13 resultados para 1318
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
A split-EGFP based bimolecular fluorescence complementation (BiFC) assay has been used to detect interactions between the Saccharomyces cerevisiae cytoskeletal scaffolding protein Iqg1p and three targets: myosin essential light chain (Mlc1p), calmodulin (Cmd1p) and the small GTPase Cdc42p. The format of the BiFC assay used ensures that the proteins are expressed at wild type levels thereby avoiding artefacts due to overexpression. This is the first direct in vivo detection of these interactions; in each case, the complex is localised to discrete regions of the yeast cytoplasm. The labelling with EGFP fragments results in changes in growth kinetics, cell size and budding frequency. This is partly due to the reassembled EGFP locking the complexes into essentially permanent interactions. The consequences of this for Iqg1p interactions and BiFC assays in general are discussed. (c) 2008 International Federation for Cell Biology. Published by Elsevier Ltd. All rights reserved.
Resumo:
In drug discovery, different methods exist to create new inhibitors possessing satisfactory biological activity. The multisubstrate adduct inhibitor (MAI) approach is one of these methods, which consists of a covalent combination between analogs of the substrate and the cofactor or of the multiple substrates used by the target enzyme. Adopted as the first line of investigation for many enzymes, this method has brought insights into the enzymatic mechanism, structure, and inhibitory requirements. In this review, the MAI approach, applied to different classes of enzyme, is reported from the point of view of biological activity.
Resumo:
Mr C, a 68-year-old Chinese male with diabetes mellitus, previous stroke and ischaemic cardiomyopathy on clopidogrel, presented with haematochezia. Colonoscopy showed a sigmoid ulcer, which was treated endoscopically. Histology of the biopsy from the ulcer revealed non-specific changes. However, he presented with recurrent bleeding from this non-healing sigmoid ulcer. A review of the histologic specimen revealed CMV intranuclear inclusion bodies. He was treated with intravenous ganciclovir, with no further hematochezia.
Keywords Hematochezia, cytomegalovirus, ulcer
Resumo:
The present study has employed a combination of spectroscopic, calorimetric and computational methods to explore the binding of the three side-chained triazatruxene derivative, termed azatrux, to a human telomeric G-quadruplex sequence, under conditions of molecular crowding. The binding of azatrux to the tetramolecular parallel [d(TGGGGT)](4) quadruplex in the presence and absence of crowding conditions, was also characterized. The data indicate that azatrux binds in an end-stacking mode to the parallel G-quadruplex scaffold and highlights the key structural elements involved in the binding. The selectivity of azatrux for the human telomeric G-quadruplex relative to another biologically relevant G-quadruplex (c-Kit87up) and to duplex DNA was also investigated under molecular crowding conditions, showing that azatrux has good selectivity for the human telomeric G-quadruplex over the other investigated DNA structures. (C) 2011 Elsevier Masson SAS. All rights reserved.
Resumo:
A study was conducted to determine the feasibility of performing
Resumo:
The potentiometric and AC impedance characteristics of all solid-state sodium-selective electrodes based on planar screen-printed Ag/AgCl electrodes are described. Two solid-state designs have been investigated. The first was based on the deposition of a sodium-selective PVC membrane directly on top of a screen-printed Ag/AgCl electrode, The second design included a NaCl doped hydrogel layer, between the PVC and Ag\AgCl layers. The hydrogel provides a mechanism to relieve any blockage to charge transfer occurring when PVC membranes are used directly on top of Ag/AgCl and also improves adhesion between the two layers. Results suggest the electrodes display Fast ion exchange kinetics, low noise and drift. The performance compares favorably to that of a conventional ion-selective electrode with internal filling solution.
Resumo:
Objective Conventional surgical management of prolapsing haemorrhoids is by excisional haemorrhoidectomy. Postoperative pain has restricted the application of such procedures in the day case setting. These operations remain associated with a period of restricted activity. The use of circular stapling devices as an alternative to the excisional approach in the management of haemorrhoids has been described. This study reports our experience of stapled haemorrhoidopexy as a day case procedure.
Methods Patients with third or fourth degree haemorrhoids were eligible for the procedure. Patients were considered suitable candidates for day case surgery based on conventional parameters. Symptoms were assessed using a previously validated symptom severity rating score. Stapled haemorrhoiclopexy was carried out using a circular stapling device. Pain scores were obtained prior to discharge. Patients were admitted if pain was uncontrolled despite oral analgesia. Symptoms were re-scored at six-week follow-up.
Results Over a 70-month period 168 consecutive stapled haemorrhoidopexies were performed or directly supervised by one consultant colorectal surgeon. One hundred and ten (65%) patients were considered appropriate candidates for day case surgery by conventional criteria. Ninety-six (87.3%) patients successfully underwent stapled haemorrhoidopexyon a day case basis. Fourteen (12.7%) patients required admission on the day of surgery (5 for early Postoperative bleeding, 4 for pain necessitating continuing opiate analgesia, two for urinary retention and three for surgery performed late in the day). Six (5%) patients were re-admitted postoperatively; four for pain relief and two because of urinary retention. Of the day case patients, 91 (82.7%) and 56 (50.9%) had been seen for 6 week and 6 month review, respectively, at the time of analysis. Symptom scores were 6 (pre-operatively) vs 0 (postoperatively) (P <0.01). 76/91 (83.5%) patients reviewed at 6/52 were asymptomatic.
Conclusion Stapled haemorrhoidopexy is a safe and effective procedure that can be carried out on selected patients on a day case basis. Complications are of a similar nature to excisional haemorrhoidectomy.
Resumo:
This paper presents new results on the complexity of graph-theoretical models that represent probabilities (Bayesian networks) and that represent interval and set valued probabilities (credal networks). We define a new class of networks with bounded width, and introduce a new decision problem for Bayesian networks, the maximin a posteriori. We present new links between the Bayesian and credal networks, and present new results both for Bayesian networks (most probable explanation with observations, maximin a posteriori) and for credal networks (bounds on probabilities a posteriori, most probable explanation with and without observations, maximum a posteriori).
Resumo:
This paper highlights for the first time a full comprehension of the deformation procedure during the injection stretch blow moulding (ISBM) process of poly(ethylene terephthalate) (PET) containers, namely thin-walled rigid bottles. The processes required to form PET bottles are complicated and extensive; any development in understanding the nature of material deformation can potentially improve the bottle optimisation process. Removing the bottle mould and performing free-stretch-blow (FSB) experiments revealed insight into the bottle forming characteristics at various preform temperatures and blowing rates. Process outputs cavity pressure and stretch-rod force were recorded using at instrumented stretch-rod and preform surface strain mapping was determined using a combination of a unique patterning procedure and high speed stereoscopic digital image correlation. The unprecedented experimental analysis reveals that the deformation behaviour varies considerably with contrasting process input parameters. Investigation into the effect on deformation mode, strain rate and final bottle shape provide a basis for full understanding of the process optimisation and therefore how the process inputs may aid development of the preferred optimised container.