136 resultados para tensionless vaginal tape
Resumo:
Vaccine-mediated prevention of primary HIV-1 infection at the heterosexual mucosal portal of entry may be facilitated by highly optimised formulations or drug delivery devices for intravaginal (i.vag) immunization. Previously we described hydroxyethylcellulose (HEC)-based rheologically structured gel vehicles (RSVs) for vaginal immunization of an HIV-1 vaccine candidate, a soluble recombinant trimeric HIV-1 clade-C envelope glycoprotein designated CN54gp140. Here we investigated the efficacy of lyophilized solid dosage formulations (LSDFs) for prolonging antigen stability and as i.vag delivery modalities. LSDFs were designed and developed that upon i.vag administration they would reconstitute with the imbibing of vaginal fluid to mucoadhesive, site-retentive semi-solids. Mice were immunized with lyophilized equivalents of (i) RSVs, (ii) modified versions of the RSVs more suited to lyophilization (sodium carboxymethyl cellulose (NaCMC)-based gels) and (iii) Carbopol® gel, all containing CN54gp140. NaCMC-based LSDFs provided significantly enhanced antigen stability compared to aqueous-based RSVs. Rheological analysis indicated the NaCMC-based LSDFs would offer enhanced vaginal retention in woman compared to more conventional vaginal gel formulations. All LSDFs were well tolerated in the mouse model. Following i.vag administration, all LSDFs boosted systemic CN54gp140-specific antibody responses in sub-cutaneously primed mice. Induction of CN54gp140-specific antibody responses in the female genital tract was evident. Of all the LSDFs the fastest releasing which was lyophilized Carbopol® gel elicited immune responses comparable to buffer instillation of antigen suggesting that rather than slower sustained release, initial high burst release from the LSDFs may suffice. The boosting of specific immune responses upon i.vag administration indicates that LSDFs are viable mucosal vaccine delivery modalities promoting antigen stability and facilitating intimate exposure of CN54gp140 to the mucosal-associated lymphoid tissue of the female genital tract.
Resumo:
UC781 is a potent and poorly water-soluble nonnucleoside reverse transcriptase inhibitor being investi- gated as a potential microbicide for preventing sexual transmission of HIV-1. This study was designed to evaluate the in vivo release and pharmacokinetics of UC781 delivered from matrix-type intravaginal ring segments in rabbits. Three polymer matrices (polyurethane, ethylene vinyl acetate copolymer, and silicone elastomer) and two drug loadings (5 and 15 mg/segment) were evaluated in at least one of two independent studies for up to 28 days in vivo. Inter-study comparison of in vivo release, vaginal tissue, and plasma concentrations for similar formulations demonstrated good reproducibility of the animal model. Mean estimates for a 28-day in vivo release ranged from 0.35 to 3.17 mg UC781 per segment. Mean proximal vaginal tissue levels (adjacent to the IVR segment) were 8– 410 ng/g and did not change significantly with time for most formulations. Distal vaginal tissue levels of UC781 were 6- to 49-fold lower than proximal tissue levels. Mean UC781 plasma levels were low for all formulations, at 0.09–0.58 ng/mL. All formulations resulted in similar UC781 concentrations in vaginal tissue and plasma, except the low loading polyurethane group which provided significantly lower levels. Loading dependent release and pharmacokinetics were only clearly observed for the polyurethane matrix. Based on these results, intravaginal ring segments loaded with UC781 led to vaginal tissue concen- trations ranging from below to approximately two orders of magnitude higher than UC781’s EC50 under in vitro conditions (2.8 ng/mL), with little influence by polymer matrix or UC781 loading. Moreover, these findings support the use of rabbit vaginal pharmacokinetic studies in preclinical testing of microbicide intravaginal rings.
