8 resultados para Computer Generated Proofs
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Recent growth in the shape-from-shading psychophysics literature has been paralled by an increasing availability of computer graphics hardware and software, to the extent that most psychophysical studies in this area now employ computer lighting algorithms. The most widely used of algorithms is shape-from-shading psychophysics is the Phong lighting model. This model, and other shading models of its genre, produce readily ineterpretable imiages of three-dimensional scenes. However, such algorithms are only approximations of how light interacts with real objects in the natural environment. Nevertheless, the results from psychophysical experiments using these techniques have been used to infer the processes underlying the perception of shape-from-shading in natural environments. It is important to establish whether this substitution is ever valid. We report a series of experiments investigating whether two recently reported illusions seen computer-generated, Phond shaded images occur for solid objects under real illuminants. The two illusions investigated are three-dimensional curvature contrast and the illuminant-position effect on perceived curvature. We show that both effects do occur for solid objects, and that the magnitude of these effects are equivalent regardless of whether subjects are presented with ray traced or solid objects.
Resumo:
Computer-assisted topology predictions are widely used to build low-resolution structural models of integral membrane proteins (IMPs). Experimental validation of these models by traditional methods is labor intensive and requires modifications that might alter the IMP native conformation. This work employs oxidative labeling coupled with mass spectrometry (MS) as a validation tool for computer-generated topology models. ·OH exposure introduces oxidative modifications in solvent-accessible regions, whereas buried segments (e.g., transmembrane helices) are non-oxidizable. The Escherichia coli protein WaaL (O-antigen ligase) is predicted to have 12 transmembrane helices and a large extramembrane domain (Pérez et al., Mol. Microbiol. 2008, 70, 1424). Tryptic digestion and LC-MS/MS were used to map the oxidative labeling behavior of WaaL. Met and Cys exhibit high intrinsic reactivities with ·OH, making them sensitive probes for solvent accessibility assays. Overall, the oxidation pattern of these residues is consistent with the originally proposed WaaL topology. One residue (M151), however, undergoes partial oxidation despite being predicted to reside within a transmembrane helix. Using an improved computer algorithm, a slightly modified topology model was generated that places M151 closer to the membrane interface. On the basis of the labeling data, it is concluded that the refined model more accurately reflects the actual topology of WaaL. We propose that the combination of oxidative labeling and MS represents a useful strategy for assessing the accuracy of IMP topology predictions, supplementing data obtained in traditional biochemical assays. In the future, it might be possible to incorporate oxidative labeling data directly as constraints in topology prediction algorithms.
Resumo:
A description of the uses of computer-generated noise in my instrumental scores and guided improvisations.
Resumo:
Abstract
Background Physical inactivity is a major public health concern, and more innovative approaches are urgently needed to address it. The UK Government supports the use of incentives and so-called nudges to encourage healthy behaviour changes, and has encouraged business sector involvement in public health through the Public Health Responsibility Deal. To test the effectiveness of provision of incentives to encourage adults to increase their physical activity, we
recruited 406 adults from a workplace setting (office-based) to take part in an assessor-blind randomised controlled trial.
Methods
We developed the physical activity loyalty card scheme, which integrates a novel physical activity tracking system with web-based monitoring (palcard). Participants were recruited from two buildings at Northern Ireland’s main
government offices and were randomly allocated (grouped by building [n=2] to reduce contamination) to either incentive group (n=199) or no incentive group (n=207). We included participants aged 16–65 years, based at the worksite 4 days or more per week and for 6 h or more per day, and able to complete 15 min of moderate-paced walking (self-report). Exclusion criteria included having received specific advice by a general practitioner not to exercise. A statistician not involved in administration of the trial prepared a computer-generated random allocation sequence. Random assignments were placed in individually numbered, sealed envelopes by the statistician to ensure concealment of allocation. Only the assessor was masked to assignment. Sensors were placed along footpaths and the gym in the workplace. Participants scanned their loyalty card at the sensor when undertaking physical activity (eg, walking), which logged activity. Participants in the incentive group monitored their physical activity, collected points, and received rewards (retail vouchers) for minutes of physical activity completed over the 12-week intervention. Rewards were vouchers sponsored by local retailers. Participants in the no incentive group used their loyalty card to self-monitor their physical activity but were not able to earn points or receive rewards. The primary outcome was change in minutes of moderate to vigorous physical activity with the Global Physical Activity Questionnaire, measured at baseline, week 12, and 6 months. Activity was objectively measured with the tracking system over the 12-week intervention. Mann Whitney U tests were done to assess change between groups.
