51 resultados para Anterior segment

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To describe and evaluate a new method for measuring anterior chamber volume (ACV). DESIGN: Observational case series. METHODS: The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. RESULTS: Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. CONCLUSIONS: The ACV values obtained by this method were repeatable and in accord with clinical observation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To clarify the risk parameters measured by anterior segment optical coherence tomography (AS-OCT) for elevated intraocular pressures (IOP) provoked by the darkroom test and to provide recommendations for its clinical usage. METHODS: Subjects aged >40 years and whose peripheral anterior chambers were ≤1/4 corneal thickness were recruited. The anterior segment of the eye was imaged in sitting position and under both light and dark conditions and biometry was performed using anterior segment optical coherence tomography. The analyzed parameters were: (1) central anterior chamber depth (ACD); (2) anterior chamber width; (3) pupil diameter; (4) iris curvature; (5) lens thickness; and (6) number of meridians with closed angles (NCA). Then the darkroom test was performed and a positive provocative test result was defined as a rise in IOP ≥8 mm Hg after the test. Statistical analyses included: (1) the difference in parameters between positive and negative eyes; (2) the association between posttest IOP and the parameters; and (3) the difference in parameters between the 2 eyes in subjects with the asymmetric results. RESULTS: A total of 70 subjects were recruited. ACD (P=0.022), NCA in light (P<0.001), and NCA in dark (P<0.001) were different significantly between eyes with positive and negative results. There was a strong association between NCA in dark (r=0.755, P<0.001) and the posttest IOP. Among subjects with asymmetric results between the 2 eyes, the ACD was shallower and the lens thickness was larger in the positive eye. CONCLUSIONS: The posttest IOP is determined by the extent of functionally closed angles in the dark. The test may be useful in the early diagnosis of primary angle closure. At the same time, angle configuration should be evaluated to remove false positive result.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS: 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadrants during dark room gonioscopy) in each group, were consecutively enrolled. One eye of each subject was randomly selected for imaging in a completely darkened room. Measurements, including anterior chamber depth (ACD), scleral spur-to-scleral spur distance (anterior chamber width (ACW)), anterior chamber angle width, iris convexity and iris thickness, were compared between the groups. The associations between angle opening distance and biometric measurements were evaluated with univariate and multivariate regression analyses. RESULTS: There were no differences in age, axial length, anterior chamber angle measurements, pupil diameter and iris convexity between Chinese and Caucasians in both open-angle and narrow-angle groups. However, the ACD and ACW were smaller and the iris was thicker in Chinese. In the multivariate analysis, the ACD was the most influential biometric parameter for angle opening distance in both Chinese and Caucasians. After adjusting the effects of axial length, age and sex, ACD and ACW were significantly smaller in Chinese. CONCLUSIONS: Chinese eyes had smaller ACD, smaller ACW and greater iris thickness than Caucasians. ACD was the most influential parameter in determining the angle width in both ethnic groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate the agreement between optical low-coherence reflectometry (OLCR) and anterior segment optical coherence tomography (AS-OCT) for biometry of the anterior segment. SETTING: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Evaluation of diagnostic technology. METHODS: A series of OLCR (Lenstar LS 900) and AS-OCT measurements of the anterior segment were taken for consecutive subjects aged 35 years and older in a population-based study. The differences and correlations between the 2 methods of ocular biometry were assessed. Agreement was calculated as the 95% limits of agreement (LoA). RESULTS: The mean age of the 776 subjects was 55.2 years ± 12.0 (SD); 54.6% were women. The mean central corneal thickness (CCT) was smaller with OLCR than with AS-OCT (537.84 ± 31.46 μm versus 559.39 ± 32.02 μm) as was anterior chamber depth (ACD) (2.60 ± 0.37 mm versus 2.72 ± 0.37 mm) and anterior chamber width (ACW) (11.76 ± 0.47 mm versus 12.04 ± 0.55 mm) (all P<.001). The 95% LoA between the 2 instruments were -44.80 to 1.71 μm for CCT, -0.17 to -0.06 mm for ACD, and -1.28 to 0.72 mm for ACW. CONCLUSION: Optical low-coherence reflectometry and AS-OCT yielded potentially interchangeable ACD measurements, while the CCT and ACW measurements acquired by the 2 devices showed clinically significant differences.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND:

The prevalence of angle-closure glaucoma (ACG) is greater for Eskimos/Inuit than it is for any other ethnic group in the world. Although it has been suggested that this prevalence may be due to a population tendency toward shallower anterior chamber angles, available evidence for other populations such as Chinese with high rates of ACG has not consistently demonstrated such a tendency.

