47 resultados para ASTM A285 Gr C steel

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A softened strut-and-tie macro model able to reproduce the flexural behaviour of
external beam-column joint is presented. The model is specific for concrete with hooked steel fibres (FRC) and it is designed to calculate the flexural response, as load-deflection curve, of a beam-column sub-assemblages. The model considers the presence of a constant vertical load acting on the column and of a monotonically increasing lateral force applied at the tip of the beam.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this multicentre study was to undertake a systematic comparison of face-to-face consultations and teleconsultations performed using low-cost videoconferencing equipment. One hundred and twenty-six patients were enrolled by their general practitioners across three sites. Each patient underwent a teleconsultation with a distant dermatologist followed by a traditional face-to-face consultation with a dermatologist. The main outcome measures were diagnostic concordance rates, management plans and patient and doctor satisfaction. One hundred and fifty-five diagnoses were identified by the face-to-face consultations from the sample of 126 patients. Identical diagnoses were recorded from both types of consultation in 59% of cases. Teledermatology consultations missed a secondary diagnosis in 6% of cases and were unable to make a useful diagnosis in 11% of cases. Wrong diagnoses were made by the teledermatologist in 4% of cases. Dermatologists were able to make a definitive diagnosis by face-to-face consultations in significantly more cases than by teleconsultations (P = 0.001). Where both types of consultation resulted in a single diagnosis there was a high level of agreement (kappa = 0.96, lower 95% confidence limit 0.91-1.00). Overall follow-up rates from both types of consultation were almost identical. Fifty per cent of patients seen could have been managed using a single videoconferenced teleconsultation without any requirement for further specialist intervention. Patients reported high levels of satisfaction with the teleconsultations. General practitioners reported that 75% of the teleconsultations were of educational benefit. This study illustrates the potential of telemedicine to diagnose and manage dermatology cases referred from primary care. Once the problem of image quality has been addressed, further studies will be required to investigate the cost-effectiveness of a teledermatology service and the potential consequences for the provision of dermatological services in the U.K.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

SIMP steel was newly developed as a candidate structural material for the accelerator driven subcritical system. The serious decarburization of SIMP steel because of the high Si content was used to successfully form a self-growing TiC coating on the surface, after the Ti deposition as a first step. This TiC layer can effectively protect the surface from the static liquid lead-bismuth eutectic (LBE) corrosion at 600 °C up to 2000 h in the low oxygen LBE. However, in the oxygen saturated LBE, the TiC coating is oxidized into porous TiO2 after only 500 h and fails to protect. Therefore, the self-growing TiC coating is desired only when the oxygen content of LBE is strictly controlled on a low level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The delamination or splitting of mechanical test specimens of rolled steel plate is a phenomenon that has been studied for many years. In the present study, splitting during fracture of tensile and Charpy V-notch (CVN) test specimens is examined in a high-strength low-alloy plate steel. It is shown that delamination did not occur in test specimens from plate in the as-rolled condition, but was severe in material tempered in the temperature range 500 °C to 650 °C. Minor splitting was seen after heating to 200 °C, 400 °C, and 700 °C. Samples that had been triple quenched and tempered to produce a fine equiaxed grain size also did not exhibit splitting. Microstructural and preferred orientation studies are presented and are discussed as they relate to the splitting phenomenon. It is concluded that the elongated as-rolled grains and grain boundary embrittlement resulting from precipitates (carbides and nitrides) formed during reheating were responsible for the delamination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An elegant way to prepare catalytically active microreactors is by applying a coating of zeolite crystals onto a metal microchannel structure. In this study the hydrothermal formation of ZSM-5 zeolitic coatings on AISI 316 stainless steel plates with a microchannel structure has been investigated at different synthesis mixture compositions. The procedures of coating and thermal treatment have also been optimized. Obtaining a uniform thickness of the coating within 0.5 mm wide microchannels requires a careful control of various synthesis variables. The role of these factors and the problems in the synthesis of these zeolitic coatings are discussed. In general, the synthesis is most sensitive to the H2O/Si ratio as well as to the orientation of the plates with respect to the gravity vector. Ratios of H2O/Si=130 and Si/template=13 were found to be optimal for the formation of a zeolitic film with a thickness of one crystal at a temperature of 130 degreesC and a synthesis time of about 35 h. At such conditions, ZSM-5 crystals were formed with a typical size of 1.5 mu mx1.5 mu mx1.0 mum and a very narrow (within 0.2 mum) crystal size distribution. The prepared samples proved to be active in the selective catalytic reduction (SCR) of NO with ammonia. The activity tests have been carried out in a plate-type microreactor. The microreactor shows no mass transfer limitations and a larger SCR reaction rate is observed in comparison with pelletized Ce-ZSM-5 catalysts; (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Austenitization with lower temperature and intercritical annealing were introduced in the treatment of a maraging steel with a composition of Fe–12.94Ni–1.61Al–1.01Mo–0.23Nb (wt.%). Scanning electron microscopy was employed to study the microstructure after austenitization at 950 °C and intercritical annealing, followed by aging at 485 and 600 °C. X-ray diffraction (XRD) analysis was applied to evaluate the formation of retained or reverted austenite. Thermodynamic calculation was employed to calculate equilibrium phase mole fractions. Hardness and Charpy impact toughness of the steel were measured. Intercritical annealing treatments did not result in significant increase of hardness either before or after aging. The Charpy impact toughness of the alloy in aged condition was enhanced after austenitization at 950 °C. No austenite was observed in XRD. However, suspected reverted austenite was found after austenitization at 950 °C followed by aging at 600 °C for 4 h. Relationships among heat treatment, microstructure and mechanical properties are discussed.