18 resultados para Laser diode (LD) pumping

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report on a time-resolved study of a Ni-like transient collisionnal X-ray laser with a resolution as high as 1.9 ps The FWHM duration of the Ni-like x-ray laser pulse at 13.99 nin Ag J = 0 -->1 4d-4p line is measured to be as short as similar to2 ps at optimum conditions of pump laser irradiation. This is about four times shorter than was estimated in previous experiments. The x-ray laser signal appears in the rising edge of the continuum emission. The x-ray laser duration rises significantly when the short (heating) pulse duration is increased and when doubling the peak-to-peak delay of the two irradiation pulses, It does not change when the short pulse energy is increased. The results presented are the first direct measurements of the temporal profile of the x-ray laser output at a high resolution.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Saturated output has been observed for both Ne and Ni-like X-ray lasers when Pumped in the transient mode. As these 'normal' transitions display very high gain, attempts have been made to observe a 2p --> 2s inner shell transition in Ne-like ions, which scale well towards the water window. Modelling of the pump conditions for Ge lasing at 6.2 run is presented. As the predicted gain is low the experiment was set up for 18 mm targets. Shots were taken on Ti, Fe, Ni and Ge. A similar to1.5 ps travelling wave pulse is applied at various times after the peak of a long, preforming Pulse. Various pump conditions were attempted but no inner shell X-ray laser was detected.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report what is to our knowledge the first demonstration of a transient x-ray laser pumped by a 350-fs pulse in a traveling-wave irradiation geometry. For a 500-fs pump pulse the traveling-wave irradiation was found to have a strong effect on enhancing the Ni-like silver 4d-4p lasing emission at 13.9 nm. The signal enhancement was significantly less when the pulse duration was lengthened to 1.7 ps. The experimental observations are well reproduced by a simple model when the duration of gain is taken of the order of 15-20 ps. For the 500-fs pulse a gain coefficient of 14.5 cm(-1) was measured for plasma lengths up to 7 mm. Refraction of the amplified photons is believed to be the main cause of the limitation of the effective amplification length. (C) 2000 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To report a case of malignant glaucoma after diode laser cyclophotocoagulation. METHOD: Case report. RESULTS: A 45-year-old man with uncontrolled secondary glaucoma in his right eye after corneoscleral graft and cataract extraction underwent diode laser cyclophotocoagulation. The right eye was aphakic, with an intact posterior capsule. Two weeks later, the patient presented with blurred vision, edematous cornea, and flat anterior chamber. The posterior capsule was touching the endothelium. Intraocular pressure was 20 mm Hg. Repeated Nd:YAG laser capsulotomy was effective in reversing the malignant glaucoma attack, and the anterior chamber deepened. CONCLUSION: Malignant glaucoma can occur after diode laser cyclophotocoagulation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We evaluated the effectiveness of diode laser trans-scleral cyclophotocoagulation (TSCPC) on intraocular pressure (IOP) in nine patients having raised IOP following use of silicone oil (SO) for retinal detachment (RD) surgery in a retrospective observational case series. Diode laser TSCPC was applied at a power setting of 1.75 to 2.5 watts, for two sec with a maximum of 30 applications. The patients were followed up for 40 to 312 weeks. The mean pre-laser IOP was 32.06 mm Hg (SD 7.32). The mean post-laser IOP at one month, three months and six months was 17.89 mm Hg (SD 8.23), 21.89 mm Hg (SD 8.16) and 21.67 mm Hg (SD 7.55) respectively. The final IOP (at the last follow-up) was 19.56 mm Hg (SD 7.85) (P=0.021). Seven of them had undergone SO removal. In our observation, effectiveness of TSCPC in long-term control of SO-induced ocular hypertension was limited as compared to short-term control of IOP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent experiments undertaken at the Rutherford Appleton Laboratory to produce X-ray lasing over the 5-30 nm wavelength range are reviewed. The efficiency of lasing is optimized when the main pumping pulse interacts with a preformed plasma. Experiments using double 75-ps pulses and picosecond pulses superimposed on 300-ps background pulses are described. The use of travelling wave pumping with the approximately picosecond pulse experiments is necessary as the gain duration becomes comparable to the time for the X-ray laser pulse to propagate along the target length. Results from a model taking account of laser saturation and deviations from the speed of light c of the travelling wave and X-ray laser group velocity are presented. We show that X-ray laser pulses as short as 2-3 ps can be produced