61 resultados para Hydraulic brakes.

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the problem of seepage under the floor of hydraulic structures considering the compartment of flow that seeps through the surrounding banks of the canal. A computer program, utilizing a finite-element method and capable of handling three-dimensional (3D) saturated–unsaturated flow problems, was used. Different ratios of canal width/differential head applied on the structure were studied. The results produced from the two-dimensional (2D) analysis were observed to deviate largely from that obtained from 3D analysis of the same problem, despite the fact that the porous medium was isotropic and homogeneous. For example, the exit gradient obtained from 3D analysis was as high as 2.5 times its value obtained from 2D analysis. Uplift force acting upwards on the structure has also increased by about 46% compared with its value obtained from the 2D solution. When the canal width/ differential head ratio was 10 or higher, the 3D results were comparable to the 2D results. It is recommended to construct a core of low permeability soil in the banks of canal to reduce the seepage losses, uplift force, and exit gradient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research investigated seepage under hydraulic structures considering flow through the banks of the canal. A computer model, utilizing the finite element method, was used. Different configurations of sheetpile driven under the floor of the structure were studied. Results showed that the transverse extension of sheetpile, driven at the middle of the floor, into the banks of the canal had very little effect on seepage losses, uplift force, and on the exit gradient at the downstream end of the floor. Likewise, confining the downstream floor with sheetpile from three sides was not found effective. When the downstream floor was confined with sheetpile from all sides, this has significantly reduced the exit gradient. Furthermore, all the different configurations of the sheetpile had insignificant effect on seepage losses. The most effective configuration of the sheetpile was the case when two rows of sheetpiles were driven at the middle and at the downstream end of the floor, with the latter sheetpile extended few meters into the banks of the canal. This case has significantly reduced the exit gradient and caused only slight increase in the uplift force when compared to other sheetpile configurations. The present study suggests that two-dimensional analysis of seepage problems underestimates the exit gradient and uplift force on hydraulic structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regional groundwater flow in high mountainous terrain is governed by a multitude of factors such as geology, topography, recharge conditions, structural elements such as fracturation and regional fault zones as well as man-made underground structures. By means of a numerical groundwater flow model, we consider the impact of deep underground tunnels and of an idealized major fault zone on the groundwater flow systems within the fractured Rotondo granite. The position of the free groundwater table as response to the above subsurface structures and, in particular, with regard to the influence of spatial distributed groundwater recharge rates is addressed. The model results show significant unsaturated zones below the mountain ridges in the study area with a thickness of up to several hundred metres. The subsurface galleries are shown to have a strong effect on the head distribution in the model domain, causing locally a reversal of natural head gradients. With respect to the position of the catchment areas to the tunnel and the corresponding type of recharge source for the tunnel inflows (i.e. glaciers or recent precipitation), as well as water table elevation, the influence of spatial distributed recharge rates is compared to uniform recharge rates. Water table elevations below the well exposed high-relief mountain ridges are observed to be more sensitive to changes in groundwater recharge rates and permeability than below ridges with less topographic relief. In the conceptual framework of the numerical simulations, the model fault zone has less influence on the groundwater table position, but more importantly acts as fast flow path for recharge from glaciated areas towards the subsurface galleries. This is in agreement with a previous study, where the imprint of glacial recharge was observed in the environmental isotope composition of groundwater sampled in the subsurface galleries. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the trajectory control of a 2DOF mini electro-hydraulic excavator by using fuzzy self tuning with neural network algorithm. First, the mathematical model is derived for the 2DOF mini electro-hydraulic excavator. The fuzzy PID and fuzzy self tuning with neural network are designed for circle trajectory following. Its two links are driven by an electric motor controlled pump system. The experimental results demonstrated that the proposed controllers have better control performance than the conventional controller.