44 resultados para Fractional delay
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Background: Delay time from onset of symptoms of myocardial infarction to seeking medical assistance can have life- 31 threatening consequences. A number of factors have been associated with delay, but there is little evidence regarding the predictive 32 value of these indices. Aim: To explore potential predictors of patient delay from onset of symptoms to time medical assistance 33 was sought in a consecutive sample of patients admitted to CCU with acute myocardial infarction. Methods: The Cardiac Denial 34 of Impact Scale, Health Locus of Control Scale, Health Value Scale and Pennebaker Inventory of Limbic Languidness were 35 administered to 62 patients between 3 and 6 days after admission. Results: Attribution of symptoms to heart disease and health 36 locus of control had a significant predictive effect on patients seeking help within 60 min, while previous experience of heart 37 disease did not. Conclusion: Assisting individuals to recognise the potential for symptoms to have a cardiac origin is an important 38 objective. Interventions should take into account the variety of cognitive and behavioural factors involved in decision making.
Resumo:
We present calculations of the time delay between single and double ionization of helium, obtained from full-dimensionality numerical integrations of the helium-laser Schroedinger equation. The notion of a quantum mechanical time delay is defined in terms of the interval between correlated bursts of single and double ionization. Calculations are performed at 390 and 780 nm in laser intensities that range from 2 X 10^14 to 14 X 10^14 W /cm^2. We find results consistent with the rescattering model of double ionization but supporting its classical interpretation only at 780 nm.
Resumo:
This letter investigates the optimum decision delay and tap-length of the finite-length decision feedback equalizer. First we show that, if the feedback filter (FBF) length N-b is equal to or larger than the channel memory upsilon and the decision delay Delta is smaller than the feedforward filter (FFF) length N-f, then only the first Delta + 1 elements of the FFF can be nonzero. Based on this result we prove that the maximum effective FBF length is equal to the channel memory upsilon, and if N-b greater than or equal to upsilon and N-f is long enough, the optimum decision delay that minimizes the MMSE is N-f - 1.
Resumo:
We discuss the properties of the lifetime or the time-delay matrix Q(E) for multichannel scattering, which is related to the scattering matrix S(E) by Q = i?S(dS†/dE). For two overlapping resonances occurring at energies E with widths G(? = 1, 2), with an energy-independent background, only two eigenvalues of Q(E) are proved to be different from zero and to show typical avoided-crossing behaviour. These eigenvalues are expressible in terms of the four resonance parameters (E , G) and a parameter representing the strength of the interaction of the resonances. An example of the strong and weak interaction in an overlapping double resonance is presented for the positronium negative ion. When more than two resonances overlap (? = 1, ..., N), no simple representation of each eigenvalue has been found. However, the formula for the trace of the Q-matrix leads to the expression d(E) = -?arctan[(G/2)/(E - E)] + d(E) for the eigenphase sum d(E) and the background eigenphase sum d(E), in agreement with the known form of the state density. The formulae presented in this paper are useful in a parameter fitting of overlapping resonances. © 2006 IOP Publishing Ltd.
Resumo:
Side-channel attacks (SCA) threaten electronic cryptographic devices and can be carried out by monitoring the physical characteristics of security circuits. Differential Power Analysis (DPA) is one the most widely studied side-channel attacks. Numerous countermeasure techniques, such as Random Delay Insertion (RDI), have been proposed to reduce the risk of DPA attacks against cryptographic devices. The RDI technique was first proposed for microprocessors but it was shown to be unsuccessful when implemented on smartcards as it was vulnerable to a variant of the DPA attack known as the Sliding-Window DPA attack.Previous research by the authors investigated the use of the RDI countermeasure for Field Programmable Gate Array (FPGA) based cryptographic devices. A split-RDI technique wasproposed to improve the security of the RDI countermeasure. A set of critical parameters wasalso proposed that could be utilized in the design stage to optimize a security algorithm designwith RDI in terms of area, speed and power. The authors also showed that RDI is an efficientcountermeasure technique on FPGA in comparison to other countermeasures.In this article, a new RDI logic design is proposed that can be used to cost-efficiently implementRDI on FPGA devices. Sliding-Window DPA and realignment attacks, which were shown to beeffective against RDI implemented on smartcard devices, are performed on the improved RDIFPGA implementation. We demonstrate that these attacks are unsuccessful and we also proposea realignment technique that can be used to demonstrate the weakness of RDI implementations.
Resumo:
Background The use of portable fractional exhaled nitric oxide (FENO) devices is increasingly common in the diagnosis and management of allergic airways inflammation. Methods We tested two handheld FENO devices, to determine (a) if there was adequate intradevice repeatability to allow the use of single breath testing, and (b) if the devices could be used interchangeably. In a mixed pediatric population, including normal, asthmatic, and children with peanut allergies, 858 paired values were collected from the NIOX-MINO® and/or the NObreath® devices. Results The NIOX-MINO® showed excellent repeatability (mean difference of 0.1 with 95% limits of agreement between -7.93 to 7.72?ppb), while the NObreath® showed good repeatability (mean difference of -1.61 with 95% limits of agreement between -14.1 and 10.8?ppb). Intradevice repeatability was good but not adequate and the NIOX-MINO® systematically produced higher results than the NObreath® [mean difference of 7.8?ppb with 95% limits of agreement from -11.55 to 27.52?ppb (-33% to 290%)]. Conclusions Our results support the manufacturer's advice that single breath testing is appropriate for the NIOX-MINO®. NObreath® results indicate that the mean of more than one breath should be utilized. The devices cannot be used interchangeably. Pediatr Pulmonol. © 2011 Wiley Periodicals, Inc.