59 resultados para Caesium 137, standard deviation

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radical abdominal radiotherapy in men runs the risk of impairing their fertility owing to scattered dose to the testes, outside of the treated volume. In patients for whom this is a concern it is important to be able to predict the dose to the testes before treatment in order to determine whether semen cryopreservation should be undertaken and testicular shielding performed during treatment. Measurements have been made on an anthropomorphic phantom to determine the magnitude of these doses for a four-field treatment consisting of an anterior-posterior parallel pair and a lateral parallel pair. A dataset is presented, which, together with a correction for patients size, allows an estimate of testicular dose to be made given only the photon energy, interfield distances and the distance from the testes to the nearest beam edge. Thermoluminescent dosimetry has been carried out in 17 patients to validate the use of the data tables. The results indicate that testicular doses may be estimated with a standard deviation corresponding to 1%-2% of the tumour dose, which is sufficient for the purpose of determining whether fertility is threatened by a planned treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Summary Target-controlled infusion systems have been shown to result in the administration of larger doses of propofol, which may result in delayed emergence and recovery from anaesthesia. The aim of this study was to investigate if this was due to a difference in the depth of hypnosis (using the bispectral index monitoring) between the manual and target controlled systems of administration. Fifty unpremedicated patients undergoing elective surgery were randomly allocated to have their anaesthesia maintained with manual or target-controlled propofol infusion schemes. In both groups, the rate of propofol administration was adjusted according to the standard clinical criteria while bispectral index scores were recorded by an observer not involved in the delivery of anaesthesia. The total dose of propofol used was higher in the target controlled group (mean 9.9 [standard deviation 1.6] compared with 8.1 [1.0] mg.kg.h in the manual group [p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The results of a study aimed at determining the most important experimental parameters for automated, quantitative analysis of solid dosage form pharmaceuticals (seized and model 'ecstasy' tablets) are reported. Data obtained with a macro-Raman spectrometer were complemented by micro-Raman measurements, which gave information on particle size and provided excellent data for developing statistical models of the sampling errors associated with collecting data as a series of grid points on the tablets' surface. Spectra recorded at single points on the surface of seized MDMA-caffeine-lactose tablets with a Raman microscope (lambda(ex) = 785 nm, 3 mum diameter spot) were typically dominated by one or other of the three components, consistent with Raman mapping data which showed the drug and caffeine microcrystals were ca 40 mum in diameter. Spectra collected with a microscope from eight points on a 200 mum grid were combined and in the resultant spectra the average value of the Raman band intensity ratio used to quantify the MDMA: caffeine ratio, mu(r), was 1.19 with an unacceptably high standard deviation, sigma(r), of 1.20. In contrast, with a conventional macro-Raman system (150 mum spot diameter), combined eight grid point data gave mu(r) = 1.47 with sigma(r) = 0.16. A simple statistical model which could be used to predict sigma(r) under the various conditions used was developed. The model showed that the decrease in sigma(r) on moving to a 150 mum spot was too large to be due entirely to the increased spot diameter but was consistent with the increased sampling volume that arose from a combination of the larger spot size and depth of focus in the macroscopic system. With the macro-Raman system, combining 64 grid points (0.5 mm spacing and 1-2 s accumulation per point) to give a single averaged spectrum for a tablet was found to be a practical balance between minimizing sampling errors and keeping overhead times at an acceptable level. The effectiveness of this sampling strategy was also tested by quantitative analysis of a set of model ecstasy tablets prepared from MDEA-sorbitol (0-30% by mass MDEA). A simple univariate calibration model of averaged 64 point data had R-2 = 0.998 and an r.m.s. standard error of prediction of 1.1% whereas data obtained by sampling just four points on the same tablet showed deviations from the calibration of up to 5%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In agroecosystems, most isotopic investigations of NO3- involve the use of tracers that are artificially enriched in 15N. Although the dual isotope composition of NO3-— d15N and d18O is especially beneficial for understanding the origin and fate of NO3-, its use for KCl-extractable soil NO3- has been hampered by the lack of a suitable analytical