomography and assessed the relationship between RNFLH measurements and optic and visual field status. Methods: Parameters of optic nerve head topography and RNFLH were evaluated in 125 eyes of 21 healthy subjects and 104 patients with glaucoma using the Heidelberg Retina Tomograph ([HRT] Heidelberg Engineering GmbH, Heidelberg, Germany) for the entire disc area and for the superior 70°(50°temporal and 20°nasal to the vertical midline) and inferior 70°sectors of the optic disc. The mean deviation of the visual field, as determined by the Humphrey program 24-2 (Humphrey Instruments, Inc., San Leonardo, CA, U.S.A) was calculated in the entire field and in the superior and inferior Bjerrum area. Result: Retinal nerve fiber layer height parameters (mean RNFLH and RNFL cross-sectional area) were decreased significantly in patients with glaucoma compared with healthy individuals. Retinal nerve fiber layer height parameters was correlated strongly with rim volume, rim area, and cup/disc area ratio. Of the various topography measures, retinal nerve fiber layer (RNFL) parameters and cup/disc area ratio showed the strongest correlation with visual field mean deviation in patients with glaucoma. Conclusion: Retinal nerve fiber layer height measures were reduced substantially in patients with glaucoma compared with age-matched healthy subjects. Retinal nerve fiber layer height was correlated strongly with topographic optic disc parameters and visual field changes in patients with glaucoma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although the antimicrobial activity of atmospheric pressure non-thermal plasmas, including its capacity to eradicate microbial biofilms, has been gaining an ever increasing interest for different medical applications, its potential utilisation in the control of biofouling and biodeterioration has, to date, received no attention. In this study, the ability of atmospheric pressure plasma to eradicate biofilms of four biofouling bacterial species, frequently encountered in marine environments, was investigated. Biofilms were grown on both polystyrene and stainless steel surfaces before being exposed to the plasma source. Viability and biomass of biofilms were evaluated using colony count method and differential Live/Dead fluorescence staining followed by confocal laser scanning microscopy. Rapid and complete eradication of all biofilms under study was achieved after plasma exposures ranging from 60 to 120 s. Confocal microscopy examination showed that plasma treatment has mediated not only cell killing but also varying degrees of physical removal of biofilms. Further investigation and tailored development of atmospheric pressure non-thermal plasma sources for this particular application could provide an additional powerful and effective weapon in the current anti-biofouling armamentarium.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A systematic study was undertaken to gain more insight into the mechanism of transdermal delivery of nanoencapsulated model dyes across microneedle (MN)-treated skin, a complex process not yet explored. Rhodamine B (Rh B) and fluorescein isothiocyanate (FITC) as model hydrophilic and hydrophobic small/medium-size molecules, respectively, were encapsulated in poly lactic-co-glycolic acid (PLGA) nanoparticles (NPs) and delivered through full thickness porcine skin pretreated with MN array. Permeation through MN-treated skin was affected by physicochemical characteristics of NPs and the encapsulated dyes. Dye flux was enhanced by smaller particle size, hydrophilicity, and negative zeta potential of NPs. Regarding encapsulated dyes, solubility at physiological pH and potential interaction with skin proteins proved to outweigh molecular weight as determinants of skin permeation. Data were verified using confocal laser scanning microscopy imaging. Findings coupled with the literature data are supportive of a mechanism involving influx of NPs, particularly of smaller size, deep into MN-created channels, generating depot dye-rich reservoirs. Molecular diffusion of the released dye across viable skin layers proceeds at a rate determined by its molecular characteristics. Data obtained provide mechanistic information of importance to the development of formulation strategies for more effective intradermal and transdermal MN-mediated delivery of nanoencapsulated therapeutic agents.