31 resultados para Flowable composite
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Objectives: To evaluate the placement of composite materials by new graduates using three alternative placement techniques.Methods: A cohort of 34 recently qualified graduates were asked to restore class II interproximal cavities in plastic teeth using three different techniques.
(i) A conventional incremental filling technique (Herculite XRV) using increments no larger than 2-mm with an initial layer on the cervical floor of the box of 1-mm.
(ii) Flowable bulk fill technique (Dentsply SDR) bulk fill placement in a 3-mm layer followed by an incremental fill of a microhybrid resin
(iii) Bulk fill (Kerr Sonicfill) which involved restorations placed in a 5-mm layer.
The operators were instructed in each technique, didactically and with a hands-on demonstration, prior to restoration placement.
All restorations were cured according to manufacturer’s recommendations. Each participant restored 3 teeth, 1 tooth per treatment technique.
The restorations were evaluated using modified USPHS criteria to assess both the marginal adaptation and the surface texture of the restorations. Blind evaluations were carried out independently by two examiners with the aid of magnification (loupes X2.5). Examiners were standardized prior to evaluation.
Results: Gaps between the tooth margins and the restoration or between the layers of the restoration were found in 13 of Group (i), 3 of Group (ii), and 4 of Group (iii)
Statistical analysis revealed a significant difference between the incrementally filled group (i) and the flowable bulk-fill group (ii) (p=0.0043) and between the incrementally filled (i) and the bulk fill groups (iii) (p=0.012) and no statistical difference (p=0.69) between the bulk filled groups Conclusions: Bulk fill techniques may result in a more satisfactory seal of the cavity margins when restoring with composite.
Resumo:
First-order time remaining until a moving observer will pass an environmental element is optically specified in two different ways. The specification provided by global tau (based on the pattern of change of angular bearing) requires that the element is stationary and that the direction of motion is accurately detected, whereas the specification provided by composite tau (based on the patterns of change of optical size and optical distance) does not require either of these. We obtained converging evidence,for our hypothesis. that observers are sensitive to composite tau in four experiments involving, relative judgments of, time to, passage with forced-choice methodology. Discrimination performance was enhanced in the presence of a local expansion component, while being unaffected when the detection of the direction of heading was impaired. Observers relied on the information carried in composite tau rather than on the information carried in its constituent components. Finally, performance was similar under conditions of observer motion and conditions of object motion. Because composite tau specifies first-order time remaining for a large number of situations, the different ways in which it may be detected are discussed.
Resumo:
This paper presents the results of an experimental study (the ultimate load capacity of composite metal decking/concrete floor slabs. Full-scale in situ testing of composite floor slabs was carried out in the Building Research Establishment's Large Building Test Facility (LBTF) at Cardington. A parallel laboratory test programme, which compared the behaviour of composite floor slabs strips, also carried out at Queen's University Belfast (QUB). Articular attention was paid to the contribution of compressive membrane action to the load carrying capacity. The results of both test programmes were compared with predictions by yield line theory and a theoretical prediction method in which the amount of horizontal restraint mid be assessed. The full-scale tests clearly demon-wed the significant contribution of compressive membrane effects to the load capacity of interior floor panels with a lesser contribution to edge/corner panels.
Resumo:
In this article we propose a technique for dual-band Class-E power amplifier design using composite right/left-handed transmission lines, CRLH TLs. Design equations are presented and design procedures are elaborated. Because of the nonlinear phase dispersion characteristic of CRLH TLs, the single previous attempt at applying this method to dual bond Class-E amplifier design was not sufficient to simultaneously satisfy, the minimum requirement of Class-E impedances at both the fundamental and the second harmonic frequencies. This article rectifies this situation. A design example illustrating the synthesis procedure for a 0.5W-5V dual band Class-E amplifier circuit simultaneously operated at 900 MHz and 2.4 GHz is given and compared with ADS simulation.
Resumo:
The aims of this work were to investigate the conversion of a marine alga into hydroxyapatite (HA), and furthermore to design a composite bone tissue engineering scaffold comprising the synthesised HA within a porous bioresorbable polymer. The marine alga Phymatolithon calcareum, which exhibits a calcium carbonate honeycomb structure, with a natural architecture of interconnecting permeable pores (microporosity 4-11 mu m), provided the initial raw material for this study. The objective was to convert the alga into hydroxyapatite while maintaining its porous morphology using a sequential pyrolysis and chemical synthesis processes. Semi-quantitative XRD analysis of the post-hydrothermal material (pyrolised at 700-750 degrees C), indicated that the calcium phosphate (CaP) ceramic most likely consisted of a calcium carbonate macroporous lattice, with hydroxyapatite crystals on the surface of the macropores. Cell visibility (cytotoxicity) investigations of osteogenic cells were conducted on the CaP ceramic (i.e., the material post-hydrothermal analysis) which was found to be non-cytotoxic and displayed good biocompatibility when seeded with MG63 cells. Furthermore, a hot press scaffold fabrication technique was developed to produce a composite scaffold of CaP (derived from the marine alga) in a polycaprolactone (PCL) matrix. A salt leaching technique was further explored to introduce macroporosity to the structure (50-200 mu m). Analysis indicated that the scaffold contained both micro/macroporosity and mechanical strength, considered necessary for bone tissue engineering applications. (C) 2008 Published by Elsevier B.V.