69 resultados para Conical tubes

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is accepted that ventilator-associated pneumonia is a frequent cause of morbidity and mortality in intensive care patients. This study describes the physicochemical properties of novel surfactant coatings of the endotracheal tube and the resistance to microbial adherence of surfactant coated endotracheal tube polyvinylchloride (PVC). Organic solutions of surfactants containing a range of ratios of cholesterol and lecithin (0:100, 25:75, 50:50, 75:25, dissolved in dichloromethane) were prepared and coated onto endotracheal tube PVC using a multiple dip-coating process. Using modulated temperature differential scanning calorimetry it was confirmed that the binary surfactant systems existed as physical mixtures. The surface properties of both surfactant-coated and uncoated PVC, following treatment with either pooled human saliva or phosphate-buffered saline (PBS), were characterised using dynamic contact angle analysis. Following treatment with saliva, the contact angles of PVC decreased; however, those of the coated biomaterials were unaffected, indicating different rates and extents of macromolecular adsorption from saliva onto the coated and uncoated PVC. The advancing and receding contact angles of the surfactant-coated PVC were unaffected by sonication, thereby providing evidence of the durability of the coatings. The cell surface hydrophobicity and zeta potentials of isolates of Staphylococcus aureus and Pseudomonas aeruginosa, following treatment with either saliva or PBS, and their adherence to uncoated and surfactant-coated PVC (that had been pre-treated with saliva) were examined. Adherence of S. aureus and Ps. aeruginosa to surfactant-coated PVC at each successive time period (0.5, 1, 2, 4, 8 h) was significantly lower than to uncoated PVC, the extent of the reduction frequently exceeding 90%. Interestingly, the microbial anti-adherent properties of the coatings were dependent on the lecithin content. Based on the impressive microbial anti-adherence properties and durability of the surfactant coating on PVC following dip coatings, it is proposed that these systems may usefully reduce the incidence of ventilator-associated pneumonia when employed as luminal coatings of the endotracheal tube.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-cadence optical observations of an H-alpha blue-wing bright point near solar AR NOAA 10794 are presented. The data were obtained with the Dunn Solar Telescope at the National Solar Observatory/Sacramento Peak using a newly developed camera system, the RAPID DUAL IMAGER. Wavelet analysis is undertaken to search for intensity-related oscillatory signatures, and periodicities ranging from 15 to 370 s are found with significance levels exceeding 95%. During two separate microflaring events, oscillation sites surrounding the bright point are observed to twist. We relate the twisting of the oscillation sites to the twisting of physical flux tubes, thus giving rise to reconnection phenomena. We derive an average twist velocity of 8.1 km s(-1) and detect a peak in the emitted flux between twist angles of 180 degrees and 230 degrees.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of an ultraintense laser pulse with a conical target is studied by means of numerical particle-in-cell simulations in the context of fast ignition. The divergence of the fast electron beam generated at the tip of the cone has been shown to be a crucial parameter for the efficient coupling of the ignition laser pulse to the precompressed fusion pellet. In this paper, we demonstrate that a focused hot electron beam is produced at the cone tip, provided that electron currents flowing along the surfaces of the cone sidewalls are efficiently generated. The influence of various interaction parameters over the formation of these wall currents is investigated. It is found that the strength of the electron flows is enhanced for high laser intensities, low density targets, and steep density gradients inside the cone. The hot electron energy distribution obeys a power law for energies of up to a few MeV, with the addition of a high-energy Maxwellian tail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efficient guiding of 1-ps infrared laser pulses with power exceeding 10 TW has been demonstrated through hollow capillary tubes with 40- and 100-mu m internal diameters and lengths up to 10 mm, with transmission greater than 80% of the incident energy coupled into the capillary. The beam is guided via multiple reflections off a plasma formed on the walls of the guide by the pulse's rising edge, as inferred from optical probe measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Geochemical,spectrographic, microbiological and hydrogeologic studies at the ORIFRC site indicate that groundwater transport in structured media may behave as a system of parallel flow tubes. These tubes are preferred flowpaths that enable contaminant transport parallel to bedding planes (strike) over distances of 1000s of meters. A significant flux of groundwater is focused within an interval defined by the interface between the competent bedrock and overlying highly-weathered saprolite, commonly referred to as