14 resultados para Clothing and dress measurements.
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Sampling and specimen preparation produce changes in mean effective stresses and pore water pressures, even with ‘perfect sampling’. The paper takes an existing simplified three-parameter cross-anisotropic elastic model and uses it to model these changes. The required ratio of cross-anisotropic parameters J/3G* can be obtained from standard CIU triaxial tests. If measurements are also made of suctions in unloaded specimens in the laboratory, then a combination of J/3G*, the measured suction, and the effective overburden pressure permits an estimation of the horizontal effective pressure and the K 0 ‘at rest’ coefficient. This can be helpful in numerical modelling that needs to start from in situ conditions, and in planning pressure levels for reconsolidation of clay specimens in the laboratory. Tests were done on Belfast Upper Boulder Clay from a depth of 28 m. Values of horizontal in situ effective stress estimated from these measurements compare favorably with conventional estimates of the ‘at rest’ coefficient K 0 and the overconsolidation ratio. Estimates of horizontal stress in London Clay were made using published data and the results compared with actual measurements. Again reasonable agreement was obtained.
Resumo:
We present measurements of the transverse and longitudinal coherence lengths of the fourth harmonic of a 1053-nm, 2.5-ps laser generated during high-intensity (up to 10(19) W cm(-2)) interactions with a solid target. Coherence lengths were measured by use of a Young's double-slit interferometer. The effective source size, as defined by the Van Cittert-Zernicke theorem, was found to be 10-12 mu m, and the coherence time was observed to be in the range 0.02-0.4 ps.
Resumo:
A time-resolved Langmuir probe technique is used to measure the dependence of the electron density, electron temperature, plasma potential and electron energy distribution function (EEDF) on the phase of the driving voltage in a RF driven parallel plate discharge. The measurements were made in a low-frequency (100-500 kHz), symmetrically driven, radio frequency discharge operating in H-2, D-2 and Ar at gas pressures of a few hundred millitorr. The EEDFs could not be represented by a single Maxwellian distribution and resembled the time averaged EEDFs reported in 13.56 MHz discharges. The measured parameters showed structure in their spatial and temporal dependence, generally consistent with a simple oscillating sheath model. Electron temperatures of less than 0.1 eV were measured during the phase of the RF cycle when both electrodes are negative with respect to the plasma.
Resumo:
The characterisation of soils for civil engineering purposes depends on removing sufficiently high-quality samples from the ground. Accurate evaluation of sample quality is therefore important if reliable design parameters are to be determined. This paper describes the use of unconfined shear wave velocity (V s) and suction (u r) measurements to assess sample quality rapidly in soft clay. Samples of varying quality from three well-characterised soft clay sites are initially assessed using conventional techniques, and their results compared with V s and u r measurements performed on the same samples. It is observed that the quality of samples indicated by these measurements is very similar to those inferred from traditional disturbance measures, with V s being the more reliable indicator. A tentative empirically derived criterion, based on samples tested in this project, is proposed to quantify sample disturbance combining both V s and u r measurements. Further work using this criterion on different materials is important so as to test its usefulness.
Resumo:
This work investigated the differences between multileaf collimator (MLC) positioning accuracy determined using either log files or electronic portal imaging devices (EPID) and then assessed the possibility of reducing patient specific quality control (QC) via phantom-less methodologies. In-house software was developed, and validated, to track MLC positional accuracy with the rotational and static gantry picket fence tests using an integrated electronic portal image. This software was used to monitor MLC daily performance over a 1 year period for two Varian TrueBeam linear accelerators, with the results directly compared with MLC positions determined using leaf trajectory log files. This software was validated by introducing known shifts and collimator errors. Skewness of the MLCs was found to be 0.03 ± 0.06° (mean ±1 standard deviation (SD)) and was dependent on whether the collimator was rotated manually or automatically. Trajectory log files, analysed using in-house software, showed average MLC positioning errors with a magnitude of 0.004 ± 0.003 mm (rotational) and 0.004 ± 0.011 mm (static) across two TrueBeam units over 1 year (mean ±1 SD). These ranges, as indicated by the SD, were lower than the related average MLC positioning errors of 0.000 ± 0.025 mm (rotational) and 0.000 ± 0.039 mm (static) that were obtained using the in-house EPID based software. The range of EPID measured MLC positional errors was larger due to the inherent uncertainties of the procedure. Over the duration of the study, multiple MLC positional errors were detected using the EPID based software but these same errors were not detected using the trajectory log files. This work shows the importance of increasing linac specific QC when phantom-less methodologies, such as the use of log files, are used to reduce patient specific QC. Tolerances of 0.25 mm have been created for the MLC positional errors using the EPID-based automated picket fence test. The software allows diagnosis of any specific leaf that needs repair and gives an indication as to the course of action that is required.
Resumo:
The entanglement of identity and personal attire in colonial settings is explored through consideration of a tattered set of clothes from late sixteenth-early seventeenth-century Ireland incorporating elements of Irish, English, and Scots fashion. Reconsideration of the clothing, recovered from a bog, provides a rare opportunity to explore the physical manifestations of processes of hybridity and mimesis, as well as the pragmatic accommodations of impoverishment and displacement in colonial settings. In addition to considering the role of material culture in colonial identity formation and negotiation, examination of what has become known as the Dungiven costume also speaks to the ongoing legacy of early modern colonial encounters, as the cultural associations of the garments, and by extension their past wearer(s), continue to be subjected to the politically charged nature of identity politics in contemporary Northern Ireland.
Resumo:
In this brief, a hybrid filter algorithm is developed to deal with the state estimation (SE) problem for power systems by taking into account the impact from the phasor measurement units (PMUs). Our aim is to include PMU measurements when designing the dynamic state estimators for power systems with traditional measurements. Also, as data dropouts inevitably occur in the transmission channels of traditional measurements from the meters to the control center, the missing measurement phenomenon is also tackled in the state estimator design. In the framework of extended Kalman filter (EKF) algorithm, the PMU measurements are treated as inequality constraints on the states with the aid of the statistical criterion, and then the addressed SE problem becomes a constrained optimization one based on the probability-maximization method. The resulting constrained optimization problem is then solved using the particle swarm optimization algorithm together with the penalty function approach. The proposed algorithm is applied to estimate the states of the power systems with both traditional and PMU measurements in the presence of probabilistic data missing phenomenon. Extensive simulations are carried out on the IEEE 14-bus test system and it is shown that the proposed algorithm gives much improved estimation performances over the traditional EKF method.