21 resultados para Coaxial cables

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new quadrifilar antenna has been developed for generating circularly polarized backfire radiation. The antenna consists of two orthogonal rectangular conducting loops, each incorporating capacitive coupling and fed using either a single or two coaxial cables. Though the geometry is much simpler than a conventional quadrifilar helix antenna, the radiation pattern performance is very similar. Measured and simulated patterns are compared for two antennas with different feed arrangements. It is shown that the resonant structure can produce a cardioid pattern with a directivity of 4.5 dB (120 3-dB beamwidth) and a front-to-back ratio of more than 20 dB at the center operating frequency. A 10% impedance bandwidth (VSWR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper the parameters of cement grout affecting rheological behaviour and compressive strength are investigated. Factorial experimental design was adopted in this investigation to assess the combined effects of the following factors on fluidity, rheological properties, induced bleeding and compressive strength: water/binder ratio (W/B), dosage of superplasticiser (SP), dosage of viscosity agent (VA), and proportion of limestone powder as replacement of cement (LSP). Mini-slump test, Marsh cone, Lombardi plate cohesion meter, induced bleeding test, coaxial rotating cylinder viscometer were used to evaluate the rheology of the cement grout and the compressive strengths at 7 and 28 days were measured. A two-level fractional factorial statistical model was used to model the influence of key parameters on properties affecting the fluidity, the rheology and compressive strength. The models are valid for mixes with 0.35-0.42 W/B, 0.3-1.2% SP, 0.02-0.7% VA (percentage of binder) and 12-45% LSP as replacement of cement. The influences of W/B, SP, VA and LSP were characterised and analysed using polynomial regression which can identify the primary factors and their interactions on the measured properties. Mathematical polynomials were developed for mini-slump, plate cohesion meter, inducing bleeding, yield value, plastic viscosity and compressive strength as function of W/B, SP, VA and proportion of LSP. The statistical approach used highlighted the limestone powder effect and the dosage of SP and VA on the various rheological characteristics of cement grout

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A planar inductively coupled radio-frequency (rf) magnetic neutral loop discharge has been designed. It provides diagnostic access to both the main plasma production region as well as a remote plane for applications. Three coaxial coils are arranged to generate a specially designed inhomogeneous magnetic field structure with vanishing field along a ring in the discharge-the so-called neutral loop (NL). The plasma is generated by applying an oscillating rf electric field along the NL, induced through a four-turn, planar antenna operated at 13.56 MHz. Electron density and temperature measurements are performed under various parameter variations. Collisionless electron heating in the NL region allows plasma operation at comparatively low pressures, down to 10(-2) Pa, with a degree of ionization in the order of several per cent. Conventional plasma operation in inductive mode without applying the magnetic field is less efficient, in particular in the low pressure regime where the plasma cannot be sustained without magnetic fields.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method of injecting metallic elements into an electron-beam ion trap (EBIT) is described. The method is advantageous over the conventional coaxial and pulsed injection methods in two ways: (a) complicated switching of injection and extraction beams can be avoided when extracting beams of highly charged ions from the EBIT and (b) a beam of stable intensity can be achieved. This method may be applicable to any metallic elements or metallic compounds that have vapor pressures of similar to 0.1 Pa at a temperature lower than 1900 degrees C. We have employed this method for the extraction of highly charged ions of Bi, Er, Fe, and Ho. (c) 2006 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analytic formulation of dynamic electro-thermally induced nonlinearity is developed for a general resistive element, yielding a self-heating circuit model based on a fractional derivative. The model explains the 10 dB/decade slope of the intermodulation products observed in two-tone testing. Two-tone testing at 400 MHz of attenuators, microwave chip terminations, and coaxial terminations is reported with tone spacing ranging from 1 to 100 Hz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ground vehicle tests have been performed to evaluate the performance of a Passive Millimeter Wave (PMMW) imager in reduced visibility conditions and in particular, the ability to detect power lines and cables. A PMMW imager was
compared with Long Wave Infrared (LWIR) and visible imaging cameras. The three sensors were mounted on a Land Rover, together with GPS and digital recording system. All three sensors plus the GPS data were recorded simultaneously in order to provide direct comparisons. The vehicle collected imagery from a number of sites in the vicinity of Malvern, UK, in January, 2008. Imagery was collected both while the vehicle was stationary at specific sites
and while it was moving. Weather conditions during the data collection included clear, drizzle, rain and fog. Imagery was collected during the day, at night, and during dusk/dawn transition periods. The PMMW imager was a prototype which operated at 94 GHz and was based on a conically scanned folded Schmidt camera and the LWIR and visible sensors were commercial off the shelf items.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of annular aperture parameters on the optical transmission through arrays of coaxial apertures in a metal film on high refractive index substrates has been investigated experimentally and numerically. It is shown that the transmission resonances are related to plasmonic crystal effects rather than frequency cutoff behavior associated with annular apertures. The role of deviations from ideal aperture shape occurring during the fabrication process has also been studied. Annular aperture arrays are often considered in many applications for achieving high optical transmission through metal films and understanding of nanofabrication tolerances are important. (C) 2010 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cell and tissue patterning in plant embryo development is well documented. Moreover, it has recently been shown that successful embryogenesis is reliant on programmed cell death (PCD). The cytoskeleton governs cell morphogenesis. However, surprisingly little is known about the role of the cytoskeleton in plant embryogenesis and associated PCD. We have used the gymnosperm, Picea abies , somatic embryogenesis model system to address this question. Formation of the apical-basal embryonic pattern in P. abies proceeds through the establishment of three major cell types: the meristematic cells of the embryonal mass on one pole and the terminally differentiated suspensor cells on the other, separated by the embryonal tube cells. The organisation of microtubules and F-actin changes successively from the embryonal mass towards the distal end of the embryo suspensor. The microtubule arrays appear normal in the embryonal mass cells, but the microtubule network is partially disorganised in the embryonal tube cells and the microtubules disrupted in the suspensor cells. In the same embryos, the microtubule-associated protein, MAP-65, is bound only to organised microtubules. In contrast, in a developmentally arrested cell line, which is incapable of normal embryonic pattern formation, MAP-65 does not bind the cortical microtubules and we suggest that this is a criterion for proembryogenic masses (PEMs) to passage into early embryogeny. In embryos, the organisation of F-actin gradually changes from a fine network in the embryonal mass cells to thick cables in the suspensor cells in which the microtubule network is completely degraded. F-actin de-polymerisation drugs abolish normal embryonic pattern formation and associated PCD in the suspensor, strongly suggesting that the actin network is vital in this PCD pathway.