8 resultados para Double pulse

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a systematic study of double pulse pumping of the Ni-like Sm x-ray laser at 73 Angstrom, currently the shortest wavelength saturated x-ray laser. It is found that the Sm x-ray laser output can change by orders of magnitude when the intensity ratio of the pumping pulses and their relative delay are varied. Optimum pumping conditions are found and interpreted in terms of a simple model. (C) 1999 American Institute of Physics. [S0021-8979(99)07102-9].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of two separate ultraintense laser pulses in laser-proton acceleration was compared to the single pulse case employing the same total laser energy. A double pulse profile, with the temporal separation of the pulses varied between 0.75-2.5 ps, was shown to result in an increased maximum proton energy and an increase in conversion efficiency to fast protons by up to a factor of 3.3. Particle-in-cell simulations indicate the existence of a two stage acceleration process. The second phase, induced by the main pulse preferentially accelerates slower protons located deeper in the plasma, in contrast to conventional target normal sheath acceleration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

1. Fast inward currents were elicited in freshly isolated sheep lymphatic smooth muscle cells by depolarization from a holding potential of -80 mV using the whole-cell patch-clamp technique. The currents activated at voltages positive to -40 mV and peaked at 0 mV. 2. When sodium chloride in the bathing solution was replaced isosmotically with choline chloride inward currents were abolished at all potentials. 3. These currents were very sensitive to tetrodotoxin (TTX). Peak current was almost abolished at 1 microM with half-maximal inhibition at 17 nM. 4. Examination of the voltage dependence of steady state inactivation showed that more than 90% of the current was available at the normal resting potential of these cells (-60 mV). 5. The time course of recovery from inactivation was studied using a double-pulse protocol and showed that recovery was complete within 100 ms with a time constant of recovery of 20 ms. 6. Under current clamp, action potentials were elicited by depolarizing current pulses. These had a rapid upstroke and a short duration and could be blocked with 1 microM TTX. 7. Spontaneous contractions of isolated rings of sheep mesenteric lymphatic vessels were abolished or significantly depressed by 1 microM TTX.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent progress using the VULCAN laser at the Rutherford Appleton Laboratory to pump X-ray lasing in nickel-like ions is reviewed. Double pulse pumping with similar to 100 ps pulses has been shown to produce significantly greater X-ray laser output than single pulses of duration 0.1-1 ns. With double pulse pumping, the main pumping pulse interacts with a pre-formed plasma created by a pre-pulse. The efficiency of lasing increases as there is a reduced effect of refraction of the X-ray laser beam due to smaller density gradients and larger gain volumes, which enable propagation of the X-ray laser beam along the full length of the target. The record shortest wavelength saturated laser at 5.9 nm has been achieved in Ni-like dysprosium using double pulse pumping of 75 ps duration from the VULCAN laser. A variant of the double pulse pumping using a single similar to 100 ps laser pulse and a superimposed short similar to 1 ps pulse has been found to further increase the efficiency of lasing by reducing the effects of over-ionisation during the gain period. The record shortest wavelength saturated laser pumped by a short similar to 1 ps pulse has been achieved in Ni-like samarium using the VULCAN laser operating in chirped pulse amplified (CPA) mode. Ni-like samarium lases at 7.3 nm. (C) 2000 Academie des sciences/Editions scientifiques et medicales Elsevier SAS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Double laser pulses of duration similar to 75 ps and short laser pulses similar to 1 ps superimposed on longer duration background pulses have been shown to efficiently pump lasing in Ne-like and Ni-like ions. For the 75 ps pumping, X-ray laser output without travelling wave pumping is shown to be well-described by a model of ASE output. With I ps pumping, the X-ray laser output with different velocity travelling wave pumping is well-fitted with an extension to the ASE model allowing for travelling wave excitation of the gain along the plasma line. The model is used to investigate the production of short (<1 ps) x-ray laser pulses and the effects of non-ideal travelling wave velocities on the X-ray laser output. Resonance line spectra of emission perpendicular to the plasma line are measured and simulated. It is shown that an accurate opacity model for the more intense Ne-like ions is needed to correctly simulate the spectra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Short pulses of 100 ps FWHM duration at 1.06 mu m wavelength are used as the pump source for driving the J = 0-1, 19.6 nm, Ne-like germanium X-ray laser. Different combinations of short pulses are investigated and quantitatively compared. Configurations investigated include a single pulse, double pulses at 400 ps and 800 ps separation, single pulses with prepulses and double pulses with prepulses. Data are presented in the form of integrated energy measurements, and supported by modelling. The most efficient short pulse configurations are shown to be orders of magnitude more effective than pumping with nanosecond duration pulses. (C) 1997 Elsevier Science B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The collimation of proton beams accelerated during ultra-intense laser irradiation of thin aluminum foils was measured experimentally whilst varying laser contrast. Increasing the laser contrast using a double plasma mirror system resulted in a marked decrease in proton beam divergence (20° to <10°), and the enhanced collimation persisted over a wide range of target thicknesses (50 nm–6 µm), with an increased flux towards thinner targets. Supported by numerical simulation, the larger beam divergence at low contrast is attributed to the presence of a significant plasma scale length on the target front surface. This alters the fast electron generation and injection into the target, affecting the resultant sheath distribution and dynamics at the rear target surface. This result demonstrates that careful control of the laser contrast will be important for future laser-driven ion applications in which control of beam divergence is crucial.