technique. Our objective was to test whether the denitrifier method, whereby NO3- is reduced to N2O before mass spectrometric analysis, can be used to determine the N and O isotopic composition of NO3- from 2 M KCl soil extracts. Several internationally accepted NO3- standards were dissolved in 2 M KCl, the conventional extractant for soil inorganic N, and inoculated with the bacterial strain Pseudomonas aureofaciens (ATCC no. 13985). The standard deviation of the NO3- standards analyzed did not exceed 0.2‰ for d15N and 0.3‰ for d18O values. After appropriate corrections, differences between our measured and consensus d15N and d18O values of standard NO3- generally were within the standard deviations given for the consensus values. Both d15N and d18O values were reproducible among separate analytical runs. The method was also tested on genuine 2 M KCl extracts from unfertilized and fertilized soils. Depending on N fertilization, the soils had distinct d15N and d18O values, which were attributed to amendment with NH4NO3 fertilizer. Hence, our data indicate that the denitrifier method provides a fast, reliable, precise, and accurate way of simultaneously analyzing the natural abundances of 15N and 18O in KCl-extractable soil NO3-.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To determine medical students’ self awareness and ability to discriminate right from left; to identify characteristics associated with this ability; and to identify any techniques used to aid discrimination. Design Questionnaire and psychometric study. Setting Undergraduate medical school, Northern Ireland. Participants 290 first year undergraduate students. Main outcome measure Medical students’ ability to discriminate right from left using the Bergen right-left discrimination test. Results Test scores ranged from 31 to 143 on a scale of 0- 144 (mean 112 (standard deviation 22.2)). Male students significantly outperformed female students (117.18 (26.96) v 110.80 (28.94)). Students who wanted to be surgeons performed significantly better than those who wanted to be general practitioners or medical doctors (119.87 (25.15) v 110.55 (27.36) v 112.50 (26.88)). The interaction effect for sex and career wishes was not significant (P=0.370). Students who used learnt techniques to help them discriminate scored significantly less than those who did not (P

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ability of Huntington's disease patients to co-ordinate their two hands with and without external cueing was investigated. Twelve Huntington's disease patients and sex- and age-matched controls performed a bimanual cranking task at two speeds (0.5 Hz, 1.5 Hz) and phase relationships (in-phase, anti-phase), with and without an external metronome cue. Data were sampled at 200 Hz, and raw displacement data for each hand, mean and standard deviation measures of the relative positions of the two hands and their velocities were then calculated. All participants could perform the in-phase movement, at both speeds; however, the Huntington's disease patients were more variable and less accurate than the control participants, particularly at the fast speed. While controls could perform the anti-phase movement, in which rotation of the cranks differed by 180 degrees at both speeds, Huntington's disease patients were unable to do so at either speed, reverting to the in-phase movement at the slow speed. An external metronome cue did not improve the performance of the Huntington's disease patients, which differentiated this group from patients suffering from Parkinson's disease. The Huntington's disease patients' inability to perform the anti-phase movement may be due to damage to the basal ganglia and its output regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bovine serum albumin (BSA) is a commonly used model protein in the development of pharmaceutical formulations. In order to assay its release from various dosage forms, either the bicinchoninic acid (BCA) assay or a more specific size-exclusion high performance liquid chromatography (SE-HPLC) method are commonly employed. However, these can give erroneous results in the presence of some commonly-used pharmaceutical excipients. We therefore investigated the ability of these methods to accurately determine BSA concentrations in pharmaceutical formulations that also contained various polymers and compared them with a new and compared with a new reverse-phase (RP)–HPLC technique. We found that the RP-HPLC technique was the most suitable method. It gave a linear response in the range of 0.5 -100 µg/ml with a correlation coefficient of 0.9999, a limit of detection of 0.11 µg/ml and quantification of 0.33 µg/ml. The performed ‘t’ test for the estimated and theoretical concentration indicated no significant difference between them providing the accuracy. Low % relative standard deviation values (0.8-1.39%) indicate the precision of the method. Furthermore, the method was used to quantify in vitro BSA release from polymeric freeze-dried formulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The radiation efficiency and