19 resultados para HPGe detector

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

MALDI (matrix-assisted laser desorption/ionization) is one of the most important techniques used to produce large biomolecular ions in the gas phase. Surprisingly, the exact ionization mechanism is still not well understood and absolute values for the ion yields are scarce. This is in part due to the unknown efficiencies of typical detectors, especially for heavy biomolecular ions. As an alternative, charged particles can be non-destructively detected using an image-charge detector where the output voltage signal is proportional to the total charge within the device. In this paper, we report an absolute calibration which provides the voltage output per detected electronic charge in our experimental arrangement. A minimum of 3 x 10(3) ions were required to distinguish the signal above background noise in a single pass through the device, which could be further reduced using filtering techniques. The calibration results have been applied to raw MALDI spectra to measure absolute ion yields of both matrix and analyte ions.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:



Email
Print
Request Permissions











A compact V-band active power detector using Infineon 0.35 µm SiGe HBT process (fT/fmax =170/250 GHz) is described. The total chip area is only 0.35×0.8 mm2 including all pads. This design exhibits a dynamic range larger than 20 dB over the frequency range from 55 GHz to 67 GHz. It also offers a simple and low-power application potential as an envelop detector in multi-Gbps high data rate demodulators for OOK/ASK etc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we propose a sparse signal modulation (SSM) method for precoded orthogonal frequency division multiplexing (OFDM) systems and study the signal detection. Although a receiver is able to exploit a path diversity gain with random precoding in OFDM, the complexity of the receiver is usually high as the orthogonality is not retained due to precoding. However, with SSM, we can derive a low-complexity detector that can provide reasonably good performances with a low sparsity ratio based on the notion of compressive sensing (CS). An important feature of a CS detector is that it can estimate SSM signals with a small fraction of the received signals over sub-carriers. This feature can allow us to build a low cost receiver with a small number of demodulators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple circuit that is able to indicate if an injection-locked oscillator is in the locked condition by providing a ‘high’ or ‘low’ output is presented. The detector is compatible with most injection-locked oscillators as all that is required is access to the low-frequency bias circuit, with no direct access needed to the RF/microwave signals. To prove the universal nature of the lock detector it is successfully demonstrated practically for two scenarios: (i) a 1 GHz injection-locked VCO and (ii) a 60 GHz SiGe VCO MMIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As cryptographic implementations are increasingly subsumed as functional blocks within larger systems on chip, it becomes more difficult to identify the power consumption signatures of cryptographic operations amongst other unrelated processing activities. In addition, at higher clock frequencies, the current decay between successive processing rounds is only partial, making it more difficult to apply existing pattern matching techniques in side-channel analysis. We show however, through the use of a phase-sensitive detector, that power traces can be pre-processed to generate a filtered output which exhibits an enhanced round pattern, enabling the identification of locations on a device where encryption operations are occurring and also assisting with the re-alignment of power traces for side-channel attacks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter analyzes the performance of a low complexity detection scheme for a multi-carrier index keying (MCIK) with orthogonal frequency division multiplexing (OFDM) system over two-wave with diffused power (TWDP) fading channels. A closed-form expression for the average pairwise error probability (PEP) over TWDP fading channels is derived. This expression is used to analyze the performance of MCIK-OFDM in moderate, severe and extreme fading conditions. The presented results provide an insight on the performance of MCIK-OFDM for wireless communication systems that operate in enclosed metallic structures such as in-vehicular device-to-device (D2D) wireless networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the PTW 1000SRS array with Octavius 4D phantom was characterised for FF and FFF beams. MU linearity, field size, dose rate, dose per pulse (DPP) response and dynamic conformal arc treatment accuracy of the 1000SRS array were assessed for 6MV, 6FFF and 10FFF beams using a Varian TrueBeam STx linac. The measurements were compared with a pinpoint IC, microdiamond IC and EBT3 Gafchromic film. Measured dose profiles and FWHMs were compared with film measurements. Verification of FFF volumetric modulated arc therapy (VMAT) clinical plans were assessed using gamma analysis with 3%/3 mm and 2%/2 mm tolerances (10% threshold). To assess the effect of cross calibration dose rate, clinical plans with different dose rates were delivered and analysed. Output factors agreed with film measurements to within 4.5% for fields between 0.5 and 1 cm and within 2.7% for field sizes between 1.5 and 10 cm and were highly correlated with the microdiamond IC detector. Field sizes measured with the 1000SRS array were within 0.5 mm of film measurements. A drop in response of up to 1.8%, 2.4% and 5.2% for 6MV, 6FFF and 10FFF beams respectively was observed with increasing nominal dose rate. With an increase in DPP, a drop of up to 1.7%, 2.4% and 4.2% was observed in 6MV, 6FFF and 10FFF respectively. The differences in dose following dynamic conformal arc deliveries were less than 1% (all energies) from calculated. Delivered VMAT plans showed an average pass percentage of 99.5(±0.8)% and 98.4(±3.4)% with 2%/2 mm criteria for 6FFF and 10FFF respectively. A drop to 97.7(±2.2)% and 88.4(±9.6)% were observed for 6FFF and 10FFF respectively when plans were delivered at the minimum dose rate and calibrated at the maximum dose rate. Calibration using a beam with the average dose rate of the plan may be an efficient method to overcome the dose rate effects observed by the 1000SRS array.