with optical pumping pulses of approximate to1-ps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper summarises die main results obtained during the two experimental campaigns on TCE X-ray lasers that we have carried out since the last Kyoto X-ray laser Conference in 1998. A two-color (2 omega /1 omega) pumping configuration was tested and led to the observation of a strong lasing line at 16 nm, identified to a 4f-4d transition in Ni-like Ag. A strong x 300-400 enhancement of the 13.9 nm Ni-like 4d-4p lasing emission was obtained when a traveling wave short pulse pumping was applied. Finally the temporal history of the 13.9 nm laser pulse was measured with a high-resolution Streak camera, A very short 2 ps X-ray laser pulse was directly demonstrated for the first time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent progress using the VULCAN laser at the Rutherford Appleton Laboratory to pump X-ray lasing in nickel-like ions is reviewed. Double pulse pumping with similar to 100 ps pulses has been shown to produce significantly greater X-ray laser output than single pulses of duration 0.1-1 ns. With double pulse pumping, the main pumping pulse interacts with a pre-formed plasma created by a pre-pulse. The efficiency of lasing increases as there is a reduced effect of refraction of the X-ray laser beam due to smaller density gradients and larger gain volumes, which enable propagation of the X-ray laser beam along the full length of the target. The record shortest wavelength saturated laser at 5.9 nm has been achieved in Ni-like dysprosium using double pulse pumping of 75 ps duration from the VULCAN laser. A variant of the double pulse pumping using a single similar to 100 ps laser pulse and a superimposed short similar to 1 ps pulse has been found to further increase the efficiency of lasing by reducing the effects of over-ionisation during the gain period. The record shortest wavelength saturated laser pumped by a short similar to 1 ps pulse has been achieved in Ni-like samarium using the VULCAN laser operating in chirped pulse amplified (CPA) mode. Ni-like samarium lases at 7.3 nm. (C) 2000 Academie des sciences/Editions scientifiques et medicales Elsevier SAS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A similar to 3 ps travelling wave chirped pulse amplified pulse at 6 x 10(14) W cm(-2) superimposed on similar to 300 ps background pulses is shown to be an efficient method to pump transient collisional excitation X-ray lasers in both Ni-like and Ne-like ions. Measurements of X-ray laser output as a function of plasma length are fitted with results of an amplified spontaneous emission model of the laser output taking account of travelling wave pumping effects. A small signal gain coefficient similar to 42 cm(-1) and a effective gain length product of similar to 18 are measured for the Ni-like Sn laser at 120 Angstrom. Simulations from a hydrodynamic and atomic physics code (EHYBRID) coupled to a ray trace code show that a spatially averaged small signal gain similar to 65 cm(-1) can be obtained in Ne-like Ge provided the optimum pumping pulse arrangement is used. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a systematic study of double pulse pumping of the Ni-like Sm x-ray laser at 73 Angstrom, currently the shortest wavelength saturated x-ray laser. It is found that the Sm x-ray laser output can change by orders of magnitude when the intensity ratio of the pumping pulses and their relative delay are varied. Optimum pumping conditions are found and interpreted in terms of a simple model. (C) 1999 American Institute of Physics. [S0021-8979(99)07102-9].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The transient-excitation pumping scheme, in which a picosecond duration pulse rapidly heats the plasma preformed by a low-intensity nanosecond pulse, was used to pump the Ne-like germanium, J = 0-1 transition at 19.6 nm. A small-signal gain coefficient of 30 cm(-1) was measured for targets less than or equal to 5 mm long. (C) 1998 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multipulse irradiation with 100 ps pulses of stripe Germanium targets is shown to enhance by up to several orders-of-magnitude the output of Ne-like Ge lasing on the J = 0-1 line at 196 Angstrom compared to single pulse pumping. Various pre-pulse and multipulse configurations have been experimentally investigated for irradiances of approximate to 4 x 10(13) W/cm(2) with a 1.06 mu m wavelength pumping laser. The ionisation balance measured by a KeV crystal spectrometer (KAP crystal) has been found to not affect the X-ray laser output. Good agreement between the experimental results and a fluid code incorporating atomic physics, gain and X-ray beam ray tracing is obtained. The code results show that the enhanced X-ray laser output is produced by multipulse irradiation reducing the electron density gradients in the gain region and simultaneously increasing the gain region spatial size. These changes reduce the effect of refraction on the X-ray laser beam propagation.