Findings
The mean age of participants was 43·32 years (SD 9·37), and 272 (67%) were women. We obtained follow-up data from 353 (87%) participants at week 12 and 341 (84%) at 6 months. At week 12, participants in the incentive group increased moderate to vigorous physical activity by a median of 60 min per week (IQR –10 to 120) compared with 30 min per week (–60 to 90) in the no incentive group (p=0·05). At 6 months, participants in the incentive group had
increased their moderate to vigorous physical activity by 30 min per week (–60 to 100) from baseline compared with 0 min per week (–115 to 1110) in the no incentive group (p=0·099). We noted no significant differences between groups
for use of loyalty card (p=0·18). Participants in the incentive group recorded a mean of 60·22 min (95% CI 50·90–69·55) of physical activity per week with their loyalty card on week 1 and 23·56 min (17·06–30·06) at week 12, which was similar to that for those in the no incentive group (59·74 min, 51·24–68·23, at week 1; 20·25 min, 14·45–26·06, at week 12; p=0·94 for differences between groups at week 1; p=0·45 for differences between groups at week 12).
Interpretation:
Financial incentives showed a short-term behaviour change in physical activity. This innovative study contributes to the necessary evidence base, and has important implications for physical activity promotion and business engagement in health. The optimum incentive-based approach needs to be established. Results should be interpreted with some caution as the analyses of secondary outcomes were not adjusted for multiple comparisons.
Resumo:
Superimposition is built on a live-scoring system. Computer animated graphics combined with computer generated algorithms produce the score in real time based on preferences input by the composer. Notably, this system introduces a methodology for eliciting complex and coordinated rhythms from instrumentalists through notation generated in real time. This work also incorporates a system for live electronics and live sampling and processing.
Resumo:
BACKGROUND: Patient-reported outcomes (PROs) might detect more toxic effects of radiotherapy than do clinician-reported outcomes. We did a quality of life (QoL) substudy to assess PROs up to 24 months after conventionally fractionated or hypofractionated radiotherapy in the Conventional or Hypofractionated High Dose Intensity Modulated Radiotherapy in Prostate Cancer (CHHiP) trial.
METHODS: The CHHiP trial is a randomised, non-inferiority phase 3 trial done in 71 centres, of which 57 UK hospitals took part in the QoL substudy. Men with localised prostate cancer who were undergoing radiotherapy were eligible for trial entry if they had histologically confirmed T1b-T3aN0M0 prostate cancer, an estimated risk of seminal vesicle involvement less than 30%, prostate-specific antigen concentration less than 30 ng/mL, and a WHO performance status of 0 or 1. Participants were randomly assigned (1:1:1) to receive a standard fractionation schedule of 74 Gy in 37 fractions or one of two hypofractionated schedules: 60 Gy in 20 fractions or 57 Gy in 19 fractions. Randomisation was done with computer-generated permuted block sizes of six and nine, stratified by centre and National Comprehensive Cancer Network (NCCN) risk group. Treatment allocation was not masked. UCLA Prostate Cancer Index (UCLA-PCI), including Short Form (SF)-36 and Functional Assessment of Cancer Therapy-Prostate (FACT-P), or Expanded Prostate Cancer Index Composite (EPIC) and SF-12 quality-of-life questionnaires were completed at baseline, pre-radiotherapy, 10 weeks post-radiotherapy, and 6, 12, 18, and 24 months post-radiotherapy. The CHHiP trial completed accrual on June 16, 2011, and the QoL substudy was closed to further recruitment on Nov 1, 2009. Analysis was on an intention-to-treat basis. The primary endpoint of the QoL substudy was overall bowel bother and comparisons between fractionation groups were done at 24 months post-radiotherapy. The CHHiP trial is registered with ISRCTN registry, number ISRCTN97182923.