Resumo:
There is an urgent global need for preventative strategies against HIV-1 infections. Llama heavy-chain antibody fragments (VHH) are a class of molecules recently described as potent cross-clade HIV-1 entry inhibitors. We studied the potential of a VHH-based microbicide in an application-oriented fashion. We show that VHH can be inexpensively produced in high amounts in the GRAS organism S. cerevisiae, resulting in very pure, and endotoxin free product. VHH are very stable under conditions they might encounter during transport, storage or use by women. We developed active formulations of VHH in aqueous gel and compressed and lyophilized tablets for controlled release from an intra vaginal device. The release profile of the VHH from e.g. a vaginal ring suggests sufficient bioavailability and protective concentration of the molecule at the mucosal site at the moment of the infection. The ex vivo penetration kinetics through human tissues show that the VHH diffuse into the mucosal layer and open the possibility to create a second defense layer either by blocking the HIV receptor binding sites or by blocking the receptors of immune cells in the mucosa. In conclusion, our data show that VHH have
Resumo:
The paper focuses on the ways in which medical discourses of HIV transmission risk, personal bodily meanings and reproductive decision-making are re-negotiated within the context of sero-different relationships, in which one partner is known to be HIV-positive. Eighteen in-depth interviews were conducted with 10 individuals in Northern Ireland during 2008–2009. Drawing on an embodied sociological approach, the findings show that physical pleasure, love, commitment, a desire to conceive without medical interventions and a dislike of condoms within regular ongoing relationships, shaped individuals' sense of biological risk. In addition, the subjective logic that a partner had not previously become infected through unprotected sex prior to knowledge of HIV status and the added security of an undetectable viral load significantly impacted upon women's and, especially, men's decisions to have unprotected sex in order to conceive. The findings speak to the importance of reframing public health campaigns and clinical counselling discourses on HIV risk transmission to acknowledge how couples negotiate this risk, alongside pleasure and commitment within ongoing relationships.
Resumo:
Objectives This study describes the in-situ gelling of econazole nitrate containing thermosensitive polymers composed of poloxamer 407 and 188 as a novel treatment platform for vaginal candidiasis.
Resumo:
Mucosally-administered vaccine strategies are widely investigated as a promising means of preventing HIV infection. This study describes the development of liposomal gel formulations, and novel lyophilised variants, comprising HIV-1 envelope glycoprotein, CN54gp140, encapsulated within neutral, positively charged or negatively charged liposomes. The CN54gp140 liposomes were evaluated for mean vesicle diameter, polydispersity, morphology, zeta potential and antigen encapsulation efficiency before being incorporated into hydroxyethyl cellulose (HEC) aqueous gel and subsequently lyophilised to produce a rod-shaped solid dosage form for practical vaginal application. The lyophilised liposome-HEC rods were evaluated for moisture content and redispersibility in simulated vaginal fluid. Since these rods are designed to revert to gel form following intravaginal application, mucoadhesive, mechanical (compressibility and hardness) and rheological properties of the reformed gels were evaluated. The liposomes exhibited good encapsulation efficiency and the gels demonstrated suitable mucoadhesive strength. The freeze-dried liposome-HEC formulations represent a novel formulation strategy that could offer potential as stable and practical dosage form.
Resumo:
Objectives: To investigate the pharmacokinetics (PK) of maraviroc, a CCR5-targeted HIV-1 entry inhibitor, in rhesus macaques following vaginal administration of various maraviroc-loaded aqueous hydroxyethylcellulose (HEC) gels, and to correlate the PK data with efficacy in a single high-dose vaginal SHIV-162P3 challenge model.
Methods: Maraviroc concentrations in vaginal fluid (Weck-Cel® sponge), vaginal tissue (punch biopsy) and plasma were assessed over 72 h following single dose vaginal application of various maraviroc-loaded HEC gels. The range of maraviroc gel concentrations was sufficiently broad (0.003 – 3.3% w/w) such that test gels included both fully solubilised and predominantly dispersed formulations. The efficacy of the HEC gels against a single high dose vaginal SHIV-162P3 challenge was also measured, and correlated with the PK concentrations.
Results: Maraviroc concentrations in vaginal fluid (range 104 – 107 ng/mL), vaginal tissue (100-1200 ng/g) and plasma (< 102 ng/mL) were highly dependent on maraviroc gel loading, irrespective of the form of the maraviroc component within the gel (solubilised vs. dispersed). Fluid and plasma concentrations were generally highest 0.5 or 2 h after gel application, before declining steadily out to 72 h. Maraviroc concentrations in the various biological compartments correlated strongly with the extent of protection against vaginal SHIV-162P3 challenge. Complete protection was achieved with a 3.3% w/w maraviroc gel.
Conclusions: A high degree of correlation between PK and efficacy was observed. Based on the data obtained with the 3.3% w/w maraviroc gel, maintenance of vaginal fluid and tissue levels in the order of 107 ng/mL and 103 ng/g, respectively, are required for complete protection with this compound.
Resumo:
Background: There is considerable interest in developing new multipurpose prevention technologies to address women's reproductive health needs. This study describes an innovative barrier contraceptive device--based on the SILCS diaphragm--that also provides long-term controlled release of the lead candidate anti-HIV microbicide dapivirine.
Study design: Diaphragm devices comprising various dapivirine-loaded polymer spring cores overmolded with a nonmedicated silicone elastomer sheath were fabricated by injection molding processes. In vitro release testing, thermal analysis and mechanical characterization were performed on the devices.
