307 resultados para Delivery, Obstetric.

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To determine how long it takes from the decision to achieve delivery by non-elective caesarean section (DDI), the influence on this interval, and the impact on neonatal condition at birth. Design Twelve months prospective data collection on all non-elective caesarean sections. Methods Prospective collection of data relating to all caesarean sections in 1996 in a major teaching hospital obstetric unit was conducted, without the knowledge of the other clinicians providing clinical care. Details of the indication for section, the day and time of the decision and the interval till delivery were recorded as well as the seniority of the surgeon, and condition of the baby at birth. Results The mean time from decision-to-delivery for 100 emergency intrapartum caesarean sections was 42.9 minutes for fetal distress and 71.1 minutes for 230 without fetal distress (P<0.0001). For 22 'crash' sections the mean time from decision-to-delivery was 27.4 minutes; for 13 urgent antepartum deliveries for fetal reasons it was 124.7 minutes and for 21 with maternal reasons it was 97.4 minutes. The seniority of the surgeon managing the patient did not appear to influence the interval, nor did the time of day or day of the week when the delivery occurred. Intrapartum sections were quicker the more advanced the labour, and general anaesthesia was associated with shorter intervals than regional anaesthesia for emergency caesarean section for fetal distress (P<0.001). Babies born within one hour of the decision tended to be more acidaemic than those born later, irrespective of the indication for delivery. Babies tended to be in better condition when a time from decision-to-delivery was not recorded than those for whom the information had been recorded. Conclusion Fewer than 40% intrapartum deliveries by caesarean section for fetal distress were achieved within 30 minutes of the decision, despite that being the unit standard. There was, however, no evidence to indicate that overall an interval up to 120 minutes was detrimental to the neonate unless the delivery was a 'crash' caesarean section. These data thus do not provide evidence to sustain the recommendation of a standard of 30 minutes for intrapartum delivery by caesarean section.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Establish maternal preferences for a third-trimester ultrasound scan in a healthy, low-risk pregnant population.

Design: Cross-sectional study incorporating a discrete choice experiment.

Setting: A large, urban maternity hospital in Northern Ireland.

Participants: One hundred and forty-six women in their second trimester of pregnancy.

Methods: A discrete choice experiment was designed to elicit preferences for four attributes of a third-trimester ultrasound scan: health-care professional conducting the scan, detection rate for abnormal foetal growth, provision of non-medical information, cost. Additional data collected included age, marital status, socio-economic status, obstetric history, pregnancy-specific stress levels, perceived health and whether pregnancy was planned. Analysis was undertaken using a mixed logit model with interaction effects.

Main outcome measures: Women's preferences for, and trade-offs between, the attributes of a hypothetical scan and indirect willingness-to-pay estimates.

Results: Women had significant positive preference for higher rate of detection, lower cost and provision of non-medical information, with no significant value placed on scan operator. Interaction effects revealed subgroups that valued the scan most: women experiencing their first pregnancy, women reporting higher levels of stress, an adverse obstetric history and older women.