METHODS:

A reticule, slit-lamp, and standard Goldmann one-mirror goniolens were used to make measurements in the anterior chamber (AC) angle according to a previously reported protocol for biometric gonioscopy (BG) (Ophthalmology 1999;106:2161-7). Measurements were made in all four quadrants of one eye among 133 phakic Alaskan Eskimos aged 40 years and older. Automatic refraction, dilated examination of the anterior segment and optic nerve, and A-scan measurements of AC depth, lens thickness, and axial length were also carried out for all subjects.

RESULTS:

Both central and peripheral AC measurements for the Eskimo subjects were significantly lower than those previously reported by us for Chinese, blacks, and whites under the identical protocol. Eskimos also seemed to have somewhat more hyperopia. There were no differences in biometric measurements between men and women in this Eskimo population. Angle measurements by BG seemed to decline more rapidly over life among Eskimos and Chinese than blacks or whites. Although there was a significant apparent decrease in AC depth, increase in lens thickness, and increase in hyperopia with age among Eskimos, all of these trends seemed to reverse in the seventh decade and beyond.

CONCLUSIONS:

Eskimos do seem to have shallower ACs than do other racial groups. Measurements of the AC angle seem to decline more rapidly over life among Eskimos than among blacks or whites, a phenomenon also observed by us among Chinese, another group with high ACG prevalence. This apparent more rapid decline may be due to a cohort effect with higher prevalence of myopia and resulting wider angles among younger Eskimos and Chinese.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To describe a new surgical approach in the management of pseudophakic malignant glaucoma. Design: Noncomparative case series. Participants: Five consecutive patients with pseudophakic malignant glaucoma. Methods: All patients underwent zonulo-hyaloido-vitrectomy. The procedure involves the performance of zonulectomy, hyaloidectomy, and anterior vitrectomy (zonulo-hyaloido-vitrectomy) through a peripheral iridectomy or iridotomy via the anterior chamber. Main Outcome Measures: Medications, visual acuity, intraocular pressure, and anterior and posterior segment findings were recorded before and after surgery. Results: Resolution of the malignant glaucoma was achieved in all cases. No recurrences were observed after a median follow-up of 5.5 months (range, 1-9 months). In one patient with extensive anterior synechiae, bleb failure occurred after the resolution of the malignant glaucoma. This patient was treated successfully with a guarded filtration procedure supplemented with 5-fluorouracil. No other complications were observed. Conclusions: Zonulo-hyaloido-vitrectomy via the anterior segment appears to be an alternative option in the treatment of patients with pseudophakic malignant glaucoma. © 2001 by the American Academy of Ophthalmology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE. To describe a new model of posterior capsule opacification (PCO) in rodents METHODS. An extracapsular lens extraction (ECLE), by continuous curvilinear capsulorrhexis and hydrodissection, was performed in 42 consecutive Brown Norway rats. Animals were killed at 0, 6, and 24 hours and 3, 7, and 14 days after surgery. Eyes were enucleated and processed for light microscopy and immunohistochemistry. RESULTS. In 34 (81%) of the animals the operated eye appeared well healed before death, with a clear cornea and a well-formed anterior chamber. In eight (19%) there was no view of anterior segment structures because of hyphema, fibrin, or corneal opacification. PCO was clinically evident 3 days after ECLE and was present in all animals at 2 weeks. Immediately after ECLE, lens epithelial cells (LECs) were present in the inner surface of the anterior capsule and lens bow. Twenty-four hours after surgery, LECs started to migrate toward the center of the posterior capsule. At 3 days, multilayered LECs, some spindle shaped, were present throughout the lens capsule. Capsular wrinkling was apparent. Lens fibers and Soemmering's ring were observed in all animals 14 days after surgery, indicating some degree of cellular differentiation. Activated macrophages were present in greater numbers at 3 and 14 days after surgery (P <0.05), when proliferation and migration of LECs appeared to be greatest, and lens fiber differentiation was evident, respectively. CONCLUSIONS. In rodents PCO occurs after ECLE and is associated with low-grade inflammation, mostly of mononuclear macrophages. Although no intraocular lens implantation was performed, this model appears to be valuable for studying the sequence of events that leads to PCO after cataract surgery and the extracellular matrix cues that promote lens fiber differentiation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Defects in renewal and repair of ocular surface as a result of limbal stem cell deficiency are now known to cause varying ocular, surface morbidity including persistent photophobia, repeated