10 resultados para CCM

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Acute lung injury and the acute respiratory distress syndrome are characterized by noncardiogenic pulmonary edema, which can be assessed by measurement of extravascular lung water. Traditionally, extravascular lung water has been indexed to actual body weight (mL/kg). Because lung size is dependent on height rather than weight, we hypothesized indexing to predicted body weight may be a better predictor of mortality in acute lung injury/acute respiratory distress syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Acute respiratory distress syndrome (ARDS) is characterized by alveolar-capillary barrier damage. Matrix metalloproteinases (MMPs) are implicated in the pathogenesis of ARDS. In the Beta Agonists in Acute Lung Injury Trial, intravenous salbutamol reduced extravascular lung water (EVLW) in patients with ARDS at day 4 but not inflammatory cytokines or neutrophil recruitment. We hypothesized that salbutamol reduces MMP activity in ARDS.

Methods: MMP-1/-2/-3/-7/-8/-9/-12/-13 was measured in supernatants of distal lung epithelial cells, type II alveolar cells, and bronchoalveolar lavage (BAL) fluid from patients in the Beta Agonists in Acute Lung Injury study by multiplex bead array and tissue inhibitors of metalloproteinases (TIMPs)-1/-2 by enzyme-linked immunosorbent assay. MMP-9 protein and activity levels were further measured by gelatin zymography and fluorokine assay.

Measurements and Main Results: BAL fluid MMP-1/-2/-3 declined by day 4, whereas total MMP-9 tended to increase. Unexpectedly, salbutamol augmented MMP-9 activity. Salbutamol induced 33.7- and 13.2-fold upregulation in total and lipocalin-associated MMP-9, respectively at day 4, compared with 2.0- and 1.3-fold increase in the placebo group, p < 0.03. Salbutamol did not affect BAL fluid TIMP-1/-2. Net active MMP-9 was higher in the salbutamol group (4222 pg/mL, interquartile range: 513-7551) at day 4 compared with placebo (151 pg/mL, 124-2108), p = 0.012. Subjects with an increase in BAL fluid MMP-9 during the 4-day period had lower EVLW measurements than those in whom MMP-9 fell (10 vs. 17 mL/kg, p = 0.004): change in lung water correlated inversely with change in MMP-9, r = -.54, p = 0.0296. Salbutamol up-regulated MMP-9 and down-regulated TIMP-1/-2 secretion in vitro by distal lung epithelial cells. Inhibition of MMP-9 activity in cultures of type II alveolar epithelial cells reduced wound healing.

Conclusions: Salbutamol specifically up-regulates MMP-9 in vitro and in vivo in patients with ARDS. Up-regulated MMP-9 is associated with a reduction in EVLW. MMP-9 activity is required for alveolar epithelial wound healing in vitro. Data suggest MMP-9 may have a previously unrecognized beneficial role in reducing pulmonary edema in ARDS by improving alveolar epithelial healing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Endothelial function may be impaired in critical illness. We hypothesized that impaired endothelium-dependent vasodilatation is a predictor of mortality in critically ill patients.
Design: Prospective observational cohort study.
Setting: Seventeen-bed adult intensive care unit in a tertiary referral university teaching hospital. Patients: Patients were recruited within 24 hrs of admission to the intensive care unit.
Interventions: The SphygmoCor Mx system was used to derive the aortic augmentation index from radial artery pulse pressure waveforms. Endothelium-dependent vasodilatation was calculated as the change in augmentation index in response to an endothelium-dependent vasodilator (salbutamol).
Measurements and Main Results: Demographics, severity of illness scores, and physiological parameters were collected. Statistically significant predictors of mortality identified using single regressor analysis were entered into a multiple logistic regression model. Receiver operator characteristic curves were generated. Ninety-four patients completed the study. There were 80 survivors and 14 nonsurvivors. The Simplified Acute Physiology Score II, the Sequential Organ Failure Assessment score, leukocyte count, and endothelium-dependent vasodilatation conferred an increased risk of mortality. In logistic regression analysis, endothelium-dependent vasodilatation was the only predictor of mortality with an adjusted odds ratio of 26.1 (95% confidence interval [CI], 4.3-159.5). An endothelium-dependent vasodilatation value of 0.5% or less predicted intensive care unit mortality with a sensitivity of 79% (CI, 59-88%) and specificity of 98% (CI, 94-99%).
Conclusions: In vivo bedside assessment of endothelium-dependent vasodilatation is an independent predictor of mortality in the critically ill. We have shown it to be superior to other validated severity of illness scores with high sensitivity and specificity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impedance cardiogram recorded by an automated external defibrillator during cardiac arrest to facilitate emergency care by lay persons. Lay persons are poor at emergency pulse checks (sensitivity 84%, specificity 36%); guidelines recommend they should not be performed. The impedance cardiogram (dZ/dt) is used to indicate stroke volume. Can an impedance cardiogram algorithm in a defibrillator determine rapidly circulatory arrest and facilitate prompt initiation of external cardiac massage?

DESIGN: Clinical study.

SETTING: University hospital.

PATIENTS: Phase 1 patients attended for myocardial perfusion imaging. Phase 2 patients were recruited during cardiac arrest. This group included nonarrest controls.

INTERVENTIONS: The impedance cardiogram was recorded through defibrillator/electrocardiographic pads oriented in the standard cardiac arrest position.

MEASUREMENTS AND MAIN RESULTS: Phase 1: Stroke volumes from gated myocardial perfusion imaging scans were correlated with parameters from the impedance cardiogram system (dZ/dt(max) and the peak amplitude of the Fast Fourier Transform of dZ/dt between 1.5 Hz and 4.5 Hz). Multivariate analysis was performed to fit stroke volumes from gated myocardial perfusion imaging scans with linear and quadratic terms for dZ/dt(max) and the Fast Fourier Transform to identify significant parameters for incorporation into a cardiac arrest diagnostic algorithm. The square of the peak amplitude of the Fast Fourier Transform of dZ/dt was the best predictor of reduction in stroke volumes from gated myocardial perfusion imaging scans (range = 33-85 mL; p = .016). Having established that the two pad impedance cardiogram system could detect differences in stroke volumes from gated myocardial perfusion imaging scans, we assessed its performance in diagnosing cardiac arrest. Phase 2: The impedance cardiogram was recorded in 132 "cardiac arrest" patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with sensitivities and specificities (+/- exact 95% confidence intervals) of 89.1% (85.4-92.1) and 99.6% (99.4-99.7; training) and 81.1% (77.6-84.3) and 97% (96.7-97.4; validation).

CONCLUSIONS: The impedance cardiogram algorithm is a significant marker of circulatory collapse. Automated defibrillators with an integrated impedance cardiogram could improve emergency care by lay persons, enabling rapid and appropriate initiation of external cardiac massage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?

DESIGN: Animal study.

SETTING: University research laboratory.

SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.

INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).

MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).

CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.