4 resultados para Cefuroxime

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bacterial infection primarily with Staphylococcus spp. and Propionibacterium acnes remains a significant complication following total hip replacement. In this in vitro study, we investigated the efficacy of gentamicin loading of bone cement and pre- and postoperative administration of cefuroxime in the prevention of biofilm formation by clinical isolates. High and low initial inocula, representative of the number of bacteria that may be present at the operative site as a result of overt infection and skin contamination, respectively, were used. When a high initial inoculum was used, gentamicin loading of the cement did not prevent biofilm formation by the 10 Staphylococcus spp. and the 10 P. acnes isolates tested. Similarly, the use of cefuroxime in the fluid phase with gentamicin-loaded cement did not prevent biofilm formation by four Staphylococcus spp. and four P. acnes isolates tested. However, when a low bacterial inoculum was used, a combination of both gentamicin-loaded cement and cefuroxime prevented biofilm formation by these eight isolates. Our results indicate that this antibiotic combination may protect against infection after intra-operative challenge with bacteria present in low numbers as a result of contamination from the skin but would not protect against bacteria present in high numbers as a result of overt infection of an existing implant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare the efficacy of gentamicin, nebulised via the endotracheal tube (ET), with that of parenteral cefotaxime or parenteral cefuroxime in preventing the formation of ET biofilm.

Setting: General intensive care units in two university teaching hospitals.

Design: The microbiology of ET biofilm from 36 ICU patients eligible to receive antibiotic prophylaxis was examined. Peak and trough tracheal concentrations of gentamicin, cefotaxime or cefuroxime were measured in each patient group, on the 2nd day of intubation.

Patients: Twelve patients received gentamicin (80 mg) nebulised in 4 ml normal saline every 8 h, 12 cefotaxime (1 g, 12 hourly) and 12 cefuroxime (750 mg, 8 hourly). Prophylaxis was continued for the duration of intubation.

Measurements and results: Samples of tracheal secretions were taken on the 2nd day of ventilation for determination of antibiotic concentrations. Following extubation, ETs were examined for the presence of biofilm. Pathogens considered to be common aetiological agents for VAP included Staphylococcus aureus, enterococci, Enterobacteriaceae and pseudomonads. While microbial biofilm was found on all ETs from the cephalosporin group, microbial biofilm of these micro-organisms was found on 7 of the 12 ET tubes from patients receiving cefotaxime [S. aureus (4), pseudomonads (1), Enterobacteriaceae (1), enterococcus (1)] and 8 of the 12 ET tubes from patients receiving cefuroxime [Enterobacteriaceae (6), P. aeruginosa (1) and enterococcus (1)]. While microbial biofilm was observed on five ETs from patients receiving nebulised gentamicin, none of these were from pathogens for ventilator-associated pneumonia (VAP). Tracheal concentrations of both cephalosporins were lower than those needed to inhibit the growth of pathogens recovered from ET tube biofilm. The median (and range) concentrations for cefotaxime were 0.90 (<0.23–1.31) mg/l and 0.28 (<0.23–0.58) mg/l for 2 h post-dose and trough samples, respectively. Two hours post-dose concentrations of cefuroxime (median and range) were 0.40 (0.34–0.83) mg/l, with trough concentrations of 0.35 (<0.22–0.47) mg/l. Tracheal concentrations (median and range) of gentamicin measured 1 h post-nebulisation were 790 (352–>1250) mg/l and then, before the next dose, were 436 (250–1000) mg/l.

Conclusion: Nebulised gentamicin attained high concentrations in the ET lumen and was more effective in preventing the formation of biofilm than either parenterally administered cephalosporin and therefore may be effective in preventing this complication of mechanical ventilation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new generation of water soluble tetrazolium salts have recently become available and in this study we compared a colorimetric assay developed using one of these salts, 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2, 4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8), with a previously developed 2,3-bis[2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide(XTT) colorimetric assay to determine which agent is most suitable for use as a colorimetric indicator in susceptibility testing. The MICs of 6 antibiotics were determined for 33 staphylococci using both colorimetric assays and compared with those obtained using the British Society for Antimicrobial Chemotherapy reference broth microdilution method. Absolute categorical agreement between the reference and test methods ranged from 79% (cefuroxime) to 100% (vancomycin) for both assays. No minor or major errors occurred using either assay with very major errors ranging from zero (vancomycin) to seven (cefuroxime). Analysis of the distribution of differences in the 1092 dilution MIC results revealed overall agreement, within the accuracy limits of the standard test ( 1 1092 dilution), using the XTT and WST-8 assays of 98% and 88%, respectively. Further studies on 31 ESBL-producing isolates were performed using the XTT method with absolute categorical agreement ranging from 87% (nitrofurantoin) to 100% (ofloxacin and meropenem). No errors were noted for either ofloxacin or meropenem with overall agreement of 91%. The data suggests that XTT is more reliable and accurate than WST-8 for use in a rapid antimicrobial susceptibility test. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new generation of water soluble tetrazolium salts have recently become available and in this study we compared a colorimetric assay developed using one of these salts, 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2, 4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8), with a previously developed 2,3-bis [2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide (XTT) colorimetric assay to determine which agent is most suitable for use as a colorimetric indicator in susceptibility testing. The MICs of 6 antibiotics were determined for 33 staphylococci using both colorimetric assays and compared with those obtained using the British Society for Antimicrobial Chemotherapy reference broth microdilution method. Absolute categorical agreement between the reference and test methods ranged from 79% (cefuroxime) to 100% (vancomycin) for both assays. No minor or major errors occurred using either assay with very major errors ranging from zero (vancomycin) to seven (cefuroxime). Analysis of the distribution of differences in the log2 dilution MIC results revealed overall agreement, within the accuracy limits of the standard test (± 1 log2 dilution), using the XTT and WST-8 assays of 98% and 88%, respectively. Further studies on 31 ESBL-producing isolates were performed using the XTT method with absolute categorical agreement ranging from 87% (nitrofurantoin) to 100% (ofloxacin and meropenem). No errors were noted for either ofloxacin or meropenem with overall agreement of 91%. The data suggests that XTT is more reliable and accurate than WST-8 for use in a rapid antimicrobial susceptibility test.