192 resultados para Cardiac Ultrasound

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This laboratory session provides hands-on experience for students to visualize the beating human heart with ultrasound imaging. Simple views are obtained from which students can directly measure important cardiac dimensions in systole and diastole. This allows students to derive, from first principles, important measures of cardiac function, such as stroke volume, ejection fraction, and cardiac output. By repeating the measurements from a subject after a brief exercise period, an increase in stroke volume and ejection fraction are easily demonstrable, potentially with or without an increase in left ventricular end-diastolic volume (which indicates preload). Thus, factors that affect cardiac performance can readily be discussed. This activity may be performed as a practical demonstration and visualized using an overhead projector or networked computers, concentrating on using the ultrasound images to teach basic physiological principles. This has proved to be highly popular with students, who reported a significant improvement in their understanding of Frank-Starling's law of the heart with ultrasound imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: The aim of this study is to assess the murine heart of normal embryos, neonates, and juveniles using high-frequency ultrasound. Methods: Diastolic function was measured with E/A ratio (E wave velocity/A wave velocity) and isovolumetric relaxation time (IRT), systolic function with isovolumetric contraction time (ICT), percentage fractional shortening (FS%), percentage ejection fraction (EF%). Global cardiac performance was quantified using myocardial performance index (MPI). Results: Isovolumetric relaxation time remained stable from E10.5 to 3 weeks. Systolic function (ICT) improved with gestation and remained stable from E18.5 onward. Myocardial performance index showed improvement in embryonic lift (0.82-0.63) and then stabilized from 1 to 3 week (0.60-0.58). Percentage ejection fraction remained high during gestation (77%-69%) and then decreased from the neonate to juvenile (68%-51%). Conclusion: The ultrasound biomicroscope allows for noninvasive in-depth assessment of cardiac function of embryos and pups. Detailed physiological and functional cardiac function readouts can be obtained, which is invaluable for comparison to mouse models of disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the epidemiology of out of hospital sudden cardiac death (OHSCD) in Belfast from 1 August 2003 to 31 July 2004.

Design: Prospective examination of out of hospital cardiac arrests by using the Utstein style and necropsy reports. World Health Organization criteria were applied to determine the number of sudden cardiac deaths.

Results: Of 300 OHSCDs, 197 (66%) in men, mean age (SD) 68 (14) years, 234 (78%) occurred at home. The emergency medical services (EMS) attended 279 (93%). Rhythm on EMS arrival was ventricular fibrillation (VF) in 75 (27%). The call to response interval (CRI) was mean (SD) 8 (3) minutes. Among patients attended by the EMS, 9.7% were resuscitated and 7.2% survived to leave hospital alive. The CRI for survivors was mean (SD) 5 (2) minutes and for non-survivors, 8 (3) minutes (p < 0.001). Ninety one (30%) OHSCDs were witnessed; of these 91 patients 48 (53%) had VF on EMS arrival. The survival rate for witnessed VF arrests was 20 of 48 (41.7%): all 20 survivors had VF as the presenting rhythm and CRI ? 7 minutes. The European age standardised incidence for OHSCD was 122/100 000 (95% confidence interval 111 to 133) for men and 41/100 000 (95% confidence interval 36 to 46) for women.

Conclusion: Despite a 37% reduction in heart attack mortality in Ireland over the past 20 years, the incidence of OHSCD in Belfast has not fallen. In this study, 78% of OHSCDs occurred at home.