10 resultados para Hors-bord -- Compétitions -- Monaco

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to design a treatment that would dematerialise an above ground gas installation on the Liffey quayside while still meeting the functional requirement to ventilate the pressure reducing chamber inside. To do this we wrapped the installation in a skin of glass that allows the air to enter below the skin and to escape behind the parapet. The installation building is covered in plastic sequins and the glass is treated with alternating bands of dichroic film. The flow of air causes the sequins to shimmer reflecting spots of coloured light back onto the glass. At night a similar effect is created by lighting concealed within the outer skin. This project won a commendation in the RIAI Awards 2010, and an AAI award in 2011. It was published in New Irish Architecture 26. The British architectural historian William JR Curtis described it as ‘a beautiful understated little kiosk.’

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report results on the performance of a free-electron laser operating at a wavelength of 13.7 nm where unprecedented peak and average powers for a coherent extreme-ultraviolet radiation source have been measured. In the saturation regime, the peak energy approached 170 J for individual pulses, and the average energy per pulse reached 70 J. The pulse duration was in the region of 10 fs, and peak powers of 10 GW were achieved. At a pulse repetition frequency of 700 pulses per second, the average extreme-ultraviolet power reached 20 mW. The output beam also contained a significant contribution from odd harmonics of approximately 0.6% and 0.03% for the 3rd (4.6 nm) and the 5th (2.75 nm) harmonics, respectively. At 2.75 nm the 5th harmonic of the radiation reaches deep into the water window, a wavelength range that is crucially important for the investigation of biological samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intracranial metastatic prostate carcinoma is rare. We sought to determine the clinical outcomes after Gamma Knife® stereotactic radiosurgery (GKSRS) for patients with intracranial prostate carcinoma metastases. We studied data from 10 patients who underwent radiosurgery for 15 intracranial metastases (9 dural-based and 6 parenchymal). Six patients had radiosurgery for solitary tumors and four had multiple tumors. The primary pathology was adenocarcinoma (eight patients) and small cell carcinoma (two patients). All patients received multimodality management for their primary tumor (including resection, radiation therapy, androgen deprivation therapy) and eight patients had evidence of systemic disease at time of radiosurgery. The mean tumor volume was 7.7 cm3 (range 1.1-17.2 cm3) and a median margin dose of 16 Gy was administered. Two patients had progressive intracranial disease in spite of fractionated partial brain radiation therapy (PBRT) prior to SRS. A local tumor control rate of 85% was achieved (including patients receiving boost, upfront and salvage SRS). New remote brain metastases developed in three patients (33%) and one patient had repeat SRS for tumor recurrence. The median survival after radiosurgery was 13 months and the 1-year survival rate was 60%. SRS was a well tolerated and effective therapy either alone or as a boost to fractionated radiation therapy in the management of patients with intracranial prostate carcinoma metastases. © 2009 Springer Science+Business Media, LLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine the indication and outcomes for Gamma Knife stereotactic radiosurgery (GKSRS) in the care of patients with intracranial sarcomatous metastases. Methods and Materials: Data from 21 patients who underwent radiosurgery for 60 sarcomatous intracranial metastases (54 parenchymal and 6 dural-based) were studied. Nine patients had radiosurgery for solitary tumors and 12 for multiple tumors. The primary pathology was metastatic leiomyosarcoma (4 patients), osteosarcoma (3 patients), soft-tissue sarcoma (5 patients), chondrosarcoma (2 patients), alveolar soft part sarcoma (2 patients), and rhabdomyosarcoma, Ewing's sarcoma, liposarcoma, neurofibrosarcoma, and synovial sarcoma (1 patient each). Twenty patients received multimodality management for their primary tumor, and 1 patient had no evidence of systemic disease. The mean tumor volume was 6.2 cm 3 (range, 0.07-40.9 cm 3), and a median margin dose of 16 Gy was administered. Three patients had progressive intracranial disease despite fractionated whole-brain radiotherapy before SRS. Results: A local tumor control rate of 88% was achieved (including patients receiving boost, up-front, and salvage SRS). New remote brain metastases developed in 7 patients (33%). The median survival after diagnosis of intracranial metastasis was 16 months, and the 1-year survival rate was 61%. Conclusions: Gamma Knife radiosurgery was a well-tolerated and initially effective therapy in the management of patients with sarcomatous intracranial metastases. However, many patients, including those who also received fractionated whole-brain radiotherapy, developed progressive new brain disease. © 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: We have been developing an image-guided single vocal cord irradiation technique to treat patients with stage T1a glottic carcinoma. In the present study, we compared the dose coverage to the affected vocal cord and the dose delivered to the organs at risk using conventional, intensity-modulated radiotherapy (IMRT) coplanar, and IMRT non-coplanar techniques.

METHODS AND MATERIALS: For 10 patients, conventional treatment plans using two laterally opposed wedged 6-MV photon beams were calculated in XiO (Elekta-CMS treatment planning system). An in-house IMRT/beam angle optimization algorithm was used to obtain the coplanar and non-coplanar optimized beam angles. Using these angles, the IMRT plans were generated in Monaco (IMRT treatment planning system, Elekta-CMS) with the implemented Monte Carlo dose calculation algorithm. The organs at risk included the contralateral vocal cord, arytenoids, swallowing muscles, carotid arteries, and spinal cord. The prescription dose was 66 Gy in 33 fractions.

RESULTS: For the conventional plans and coplanar and non-coplanar IMRT plans, the population-averaged mean dose ± standard deviation to the planning target volume was 67 ± 1 Gy. The contralateral vocal cord dose was reduced from 66 ± 1 Gy in the conventional plans to 39 ± 8 Gy and 36 ± 6 Gy in the coplanar and non-coplanar IMRT plans, respectively. IMRT consistently reduced the doses to the other organs at risk.

CONCLUSIONS: Single vocal cord irradiation with IMRT resulted in good target coverage and provided significant sparing of the critical structures. This has the potential to improve the quality-of-life outcomes after RT and maintain the same local control rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Case C-258/11 Peter Sweetman, Ireland, Attorney General, Minister for the Environment, Heritage and Local Government v An Bord Pleanála
(Not yet reported)