103 resultados para Failure of the dental prosthesis

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the 19th century, firms operating in the Anglo-Indian tea trade were organised using a variety ownership forms including the partnership, joint-stock and a combination of the two known as the Managing agency. Faced with both an increasing need for fixed capital and high agency costs caused by the distance between owners and managers, the firms adapted and increasingly adopted the hybrid managing agency model to overcome these problems. Using new data from Calcutta and Bengal Commercial Registers and detailed case studies of the Assam Company and Gillanders, Arbuthnot and Co, this paper demonstrates that British entrepreneurs did not see the choice of ownership as a dichotomy or firm boundaries as fixed, but instead innovatively drew on the strengths of different forms of ownership to compete and grow successfully.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study the scaling behaviors of a time-dependent fiber-bundle model with local load sharing. Upon approaching the complete failure of the bundle, the breaking rate of fibers diverges according to r(t)proportional to(T-f-t)(-xi) where T-f is the lifetime of the bundle and xi approximate to 1.0 is a universal scaling exponent. The average lifetime of the bundle [T-f] scales with the system size as N-delta, where delta depends on the distribution of individual fiber as well as the breakdown rule. [S1063-651X(99)13902-3].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interprofessional education (IPE) should help to promote a team-based approach to professional practice but there are barriers to its implementation including professional identity. The aim of this study was to use a qualitative research methodology to explore dental and dental care professional (DCP) students' perceptions of professional roles and identities in the dental team. Data were collected by means of focus groups from a purposive sample of dental and DCP students and were audio recorded, transcribed and analysed using an explanatory framework. Five common themes emerged around the issue of professional roles and identity in the dental team. The results indicate that professional identity was an important factor in team development and was determined by direct responsibility for patient care and by the amount of clinical experience acquired. Professional identity within a team context was perceived as different from professional identity per se. Dental students were found to lack confidence in their role as team leaders which was related to their lack of knowledge of team roles, responsibilities and experience. The role of the dental technician was perceived as 'outside' the dental team due to lack of patient interaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There has been a recent identification of a need for a New Business History. This discussion connects with the analytic narrative approach. By following this approach, the study of business history provides important implications for the conduct and institutional design of contemporary industrial policy. The approach also allows us to solve historical puzzles. The failure of the De Lorean Motor Company Limited (DMCL) is one specific puzzle. Journalistic accounts that focus on John De Lorean's alleged personality defects as an explanation for this failure miss the crucial institutional component. Moreover, distortions in the rewards associated with industrial policy, and the fact that the objectives of the institutions implementing the policy were not solely efficiency-based, led to increased opportunities for rent-seeking. Political economy solves the specific puzzle; by considering institutional dimensions, we can also solve the more general puzzle of why activist industrial policy was relatively unsuccessful in Northern Ireland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Infection remains a severe complication following a total hip replacement. If infection is suspected when revision surgery is being performed, additional gentamicin is often added to the cement on an ad hoc basis in an attempt to reduce the risk of recurrent infection.

Methods and results: In this in vitro study, we determined the effect of incorporating additional gentamicin on the mechanical properties of cement. We also determined the degree of gentamicin release from cement, and also the extent to which biofilms of clinical Staphylococcus spp. isolates form on cement in vitro. When gentamicin was added to unloaded cement (1–4 g), there was a significant reduction in the mechanical performance of the loaded cements compared to unloaded cement. A significant increase in gentamicin release from the cement over 72 h was apparent, with the amount of gentamicin released increasing significantly with each additional 1 g of gentamicin added. When overt infection was modeled, the incorporation of additional gentamicin did result in an initial reduction in bacterial colonization, but this beneficial effect was no longer apparent by 72 h, with the clinical strains forming biofilms on the cements despite the release of high levels of gentamicin.