the"transition zone." Characteristics of this transition zone are dense fractures and the relative absence of weathering products (e.g. clays)results in a significantly higher permeability compared to both the overlying clay-saprolite and underlying bedrock. Several stratabound low seismic velocity zones located below the transition zone were identified during geophysics studies and were also determined to be fractured high permeability preferred contaminant transport pathways during subsequent drilling activities. XANES analysis of precipitates collected from these deeper flow zones indicate 95% or more of the U deposited is U(VI). Linear combination fitting of the EXAFS data shows that precipitates are ~51±5% U(VI)-carbonate-like phase (e.g., liebigite) and ~49±5% U(VI) associated with an iron oxide phase; inclusion of a third component in the fit suggests that up to 15% of the U(VI) may be associated with a phosphate phase or OH- phase (e.g.,schoepite). Although precipitates with similar U(VI)-carbonate and/or phosphate associations were identified in the transition zone pathways,there were also U(VI) complexes adsorbed to mineral surfaces that would tend to be more readily mobilized. Groundwater in the different flow tubes has been determined to consist of different water quality types that vary with the solid phase encountered (e.g., clays, carbonates, clastics) as contaminants migrate along the flow paths. This lateral and vertical variability in geochemistry, particularly pH, has a significant impact on microbiological community composition and activity. Ribosomal RNA gene analyses coupled with physiological and genomic analyses suggest that bacteria from the genus Rhodanobacter(a diverse population of denitrifiers that are moderately acid tolerant) have a high relative abundance in the acidic source zone at the ORIFRC site.Watershed-scale analysis across different flow paths/tubes revealed strong negative correlation between pH and the absolute and relative abundance of Rhodanobacter. Recent studies also confirmed that the ORIFRC site hosts a diverse fungal community, with significant differences observed between acidic (pH <5) and circumneutral (>5) wells. The lack of nitrous oxide reduction capability in fungi, and the detection of denitrification potential in slurry microcosms suggest that fungi may have aheretofore under appreciated role in biogeochemical transformations, with implications forsite remediation and greenhouse gas emissions. Further research is needed to determine if these organisms can influence U(VI) mobility either directly through immobilization or indirectly through the depletion of nitrate.In conclusion, additional studies are required to quantify the processes (e.g., solid phase reactions, recharge, diffusion, microbial interactions) that are occurring along the groundwater flow tubes identified at the ORIFRC so predictive models can be parameterized and used to assess long-term contaminant fate and transport and remedial options.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber-reinforced polymer (FRP) hollow tubes are used in structural applications, such as utility poles and pipelines. Concrete-filled FRP tubes (CFFTs) are also used as piles and bridge piers. Applications such as poles and marine piles are typically governed by cyclic bending. In this paper, the fatigue behavior of glass-FRP filament-wound tubes is studied using coupons cut from the tubes. Several coupon configurations were first examined in 24 tension and five compression monotonic loading tests. Fatigue tests were then conducted on 81 coupons to examine several parameters; namely, loading frequency as well as maximum-to-ultimate (max ult) and minimum-to-maximum (min max) stress ratios, including tension tension and tension compression, to simulate reversed bending. The study demonstrated the sensitivity of test results and failure mode to coupon configuration. The presence of compression loads reduced fatigue life, while increasing load frequency increased fatigue life. Stiffness degradation behavior was also established. To achieve at least one million cycles, it is recommended to limit (max ult) to 0.25. Models were used to simulate stiffness degradation and fatigue life curve of the tube. Fatigue life predictions of large CFFT beams showed good correlation with experimental results. © 2008 ASCE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Milling of plant and soil material in plastic tubes, such as microcentrifuge tubes, over-estimates carbon (C) and under-estimates nitrogen (N) concentrations due to the introduction of polypropylene into milled samples, as identified using Fourier-transform infra-red spectroscopy.

This study compares C and N concentrations of roots and soil milled in microcentrifuge tubes versus stainless steel containers, demonstrating that a longer milling time, greater milling intensity, smaller sample size and inclusion of abrasive sample material all increase polypropylene contamination from plastic tubes leading to overestimation of C concentrations by up to 8 % (0.08 g g(-1)).

Erroneous estimations of C and N, and other analytes, must be assumed after milling in plastic tubes and milling methods should be adapted to minimise such error.