resonance frequency of five compact antennas worn by nine individual test subjects was measured at 2.45 GHz in a reverberation chamber. The results show that, despite significant differences in body mass, wearable antenna radiation efficiency had a standard deviation less than 0.6 dB and the resonance frequency shift was less than 1% between test subjects. Variability in the radiation efficiency and resonance frequency shift between antennas was largely dependant on body tissue coupling which is related to both antenna geometry and radiation characteristics. The reverberation chamber measurements were validated using a synthetic tissue phantom and compared with results obtained in a spherical near field chamber and finite-difference time-domain (FDTD) simulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Policies suggest that primary care should be more involved in delivering cardiac rehabilitation. However, there is a lack of information about what is known in primary care regarding patients' invitation or attendance. Aim To determine, within primary care, how many patients are invited to and attend rehabilitation after myocardial infarction (MI), examine sociodemographic factors related to invitation, and compare quality of life between those who do and do not attend. Design of study Review of primary care paper and computer records; cross-sectional questionnaire. Setting Northern Ireland general practices (38); stratified sample, based on practice size and health board area. Method Patients, identified from primary care records, 12-16?weeks after a confirmed diagnosis of MI, were posted questionnaires, including a validated MacNew post-MI quality-of-life questionnaire. Practices returned anonymised data for non-responders. Results Information about rehabilitation was available for 332 of the 432 patients identified (76.9%): 162 (37.5%) returned questionnaires. Of the total sample, 54.4% (235/432) were invited and 37.0% (160/432) attended; of those invited, 68.1% (160/235) attended. Invited patients were younger than those not invited (mean age 63?years [standard deviation SD 16] versus 68.5?years [SD 16]); mean difference 5.5?years (95% confidence interval [CI] = 1.7 to 9.3). Among questionnaire responders, those who attended were younger and reported better emotional, physical, and social functioning than non-attenders (P = 0.01; mean differences 0.44 (95% CI = 0.11 to 0.77), 0.48 (95% CI = 0.10 to 0.85) and 0.54 (95% CI = 0.15 to 0.94) respectively). Conclusion Innovative strategies are needed to improve cardiac rehabilitation uptake, integration of hospital and primary care services, and healthcare professionals' awareness of patients' potential for health gain after MI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid analytical optical biosensor-based immunoassay was developed and validated for the detection of okadaic acid (OA) and its structurally related toxins from shellfish matrix. The assay utilizes a monoclonal antibody which binds to the OA group of toxins in order of their toxicities, resulting in a pseudofunctional assay. Single-laboratory validation of the assay for quantitative detection of OA determined that it has an action limit of 120 mu g/kg, a limit of detection of 31 mu g/kg, and a working range of 31-174 mu g/kg. The midpoint on the standard matrix calibration curve is 80 mu g/kg, half the current regulatory limit. Inter- and intra-assay studies of negative mussel samples spiked with various OA concentrations produced average coefficient of variation (CV) and standard deviation (SD) values of 7.9 and 10.1, respectively. The assay was also validated to confirm the ability to accurately codetect and quantify dinophysistoxin-1 (DTX-1), DTX-2, and DTX-3 from shellfish matrix. Alkaline hydrolysis was not required for the detection of DTX-3 from matrix. Excellent correlations with the data generated by the biosensor method and liquid chromatography/tandem mass spectrometry (LC/MS/MS) were obtained using a certified reference material (R-2 = 0.99), laboratory reference material, and naturally contaminated mussel samples (R-2 = 0.97). This new procedure could be used as a rapid screening procedure replacing animal-based tests for DSP toxins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To examine the association of sunlight exposure and antioxidant level with age-related macular degeneration (AMD). Methods: Four thousand seven hundred fifty-three participants aged 65 years or older in the European Eye Study underwent fundus photography, were interviewed for adult lifetime sunlight exposure, and gave blood for antioxidant analysis. Blue light exposure was estimated by combining meteorologic and questionnaire data. Results: Data on sunlight exposure and antioxidants were available in 101 individuals with neovascular AMD, 2182 with early AMD, and 2117 controls. No association was found between blue light exposure and neovascular or early AMD. Significant associations were found between blue light exposure and neovascular AMD in individuals in the quartile of lowest antioxidant level - vitamin C, zeaxanthin, vitamin E, and dietary zinc - with an odds ratio of about 1.4 for 1 standard deviation unit increase in blue light exposure. Higher odds ratios for blue light were observed with combined low antioxidant levels, especially vitamin C, zeaxanthin, and vitamin E (odds ratio, 3.7; 95% confidence interval, 1.6-8.9), which were also associated with early stages of AMD. Conclusions: Although it is not possible to establish causality between sunlight exposure and neovascular AMD, our results suggest that people in the general population should use ocular protection and follow dietary recommendations for the key antioxidant nutrients. ©2008 American Medical Association. