63 resultados para Aqueous two-phase polymer systems

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose The aim of this work was to examine, for amorphous solid dispersions, how the thermal analysis method selected impacts on the construction of thermodynamic phase diagrams, and to assess the predictive value of such phase diagrams in the selection of optimal, physically stable API-polymer compositions. Methods Thermodynamic phase diagrams for two API/polymer systems (naproxen/HPMC AS LF and naproxen/Kollidon 17 PF) were constructed from data collected using two different thermal analysis methods. The “dynamic” method involved heating the physical mixture at a rate of 1 &[deg]C/minute. In the "static" approach, samples were held at a temperature above the polymer Tg for prolonged periods, prior to scanning at 10 &[deg]C/minute. Subsequent to construction of phase diagrams, solid dispersions consisting of API-polymer compositions representative of different zones in the phase diagrams were spray dried and characterised using DSC, pXRD, TGA, FTIR, DVS and SEM. The stability of these systems was investigated under the following conditions: 25 &[deg]C, desiccated; 25 &[deg]C, 60 % RH; 40 &[deg]C, desiccated; 40 &[deg]C, 60 % RH. Results Endset depression occurred with increasing polymer volume fraction (Figure 1a). In conjunction with this data, Flory-Huggins and Gordon-Taylor theory were applied to construct thermodynamic phase diagrams (Figure 1b). The Flory-Huggins interaction parameter (&[chi]) for naproxen and HPMC AS LF was + 0.80 and + 0.72, for the dynamic and static methods respectively. For naproxen and Kollidon 17 PF, the dynamic data resulted in an interaction parameter of - 1.1 and the isothermal data produced a value of - 2.2. For both systems, the API appeared to be less soluble in the polymer when the dynamic approach was used. Stability studies of spray dried solid dispersions could be used as a means of validating the thermodynamic phase diagrams. Conclusion The thermal analysis method used to collate data has a deterministic effect on the phase diagram produced. This effect should be considered when constructing thermodynamic phase diagrams, as they can be a useful tool in predicting the stability of amorphous solid dispersions.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Developing complex interventions for testing in randomised controlled trials is of increasing importance in healthcare planning. There is a need for careful design of interventions for secondary prevention of coronary heart disease (CHD). It has been suggested that integrating qualitative research in the development of a complex intervention may contribute to optimising its design but there is limited evidence of this in practice. This study aims to examine the contribution of qualitative research in developing a complex intervention to improve the provision and uptake of secondary prevention of CHD within primary care in two different healthcare systems.

Methods: In four general practices, one rural and one urban, in Northern Ireland and the Republic of Ireland, patients with CHD were purposively selected. Four focus groups with patients (N = 23) and four with staff (N = 29) informed the development of the intervention by exploring how it could be tailored and integrated with current secondary prevention activities for CHD in the two healthcare settings. Following an exploratory trial the acceptability and feasibility of the intervention were discussed in four focus groups (17 patients) and 10 interviews (staff). The data were analysed using thematic analysis.

Results: Integrating qualitative research into the development of the intervention provided depth of information about the varying impact, between the two healthcare systems, of different funding and administrative arrangements, on their provision of secondary prevention and identified similar barriers of time constraints, training needs and poor patient motivation. The findings also highlighted the importance to patients of stress management, the need for which had been underestimated by the researchers. The qualitative evaluation provided depth of detail not found in evaluation questionnaires. It highlighted how the intervention needed to be more practical by minimising administration, integrating role plays into behaviour change training, providing more practical information about stress management and removing self-monitoring of lifestyle change.

Conclusion: Qualitative research is integral to developing the design detail of a complex intervention and tailoring its components to address individuals' needs in different healthcare systems. The findings highlight how qualitative research may be a valuable component of the preparation for complex interventions and their evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pressure drop data are reported for two phase air-water flow through a vertical to horizontal 90° elbow bend set in 0.026 m i.d. pipe. The pressure drop in the vertical inlet tangent showed some significant differences to that found for straight vertical pipe. This was caused by the elbow bend partially choking the inflow resulting in a build-up of pressure and liquid in the vertical inlet riser and differences in the structure of the flow regimes when compared to the straight vertical pipe. The horizontal outlet tangent by contrast gave data in general agreement with literature even to exhibiting a drag reduction region at low liquid rates and gas velocities between 1 and 2 m s -1. The elbow bend pressure drop was best correlated in terms of le/d determined using the actual pressure loss in the inlet vertical riser. The data showed a general increase with fluid rates that tapered off at high fluid rates and exhibited a negative pressure region at low rates. The latter was attributed to the flow being smoothly accommodated by the bend when it passed from slug flow in the riser to smooth stratified flow in the outlet tangent. A general correlation was presented for the elbow bend pressure drop in terms of total Reynolds numbers. A modified Lockhart-Martinelli model gave prediction of the data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new universal flow map has been developed for two-phase co-current flow. The map has been successfully tested against wide variety of data. Flow regime transition predictors suggested by other authors have been shown to be useful. New transitional models are proposed for the stratified to annular regimes, blow through slug and intermittent regimes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Curie-Weiss plots of reciprocal dielectric constant versus temperature, in Ba0.5Sr0.5TiO3 films grown onto SrRuO3 lower electrodes by pulsed-laser deposition, show two minima below film thicknesses of 280 nm. This double minima implies possible mixed phases in the thin films. A graphical plot of capacitance for decreasing dc voltage versus that of increasing dc voltage shows a well-defined triangular shape for both Pb(Zr0.4Ti0.6)O-3 and SrBi2Ta2O9 thin films. However, for a 175-nm-thick Ba0.5Sr0.5TiO3 thin film, the plot shows an overlapping of two triangles, suggesting mixed phases. This graphical method appears to be effective in detecting structural subtleties in ferroelectric capacitors.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary hydrodynamics has three considerable distinctions from macrosystems: first, there is an increase in the ratio of the surface area of the phases to the volume that they occupy; second, a flow is characterized by small Reynolds numbers at which viscous forces predominate over inertial forces; and third, the microroughness and wettability of the wall of the channel exert a considerable influence on the flow pattern. In view of these differences, the correlations used for tubes with a larger diameter cannot be used to calculate the boundaries of the transitions between different flow regimes in microchannels. In the present review, an analysis of published data on a gas-liquid two-phase flow in capillaries of various shapes is given, which makes it possible to systematize the collected body of information. The specific features of the geometry of a mixer and an inlet section, the hydraulic diameter of a capillary, and the surface tension of a liquid exert the strongest influence on the position of the boundaries of two-phase flow regimes. Under conditions of the constant geometry of the mixer, the best agreement in the position of the boundaries of the transitions between different hydrodynamic regimes in capillaries is observed during the construction of maps of the regimes with the use of the Weber numbers for a gas and a liquid as coordinate axes.