Conclusions: Women were able to trade on aspects of care and place relative importance on clinical, non-clinical outcomes and processes of service delivery, thus highlighting the potential of using health utilities in the development of services from a clinical, economic and social perspective. Specifically, maternal preferences exhibited provide valuable information for designing a randomized trial of effectiveness and insight for clinical and policy decision makers to inform woman-centred care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the prevalence of overweight and obesity, and the impact of body mass index (BMI) on maternal and neonatal outcomes, in a UK obstetric population.
Design: Retrospective study.
Setting: A tertiary referral unit in Northern Ireland.
Population: A total of 30 298 singleton pregnancies over an 8-year period, 2004–2011.
Methods: Women were categorised according to World Health Organization classification: underweight (BMI < 18.50 kg/m2); normal weight (BMI 18.50–24.99 kg/m2; reference group); overweight (BMI 25.00–29.99 kg/m2); obese class I (BMI 30.00–34.99 kg/m2); obese class II (BMI 35–39.99 kg/m2); and obese class III (BMI = 40 kg/m2). Maternal and neonatal outcomes were examined using logistic regression, adjusted for confounding variables.
Main outcome measures: Maternal and neonatal outcomes.
Results: Compared with women of normal weight, women who were overweight or obese class I were at significantly increased risk of hypertensive disorders of pregnancy (OR 1.9, 99% CI 1.7–2.3; OR 3.5, 99% CI 2.9–4.2); gestational diabetes mellitus (OR 1.7, 99% CI 1.3–2.3; OR 3.7, 99% CI 2.8–5.0); induction of labour (OR 1.2, 99% CI 1.1–1.3; OR 1.3, 99% CI 1.2–1.5); caesarean section (OR 1.4, 99% CI 1.3–1.5; OR 1.8, 99% CI 1.6–2.0); postpartum haemorrhage (OR 1.4, 99% CI 1.3–1.5; OR 1.8, 1.6–2.0); and macrosomia (OR 1.5, 99% CI 1.3–1.6; OR 1.9, 99% CI 1.6–2.2), with the risks increasing for obese classes II and III. Women in obese class III were at increased risk of preterm delivery (OR 1.6, 99% CI 1.1–2.5), stillbirth (OR 3.0, 99% CI 1.0–9.3), postnatal stay > 5 days (OR 2.1, 99% CI 1.5–3.1), and infant requiring admission to a neonatal unit (OR 1.6, 99% CI 1.0–2.6).
Conclusions: By categorising women into overweight and obesity subclassifications (classes I –III), this study clearly demonstrates an increasing risk of adverse outcomes across BMI categories, with women who are overweight also at significant risk.
Keywords Body mass index, maternal and neonatal outcomes,obesity, pregnancy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxybutynin, a drug of choice in the treatment of urinary incontinence, has low oral bioavailability due to extensive first-pass metabolism. A toxic metabolite, N-desethyloxybutynin, has been linked to adverse reactions to oral oxybutynin. This study, therefore, reports on the design of an oxybutynin intravaginal ring (IVR) of reservoir design, comprising an oxybutynin silicone elastomer core encased in a non-medicated silicone sheath, manufactured by reaction injection moulding at 50oC. An unusually high initial burst release of oxybutynin (42.7 mg in 24 h) was observed in vitro with a full length core (100 mg drug loading), with subsequent non-zero order drug release. Use of fractional segment cores substantially reduced the burst effect, yielding linear cumulative drug release versus time plots from days 2 to 14. Thus, a 1/8 fractional segment core gave a 24 h burst of 11.28 mg oxybutynin and, thereafter, zero order release at the target dose of 5 mg/day over 14 days. Two oxybutynin cores, each 1/16 of full length, gave a greater release than a single 1/8 core, due to core segment end effects resulting in an increased surface area for release. The burst release was investigated by determining drug solubilities in the propan-1-ol product of elastomer condensation cure (390 mg/ml) and in the elastomer itself (13.9-20.21 mg/ml, by direct extraction and indirect thermal methods). These high oxybutynin solubilities were considered the major contributors to the burst effect. It was concluded that use of a fractional segment core would allow development of a suitable oxybutynin reservoir IVR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The silicone elastomer solubilities of a range of drugs and pharmaceutical excipients employed in the development of silicone intravaginal drug delivery rings (polyethylene glycols, norethisterone acetate, estradiol, triclosan, oleyl alcohol, oxybutynin) have been determined using dynamic mechanical analysis. The method involves measuring the concentration-dependent decrease in the storage modulus associated with the melting of the incorporated drug/excipient, and extrapolation to zero change in storage modulus. The study also demonstrates the effect of drug/excipient concentrations on the mechanical stiffness of the silicone devices at 37°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TMC 120 (Dapivirine) is a potent non-nucleoside reverse transcriptase inhibitor that is presently being developed as a vaginal HIV microbicide. To date, most vaginal microbicides under clinical investigation have been formulated as single-dose semi-solid gels, designed for application to the vagina before each act of intercourse. However, a clear rationale exists for providing long-term, controlled release of vaginal microbicides in order to afford continuous protection against heterosexually transmitted HIV infection and to improve user compliance. In this study we report on the incorporation of various pharmaceutical excipients into TMC 120 silicone, reservoir-type intravaginal rings (IVRs) in order to modify the controlled release characteristics of the microbicide. The results demonstrate that TMC 120 is released in zero-order fashion from the rings over a 28-day period and that release parameters could be modified by the inclusion of release-modifying excipients in the IVR. The hydrophobic liquid excipient isopropyl myristate had little effect on steady-state daily release rates, but did increase the magnitude and duration of burst release in proportion to excipient loading in the IVR. By comparison, the hydrophobic liquid poly(dimethylsiloxane) had little effect on TMC 120 release parameters. A hydrophilic excipient, lactose, had the surprising effect of decreasing TMC 120 burst release while increasing the apparent steady-state daily release in a concentration-dependent manner. Based on previous cell culture data and vaginal physiology, TMC120 is released from the various ring formulations in amounts potentially capable of maintaining a protective vaginal concentration. It is further predicted that the observed release rates may be maintained for at least a period of 1 year from a single ring device. TMC 120 release profiles and the mechanical properties of rings could be modified by the physicochemical nature of hydrophobic and hydrophilic excipients incorporated into the IVRs.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: