Background Person-to-person transmission of respiratory pathogens, including Pseudomonas aeruginosa, is a challenge facing many cystic fibrosis (CF) centres. Viable P aeruginosa are contained in aerosols produced during coughing, raising the possibility of airborne transmission.

Methods Using purpose-built equipment, we measured viable P aeruginosa in cough aerosols at 1, 2 and 4 m from the subject (distance) and after allowing aerosols to age for 5, 15 and 45 min in a slowly rotating drum to minimise gravitational settling and inertial impaction (duration). Aerosol particles were captured and sized employing an Anderson Impactor and cultured using conventional microbiology. Sputum was also cultured and lung function and respiratory muscle strength measured.

Results Nineteen patients with CF, mean age 25.8 (SD 9.2) years, chronically infected with P aeruginosa, and 10 healthy controls, 26.5 (8.7) years, participated. Viable P aeruginosa were detected in cough aerosols from all patients with CF, but not from controls; travelling 4 m in 17/18 (94%) and persisting for 45 min in 14/18 (78%) of the CF group. Marked inter-subject heterogeneity of P aeruginosa aerosol colony counts was seen and correlated strongly (r=0.73-0.90) with sputum bacterial loads. Modelling decay of viable P aeruginosa in a clinic room suggested that at the recommended ventilation rate of two air changes per hour almost 50 min were required for 90% to be removed after an infected patient left the room.

Conclusions: Viable P aeruginosa in cough aerosols travel further and last longer than recognised previously, providing additional evidence of airborne transmission between patients with CF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using a before and after study design, we compared protocolised weaning from mechanical ventilation with usual non-protocolised practice in intensive care. Outcomes (duration of mechanical ventilation, duration of intubation, intensive care stay) and complications (re-intubations, tracheostomy, mortality) were compared between baseline (Phase I) and following implementation of protocolised weaning (Phase II). Over the same period, we collected data in a second (reference) unit to monitor practice changes over time. In the intervention unit, outcomes were longer in Phase II compared with Phase I (all p < 0.005). When adjusted for admission APACHE II score and diagnostic category, only intensive care stay remained significantly longer (p = 0.002). There were significantly more tracheostomies in Phase II (p = 0.004). The reference unit demonstrated no statistically significant differences in study outcomes or complications between Phases. Protocolised weaning did not reduce the duration of mechanical ventilation and was not associated with an increased rate of re-intubation or intensive care unit mortality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing energy efficiency in the residential sector, while maintaining adequate home ventilation for health and well-being, is proving to be a challenge. This study assesses the efficacy of passive ventilation strategies designed to comply with building regulations and imposed after housing energy-efficiency retrofits. In particular, it focuses on the provision of ventilation using background through-wall vents, which remains a common strategy in a number of European countries including Ireland and the UK, where vent sizes, related to floor area, are stipulated in building regulations. A collective of social housing, with background through-wall vents installed post thermal retrofit, is taken as a case study. These homes are modelled to interrogate the impact of the passive ventilation strategy on house air exchange rate and thermal heating energy loads. The reaction of occupants to through-wall vent installation is decidedly negative and many block vents to limit thermal discomfort and heat loss. Simulation studies show significant external air ingress through vents. A wide range of effective air change rates are observed when vents are sized without reference to building airtightness, and significant energy penalties result for the leakier homes. This study evaluates the provision of passive through-wall ventilation as part of a retrofit programme and shows it to have a number of drawbacks that may impact on the health of the building and its occupants and ultimately be at odds with the aims of achieving energy efficiency in the residential sector.