Interpretation: Our findings indicate that the addition of large amounts of gentamicin to cement is unlikely to eradicate bacteria present as a result of an overt infection of an existing implant, and could result in failure of the prosthetic joint because of a reduction in mechanical performance of the bone cement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental static and fatigue tension-tension tests were carried out on 5HS/RTM6 composite intact coupons and coupons incorporating adhesively-bonded (FM300-2) stepped flush joints. The results show that the adhesive joint, which is widely used in repairs, significantly reduces the static strength as well as the fatigue life of the composite. Both, the static and the fatigue failure of the ‘repaired’ coupons occur at the adhesive joint and involve crack initiation and propagation. The latter is modelled using interface finite elements based on the decohezive zone approach. The material degradation in the interface constitutive law is described by a damage variable, which can evolve due to the applied loads as well as the number of fatigue cycles. The fatigue formulation, based on a published model, is adapted to fit the framework of the pseudotransient formulation that is used as a numerical tool to overcome convergence difficulties. The fatigue model requires three material parameters. Numerical tests show that a single set of these parameters can be used to recover, very accurately, the experimental S-N relationship. Sensitivity studies show that the results are not mesh dependent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rockall is a tiny granite knoll isolated in the stormy waters of the North Atlantic. It is not habitable and has of itself no economic value. However, given its location it has been a prize insofar as at one time it was thought its possession could bring control of an exclusive economic zone. Iceland, Ireland and Denmark laid claim in addition to the UK, which had annexed Rockall in 1955, the last territory to be taken into the British Empire. In 1972 Rockall was declared to be part of Scotland. However the United Nations Convention on the Laws of the Sea (1982) now precludes rocks incapable of supporting life to be awarded economic zones. Interest in Rockall then reverted to symbolism especially in its occupation by Greenpeace in 1997 when the global state of Waveland was declared from Rockall’s summit, with Rockall itself as the capital. Greenpeace stayed on Rockall longer than anybody else and a claim has been established to it thereby, but Waveland itself collapsed with the failure of the company that serviced its online presence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The prothrombin G20210A polymorphism is associated with a threefold-increased risk of venous thrombosis. There is considerable variation in the reported prevalence of this polymorphism within normal populations, ranging from 0 to 6.5%. The prevalence within the Irish population has not been determined. A restriction fragment length polymorphism (RFLP)-based assay is commonly used for the detection of the prothrombin 20210A allele. This assay does not include a control restriction digest fragment and, consequently, failure of the enzyme activity or lack of addition of enzyme to the sample cannot be distinguished from wild-type prothrombin. We developed a RFLP-based assay, which incorporates an invariant digest site, resulting in the generation of a control digest fragment. Furthermore, we developed a nested polymerase chain reaction (PCR) method for the amplification and digestion of poor-quality or low-concentration DNA. In the Irish population studied, five of 385 (1.29%) were heterozygous and one patient was homozygous for the prothrombin 20210A polymorphism. This is the first reported data on an Irish or Celtic population and suggests that the allele frequency is similar to Anglo-Saxon populations. The nested PCR method successfully amplified and digested 100/100 (100%) of the archived samples; none of these samples could be analyzed by the standard single-round PCR method. In conclusion, nested PCR should be considered in the analysis of archived samples. Single-round PCR is appropriate for recently collected samples; however, an invariant control digest site should be incorporated in RFLP-based assays to validate the integrity of the digestion enzyme and limit the risk of false-negative results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case report details the successful rehabilitation of an edentulous patient using a complete upper prosthesis and a lower implant retained overdenture. The provision of care was split between a specialist centre and a primary care setting. This approach reduced inconvenience to the patient. Modern surgical and prosthodontic techniques also reduced the total delivery time. After initial consultation a new set of complete dentures was prescribed with changes in design to the originals. The patient was also planned for placement of two mandibular implants to stabilise and retain the mandibular denture. The first line of treatment involved provision of a new set of dentures constructed by the patient's general dental practitioner. Dental implants were then placed in a specialist centre and the patient returned to the dental practice for attachment of the lower denture to the dental implants. The benefits and success of mandibular implant retained dentures are well documented. With delivery of the overdenture, the patient reported increased satisfaction with his prostheses which allowed him to eat a greater range of foods and enabled him to feel confident when speaking and socialising.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: This systematic review aimed to report and explore the survival of dental veneers constructed from non-feldspathic porcelain over 5 and 10 years.

MATERIALS AND METHODS: A total of 4,294 articles were identified through a systematic search involving all databases in the Cochrane Library, MEDLINE (OVID), EMBASE, Web of Knowledge, specific journals (hand-search), conference proceedings, clinical trials registers, and collegiate contacts. Articles, abstracts, and gray literature were sought by two independent researchers. There were no language limitations. One hundred sixteen studies were identified for full-text assessment, with 10 included in the analysis (5 qualitative, 5 quantitative). Study characteristics and survival (Kaplan-Meier estimated cumulative survival and 95% confidence interval [CI]) were extracted or recalculated. A failed veneer was one which required an intervention that disrupted the original marginal integrity, had been partially or completely lost, or had lost retention more than twice. A meta-analysis and sensitivity analysis of Empress veneers was completed, with an assessment of statistical heterogeneity and publication bias. Clinical heterogeneity was explored for results of all veneering materials from included studies.

RESULTS: Within the 10 studies, veneers were fabricated with IPS Empress, IPS Empress 2, Cerinate, and Cerec computer-aided design/computer-assisted manufacture (CAD/CAM) materials VITA Mark I, VITA Mark II, Ivoclar ProCad. The meta-analysis showed the pooled estimate for Empress veneers to be 92.4% (95% CI: 89.8% to 95.0%) for 5-year survival and 66% to 94% (95% CI: 55% to 99%) for 10 years. Data regarding other non-feldspathic porcelain materials were lacking, with only a single study each reporting outcomes for Empress 2, Cerinate, and various Cerec porcelains over 5 years. The sensitivity analysis showed data from one study had an influencing and stabilizing effect on the 5-year pooled estimate.

CONCLUSION: The long-term outcome (> 5 years) of non-feldspathic porcelain veneers is sparsely reported in the literature. This systematic review indicates that the 5-year cumulative estimated survival for etchable non-feldspathic porcelain veneers is over 90%. Outcomes may prove clinically acceptable with time, but evidence remains lacking and the use of these materials for veneers remains experimental.