and persistent surface breakdown and overt conjunctivalisation of the cornea. Ocular conditions with abnormalities of ocular surface repair include pterygium, limbal tumours, aniridia, severe scarring following burns, cicatricial pemphigoid and Stevens-Johnson Syndrome, sequelae of mustard gas exposure and Herpes simplex epithelial disease, radiation keratopathy, contact lens induced keratopathy, neuroparalytic keratitis and drug toxicity. Restoring ocular health in these eyes has traditionally been frustrating. An understanding of these intricate cell renewal and maintenance processes has spurred the evolution in recent years of new treatment methods for several blinding diseases of the anterior segment; many more exciting modalities are in the offing. However, there is inadequate awareness among ophthalmologists about the current principles of management of ocular surface disorders. The purpose of this article is to help elucidate the important principles and current treatment methods relevant to ocular surface disorders.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To describe a case with bullous keratopathy and anterior segment inflammation associated with heavy liquids. DESIGN: Observational case report. METHODS: Review of clinical and histopathologic changes. RESULTS: A 65-year-old patient underwent a pars plana vitrectomy for a rhegmatogenous retinal detachment. Perfluorodecalin was used as a temporary retinal tamponade. After surgery, bubbles of heavy liquid were noted in the anterior chamber. Fifteen months later, severe corneal edema developed, associated with corneal vascularization and keratic precipitates. Removal of heavy liquid through a paracentesis was attempted but the cornea remained edematous, and a penetrating keratoplasty was performed. In the histopathologic examination inflammatory changes from retention of perfluorodecalin were observed. There was a decompensated cornea with florid bullous keratopathy, inflammatory infiltration with vascularization, and deposition of perfluorodecalin within keratocytes and perivascular macrophages. CONCLUSION: Presence of heavy liquids in the anterior chamber may be associated with an intense inflammatory response and corneal decompensation. © 2005 by Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Glaucoma in infants has many causes. Evaluation of the anatomy of the anterior segment of eyes with infantile glaucoma may help to determine the pathogenesis of an infant's disease and influence therapeutic decisions. Methods: Eleven eyes of six infants with glaucoma were evaluated with ultrasound biomicroscopy (UBM) to evaluate the anatomic characteristics and relationships of the anterior segment structures. Results: The anterior chamber angle, iris, lens, ciliary body, and posterior chamber angle could be imaged in detail. Elongated and anteriorly placed ciliary processes were noted in all eight eyes with trabeculodysgenesis. There were no apparent anomalies in the trabecular meshwork, or anterior chamber. In three eyes with dense corneal opacities, ultrasound biomicroscopy showed severe anterior segment disorganization and thin central corneas with posterior corneal excavation. Conclusions: Ultrasound biomicroscopy is a useful non-invasive method for evaluating infants with glaucoma in cases with corneal opacities. This information can help in surgical planning for glaucoma management.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Cases of angle-closure glaucoma in patients with familial exudative vitreoretinopathy have been reported secondary to neovascularization of the anterior segment. Cases secondary to nonneovascular mechanisms have not been previously reported. Methods: Two cases are presented of angle-closure glaucoma as a result of a nonneovascular mechanism. Results: Neovascularization was found to be a very unlikely explanation for the angle closure in these two cases. Conclusion: There may be an association between familial exudative vitreoretinopathy and angle-closure glaucoma as a direct result of a retrolental process or more likely a relative lens-iris pupillary block with a large lens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Importance: This article provides, to our knowledge, the first longitudinal population-based data on refractive error (RE) in Chinese persons.

Objective: To study cohort effects and changes associated with aging in REs among Chinese adults.

Design, Setting, and Participants: A 2-year, longitudinal population-based cohort study was conducted in southern China. Participants, identified using cluster random sampling, included residents of Yuexiu District, Guangzhou, China, aged 35 years or older who had undergone no previous eye surgery.

Methods: Participants underwent noncycloplegic automated refraction and keratometry in December 2008 and December 2010; in a random 50% sample of the participants, anterior segment ocular coherence tomography measurement of lens thickness, as well as measurement of axial length and anterior chamber depth by partial coherence laser interferometry, were performed.