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wear particle accumulation is one of the main contributors to osteolysis and implant failure in hip replacements. Altered kinematics produce significant differences in wear rates of hip replacements in simulator studies due to varying degrees of multidirectional motion. Gait analysis data from 153 hip-replacement patients 10-years post-operation were used to model two- and three-dimensional wear paths for each patient. Wear paths were quantified in two dimensions using aspect ratios and in three dimensions using the surface areas of the wear paths, with wear-path surface area correlating poorly with aspect ratio. The average aspect ratio of the patients wear paths was 3.97 (standard deviation ¼ 1.38), ranging from 2.13 to 10.86. Sixty percent of patients displayed aspect ratios between 2.50 and 3.99. However, 13% of patients displayed wear paths with aspect ratios 45.5, which indicates reduced multidirectional motion. The majority of total hip replacement (THR) patients display gait kinematics which produce multidirectional wear paths, but a significant minority display more linear paths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To study some of the interfacial properties of PtSi/Si diodes, Schottky structures were fabricated on (100) crystalline silicon substrates by conventional thermal evaporation of Pt on Si followed by annealing at different temperatures (from 400 degrees C to 700 degrees C) to form PtSi. The PtSi/n-Si diodes, all yielded Schottky barrier (SB) heights that are remarkably temperature dependent. The temperature range (20-290 K) over which the I-V characteristics were measured in the present study is broader with a much lower limit (20 K), than what is usually reported in literature. These variations in the barrier height are adequately interpreted by introducing spatial inhomogeneity into the barrier potential with a Gaussian distribution having a mean barrier of 0.76 eV and a standard deviation of 30 meV. Multi-frequency capacitance-voltage measurements suggest that the barrier is primarily controlled by the properties of the silicide-silicon interface. The forward C-V characteristics, in particular, show small peaks at low frequencies that can be ascribed to interface states rather than to a series resistance effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid surface plasmon resonance (SPR) screening assay has been developed for the combined detection of T-2 and HT-2 toxins in naturally contaminated cereals using a sensor chip coated with an HT-2 toxin derivative and a monoclonal antibody. The antibody raised against HT-2 displayed high cross-reactivity with T-2 toxin while there was no cross-reaction observed with other commonly occurring trichothecenes. A simple extraction procedure using 40% methanol was applied to baby food, breakfast cereal, and wheat samples prior to biosensor analysis. Limits of detection (LOD) for each matrix were determined as 25 mu g kg(-1) for baby food and breakfast cereal and 26 mu g kg(-1) for wheat. Intra-assay precision (n = 6) was calculated for each matrix. The results were expressed as the relative standard deviation and determined as 2.8% (100 mu g kg(-1)) and 1.8% (200 mu g kg(-1)) in breakfast cereal, 4.6% (50 mu g kg(-1)) and 3.6% (100 mu g kg(-1)) in wheat and 0.97% (25 mu g kg(-1)) and 6.3% (50 mu g kg(-1)) in baby food. Between run precision (n = 3) performed at the same levels yielded relative standard deviations of 6.7% and 3.9% for breakfast cereals, 3.3% and 1.6% for wheat and 6.8% and 0.08% for baby food, respectively. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The preparation and characterisation are described of a robust, reversible, hydrogen peroxide optical sensor, based on the fluorescent quenching of the dye ion-pair [Ru(bpy)(3)(2+)(Ph4B-)(2)], by O-2 produced by the catalytic breakdown of H2O2, utilizing the inorganic catalyst RuO2 center dot xH(2)O. The main feature of this system is the one-pot formulation of a coating ink that, when dried, forms an active single-layer fluorescence-based H2O2 sensor, demonstrably capable of detecting H2O2 over the range of 0.01 to 1 M, with a relative standard deviation of ca. 4% and a calculated lower limit of detection of 0.1 mM. These sensors are sterilisable, using dry-heat, and stable when stored over 40 days, without exhibiting any loss in sensitivity or response characteristics.