88 resultados para GRoVar protocol (Geographic Routing with Variable transmission range)

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surrogate-based-optimization methods provide a means to achieve high-fidelity design optimization at reduced computational cost by using a high-fidelity model in combination with lower-fidelity models that are less expensive to evaluate. This paper presents a provably convergent trust-region model-management methodology for variableparameterization design models: that is, models for which the design parameters are defined over different spaces. Corrected space mapping is introduced as a method to map between the variable-parameterization design spaces. It is then used with a sequential-quadratic-programming-like trust-region method for two aerospace-related design optimization problems. Results for a wing design problem and a flapping-flight problem show that the method outperforms direct optimization in the high-fidelity space. On the wing design problem, the new method achieves 76% savings in high-fidelity function calls. On a bat-flight design problem, it achieves approximately 45% time savings, although it converges to a different local minimum than did the benchmark.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The construction and operation of a prism/variable-gap/sample system (or variable-gap Otto coupler) for the excitation of surface electromagnetic modes is reported. This system has been used for the observation and characterization of surface plasmon polaritons on thin film structures. The initial alignment of prism and sample is performed under gravity and the subsequent gap variation is performed by means of a single actuator operating a flexure stage on which the prism is mounted. The flexure stage ensures the maintenance of good parallelism between sample and prism as the gap dimension is varied. The coupler has also served as a prototype, in terms of design principle, for the construction of a more sophisticated, variable-gap Otto coupler that can operate in vacuum at temperatures from ambient to 85 K. (C) 2000 American Institute of Physics. [S0034-6748(00)02311-X].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we discuss and evaluate two proposed metro wavelength division multiplexing (WDM) ring network architectures for variable-length packet traffic in storage area networks (SANs) settings. The paper begins with a brief review of the relevant architectures and protocols in the literature. Subsequently, the network architectures along with their medium access control (MAC) protocols are described. Performance of the two network architectures is studied by means of computer simulation in terms of their queuing delay, node throughput and proportion of packets dropped. The network performance is evaluated under symmetric and asymmetric traffic scenarios with Poisson and self-similar traffic. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing demand for fast air transportation around the clock
has increased the number of night flights in civil aviation over
the past few decades. In night aviation, to land an aircraft, a
pilot needs to be able to identify an airport. The approach
lighting system (ALS) at an airport is used to provide
identification and guidance to pilots from a distance. ALS
consists of more than $100$ luminaires which are installed in a
defined pattern following strict guidelines by the International
Civil Aviation Organization (ICAO). ICAO also has strict
regulations for maintaining the performance level of the
luminaires. However, once installed, to date there is no automated
technique by which to monitor the performance of the lighting. We
suggest using images of the lighting pattern captured using a camera
placed inside an aircraft. Based on the information contained
within these images, the performance of the luminaires has to be
evaluated which requires identification of over $100$ luminaires
within the pattern of ALS image. This research proposes analysis
of the pattern using morphology filters which use a variable
length structuring element (VLSE). The dimension of the VLSE changes
continuously within an image and varies for different images.
A novel
technique for automatic determination of the VLSE is proposed and
it allows successful identification of the luminaires from the
image data as verified through the use of simulated and real data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: PET/CT scanning can determine suitability for curative therapy and inform decision making when considering radical therapy in patients with non-small cell lung cancer (NSCLC). Metastases to central mediastinal lymph nodes (N2) may alter such management decisions. We report a 2 year retrospective series assessing N2 lymph node staging accuracy with PET/CT compared to pathological analysis at surgery.

METHODS: Patients with NSCLC attending our centre (excluding those who had induction chemotherapy) who had staging PET/CT scans and pathological nodal sampling between June 2006 and June 2008 were analysed. For each lymph node assessed pathologically, the corresponding PET/CT status was determined. 64 patients with 200 N2 lymph nodes were analysed.

RESULTS: Sensitivity of PET/CT scans for indentifying involved N2 lymph nodes was
39%, specificity 96% and overall accuracy 90%. For individual lymph node analysis, logistic regression demonstrated a significant linear association between PET/CT sensitivity and time from scanning to surgery (p=0.031) but not for specificity and accuracy. Those scanned <9 weeks before pathological sampling were significantly more sensitive (64% >9 weeks, 0% ≥ 9 weeks, p=0.013) and more accurate (94% <9 weeks, 81% ≥ 9 weeks, p=0.007). Differences in specificity were not seen (97% <9 weeks, 91% ≥ 9 weeks, p=0.228). No significant difference in specificity was found at any time point.

CONCLUSIONS: We recommend that if a PET/CT scan is older than 9 weeks, and management would be altered by the presence of N2 nodes, re-staging of the
mediastinum should be undertaken.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The schistosome blood flukes are some of the largest global causes of parasitic morbidity. Further study of the specific antibody response during schistosomiasis may yield the vaccines and diagnostics needed to combat this disease. Therefore, for the purposes of antigen discovery, sera and antibody-secreting cell (ASC) probes from semi-permissive rats and sera from susceptible mice were used to screen a schistosome protein microarray. Following Schistosoma japonicum infection, rats had reduced pathology, increased antibody responses and broader antigen recognition profiles compared with mice. With successive infections, rat global serological reactivity and the number of recognized antigens increased. The local antibody response in rat skin and lung, measured with ASC probes, increased after parasite migration and contributed antigen-specific antibodies to the multivalent serological response. In addition, the temporal variation of anti-parasite serum antibodies after infection and reinfection followed patterns that appear related to the antigen driving the response. Among the 29 antigens differentially recognized by the infected hosts were numerous known vaccine candidates, drug targets and several S. japonicum homologs of human schistosomiasis resistance markers-the tegument allergen-like proteins. From this set, we prioritized eight proteins that may prove to be novel schistosome vaccine and diagnostic antigens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Active surveillance is increasingly accepted as a treatment option for favorable-risk prostate cancer. Long-term follow-up has been lacking. In this study, we report the long-term outcome of a large active surveillance protocol in men with favorable-risk prostate cancer.

PATIENTS AND METHODS: In a prospective single-arm cohort study carried out at a single academic health sciences center, 993 men with favorable- or intermediate-risk prostate cancer were managed with an initial expectant approach. Intervention was offered for a prostate-specific antigen (PSA) doubling time of less than 3 years, Gleason score progression, or unequivocal clinical progression. Main outcome measures were overall and disease-specific survival, rate of treatment, and PSA failure rate in the treated patients.

RESULTS: Among the 819 survivors, the median follow-up time from the first biopsy is 6.4 years (range, 0.2 to 19.8 years). One hundred forty-nine (15%) of 993 patients died, and 844 patients are alive (censored rate, 85.0%). There were 15 deaths (1.5%) from prostate cancer. The 10- and 15-year actuarial cause-specific survival rates were 98.1% and 94.3%, respectively. An additional 13 patients (1.3%) developed metastatic disease and are alive with confirmed metastases (n = 9) or have died of other causes (n = 4). At 5, 10, and 15 years, 75.7%, 63.5%, and 55.0% of patients remained untreated and on surveillance. The cumulative hazard ratio for nonprostate-to-prostate cancer mortality was 9.2:1.

CONCLUSION: Active surveillance for favorable-risk prostate cancer is feasible and seems safe in the 15-year time frame. In our cohort, 2.8% of patients have developed metastatic disease, and 1.5% have died of prostate cancer. This mortality rate is consistent with expected mortality in favorable-risk patients managed with initial definitive intervention.