FINDINGS: 2100 participants in the CHHiP trial consented to be included in the QoL substudy: 696 assigned to the 74 Gy schedule, 698 assigned to the 60 Gy schedule, and 706 assigned to the 57 Gy schedule. Of these individuals, 1659 (79%) provided data pre-radiotherapy and 1444 (69%) provided data at 24 months after radiotherapy. Median follow-up was 50·0 months (IQR 38·4-64·2) on April 9, 2014, which was the most recent follow-up measurement of all data collected before the QoL data were analysed in September, 2014. Comparison of 74 Gy in 37 fractions, 60 Gy in 20 fractions, and 57 Gy in 19 fractions groups at 2 years showed no overall bowel bother in 269 (66%), 266 (65%), and 282 (65%) men; very small bother in 92 (22%), 91 (22%), and 93 (21%) men; small bother in 26 (6%), 28 (7%), and 38 (9%) men; moderate bother in 19 (5%), 23 (6%), and 21 (5%) men, and severe bother in four (<1%), three (<1%) and three (<1%) men respectively (74 Gy vs 60 Gy, ptrend=0.64, 74 Gy vs 57 Gy, ptrend=0·59). We saw no differences between treatment groups in change of bowel bother score from baseline or pre-radiotherapy to 24 months.
INTERPRETATION: The incidence of patient-reported bowel symptoms was low and similar between patients in the 74 Gy control group and the hypofractionated groups up to 24 months after radiotherapy. If efficacy outcomes from CHHiP show non-inferiority for hypofractionated treatments, these findings will add to the growing evidence for moderately hypofractionated radiotherapy schedules becoming the standard treatment for localised prostate cancer.
FUNDING: Cancer Research UK, Department of Health, and the National Institute for Health Research Cancer Research Network.
Resumo:
BACKGROUND: Prostate cancer might have high radiation-fraction sensitivity that would give a therapeutic advantage to hypofractionated treatment. We present a pre-planned analysis of the efficacy and side-effects of a randomised trial comparing conventional and hypofractionated radiotherapy after 5 years follow-up.
METHODS: CHHiP is a randomised, phase 3, non-inferiority trial that recruited men with localised prostate cancer (pT1b-T3aN0M0). Patients were randomly assigned (1:1:1) to conventional (74 Gy delivered in 37 fractions over 7·4 weeks) or one of two hypofractionated schedules (60 Gy in 20 fractions over 4 weeks or 57 Gy in 19 fractions over 3·8 weeks) all delivered with intensity-modulated techniques. Most patients were given radiotherapy with 3-6 months of neoadjuvant and concurrent androgen suppression. Randomisation was by computer-generated random permuted blocks, stratified by National Comprehensive Cancer Network (NCCN) risk group and radiotherapy treatment centre, and treatment allocation was not masked. The primary endpoint was time to biochemical or clinical failure; the critical hazard ratio (HR) for non-inferiority was 1·208. Analysis was by intention to treat. Long-term follow-up continues. The CHHiP trial is registered as an International Standard Randomised Controlled Trial, number ISRCTN97182923.
FINDINGS: Between Oct 18, 2002, and June 17, 2011, 3216 men were enrolled from 71 centres and randomly assigned (74 Gy group, 1065 patients; 60 Gy group, 1074 patients; 57 Gy group, 1077 patients). Median follow-up was 62·4 months (IQR 53·9-77·0). The proportion of patients who were biochemical or clinical failure free at 5 years was 88·3% (95% CI 86·0-90·2) in the 74 Gy group, 90·6% (88·5-92·3) in the 60 Gy group, and 85·9% (83·4-88·0) in the 57 Gy group. 60 Gy was non-inferior to 74 Gy (HR 0·84 [90% CI 0·68-1·03], pNI=0·0018) but non-inferiority could not be claimed for 57 Gy compared with 74 Gy (HR 1·20 [0·99-1·46], pNI=0·48). Long-term side-effects were similar in the hypofractionated groups compared with the conventional group. There were no significant differences in either the proportion or cumulative incidence of side-effects 5 years after treatment using three clinician-reported as well as patient-reported outcome measures. The estimated cumulative 5 year incidence of Radiation Therapy Oncology Group (RTOG) grade 2 or worse bowel and bladder adverse events was 13·7% (111 events) and 9·1% (66 events) in the 74 Gy group, 11·9% (105 events) and 11·7% (88 events) in the 60 Gy group, 11·3% (95 events) and 6·6% (57 events) in the 57 Gy group, respectively. No treatment-related deaths were reported.
INTERPRETATION: Hypofractionated radiotherapy using 60 Gy in 20 fractions is non-inferior to conventional fractionation using 74 Gy in 37 fractions and is recommended as a new standard of care for external-beam radiotherapy of localised prostate cancer.
FUNDING: Cancer Research UK, Department of Health, and the National Institute for Health Research Cancer Research Network.