Main Outcomes and Measures: Two-year change in spherical equivalent refraction (RE), lens thickness, axial length, and anterior chamber depth in the right eye.

Results: A total of 745 individuals underwent biometric testing in both 2008 and 2010 (2008 mean [SD] age, 52.2 [11.5] years; 53.7% women). Mean RE showed a 2-year hyperopic shift from −0.44 (2.21) to −0.31 (2.26) diopters (D) (difference, +0.13; 95% CI, 0.11 to 0.16). A consistent 2-year hyperopic shift of 0.09 to 0.22 D was observed among participants aged 35 to 64 years when stratifying by decade, suggesting that a substantial change in RE with aging may occur during this 30-year period. Cross-sectionally, RE increased only in the cohort younger than 50 years (0.11 D/y; 95% CI, 0.06 to 0.16). In the cross-sectional data, axial length decreased at −0.06 mm/y (95% CI, −0.09 to −0.04), although the 2-year change in axial length was positive and thus could not explain the cross-sectional difference. These latter results suggest a cohort effect, with greater myopia developing among younger persons.

Conclusions and Relevance: This first Chinese population-based longitudinal study of RE provides evidence for both important longitudinal aging changes and cohort effects, most notably greater myopia prevalence among younger persons.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Primary angle-closure glaucoma (PACG) is a major cause of visual morbidity in East Asia. Dark-room provocative test (DRPT) has been used to determine which narrow angles have the risk to develop angle closure. However, the accuracy of DRPT might be altered because that after emerging from the dark room, the configuration of the angle is affected by the light of the slit-lamp and the appositionally closed angle reopens. The aim of this study was to examine the pupillary diameter in different light conditions and use it as a parameter to assess the accuracy of dark-room provocative test. METHODS: Patients with suspected primary angle-closure glaucoma undergoing DRPT were recruited. The anterior chamber angle was examined by anterior segment optical coherence tomography under the following conditions: (1) in standard room illumination; (2) after short-term dark-adaptation and (3) after DRPT. Mean values of pupil size and numbers of appositionally closed angle under different conditions were compared. RESULTS: A total of 47 eyes of 47 patients were analyzed. The pupil size after DRPT was smaller than that after short-term dark-adaptation (P < 0.001) and smaller than that in standard room illumination (P = 0.026). The numbers of appositionally closed angles after short-term dark-adaptation were significantly larger than those after DRPT (P < 0.001). There was no significant difference between the numbers of appositionally closed angles in standard room illumination and after DRPT (P = 0.157). CONCLUSIONS: Constriction of pupil size immediately after prolonged dark room provocative test may lead to change in the angle configuration, which may lead to false negative results. We suggest a modified protocol of recording intraocular pressure immediately after DRPT and performing gonioscopy following short-term dark adaptation to improve the accuracy of angle closure assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lesions involving the anterior thalamic nuclei stopped immediate early gene (IEG) activity in specific regions of the rat retrosplenial cortex, even though there were no apparent cytoarchitectonic changes. Discrete anterior thalamic lesions were made either by excitotoxin (Experiment 1) or radiofrequency (Experiment 2) and, following recovery, the rats foraged in a radial-arm maze in a novel room. Measurements made 6-12 weeks postsurgery showed that, in comparison with surgical controls, the thalamic lesions produced the same, selective patterns of Fos changes irrespective of method. Granular (caudal granular cortex and rostral granular cortex), but not dysgranular (dysgranular cortex), retrosplenial cortex showed a striking loss of Fos-positive cells. While a loss of between 79 and 89% of Fos-positive cells was found in the superficial laminae, the deeper layers appeared normal. In Experiments 3 and 4, rats 9-10 months postsurgery were placed in an activity box for 30 min. Anterior thalamic lesions (Experiment 3) led to a pronounced IEG decrease of both Fos and zif268 throughout the retrosplenial cortex that now included the dysgranular area. These IEG losses were found even though the same regions appeared normal using standard histological techniques. Lesions of the postrhinal cortex (Experiment 4) did not bring about a loss of retrosplenial IEG activity even though this region is also reciprocally connected with the retrosplenial cortex. This selective effect of anterior thalamic damage upon retrosplenial activity may both amplify the disruptive effects of anterior thalamic lesions and help to explain the posterior cingulate hypoactivity found in Alzheimer's disease.