Results: A diaphragm device containing a polyoxymethylene spring core loaded with 10% w/w dapivirine provided continuous and controlled release of dapivirine over a 6-month period, with a mean in vitro daily release rate of 174 mcg/day. The mechanical properties of the new diaphragm were closely matched to the SILCS diaphragm.
Conclusions: The study demonstrates proof of concept for a dapivirine-releasing diaphragm with daily release quantities potentially capable of preventing HIV transmission. In discontinuous clinical use, release of dapivirine may be readily extended over 1 or more years. © 2013 Elsevier Inc. All rights reserved.
Resumo:
The present invention provides improved intravaginal drug delivery devices, i.e., intravaginal rings, useful for the prophylactic administration of an antimicrobial compound, e.g., Dapivirine, to a human. The intravaginal rings of the invention address previous stability issues by utilizing a platinum catalyst (e.g., in the form of a platinum-siloxane complex) for the cross-linking reaction. The vaginal rings surprisingly achieve relatively high and steady release rates in vivo with a matrix ring containing a relatively small loading dose. While the matrix rings of the present invention have in vivo the steady release rates associated with reservoir rings, they are easier and less expensive to manufacture. The present invention also provides methods of blocking DNA polymerization by an HIV reverse transcriptase enzyme, methods of preventing HIV infection in a female human, methods of treating HIV infection in a female human, and methods of preparing platinum-catalyzed intravaginal rings.
Resumo:
Background: Small molecule inhibitors of the zinc finger domain (ZFI) in the nucleocapsid protein (NCp7) of HIV-1 are potent inhibitors of HIV and SIV
replication and may have utility as topical products to prevent infection. Furthermore, intravaginal rings (IVRs) were developed as coitally-independent,
sustained release devices which could be used for administration of HIV microbicides. The aims of these studies were to demonstrate that IVRs sized for
macaques are practical and compatible with the current generation of thioester-based NCp7 inhibitors.
Methods: Non-medicated silicone elastomer vaginal rings of various sizes thought to be applicable for macaques were prepared and tested for vaginal fit in Pigtailed and Chinese Rhesus macaques. Macaques were monitored for 8 weeks for mucosal disruption by colposcopy and proinflammatory cytokine markers in cervical vaginal lavages (CVL) using Luminex bead-based technology. Three different ZFIs (compounds 52, 89 and 122, each derived from an N-substituted S-acyl-2-mercaptobenzamide thioester scaffold) were loaded at 50 mg into an optimal matrix-type ring design. In vitro continuous release studies were then conducted over 28 days and analyzed by HPLC. Rate of release was determined by linear regression analysis.
Results: Qualitative evaluation at the time of ring insertion suggested that the 25 mm ring provided optimal fit in both macaque species. All rings remained in
place during the study period (2 to 4 weeks), and the animals did not attempt to remove the rings. No tissue irritation was observed, and no signs of physical
discomfort were noted. Also, no significant induction of cervicovaginal proinflammatory markers was observed during the 8-week period during and following ring insertion. One Pigtailed macaque showed elevated IL-8 levels in the CVL during the period when the ring was in place; however, these levels were comparable to those observed in two control macaques. In vitro release of the ZFIs peaked at day 1 and then continually declined to near steady-state rates between 20-30 mcg/day. The percent release after 14 days was 2.9, 2.0 and 0.9 for ZFI 89, 52 and 122, respectively.
Conclusions: IVRs of 25mm diameter, determined to be the optimal size for macaques, were well tolerated and did not induce inflammation. Release of all ZFI compounds followed t 0.5 kinetics. These findings suggest that efficacy testing in primate models is warranted to fully evaluate the potential to prevent
transmission.
Resumo:
A very high-quality sub-band ADPCM music coding scheme which compresses high-fidelity music signals, bandlimited to 15kHz, to an equivalent PCM representation of only 4 bits per sample, is described. By processing music sampled at 32 kHz, this coder exhibits a total bit rate of only 128kbit/s and is consequently applicable to the ISDN. Subjective tests conducted with this coder have shown that music recovered from the compression scheme is essentially indistinguishable from the original material. The results obtained are of major importance, not only for ISDN and broadcasting, but also for other digital audio technology such as compact disc (CD) and digital audio tape.
Resumo:
This study explored the experiences of palliative care that bereaved carers had while providing care to a dying loved one with chronic obstructive pulmonary disease (COPD).
Method: Semi-structured interviews were undertaken with nine carers whohad lost a loved one in the preceding 6 to 24 months.These interviews explored levels of satisfaction with disease management, symptom management, and end-of-life care. With permission, interviews were tape recorded, transcribed, and subjected to content analysis.
Findings: Three themes emerged from the data: the impact of the caring experience, the lack of support services, and end-of-life and bereavement support. Carers experienced carer burden, lack of access to support services, a need for palliative care, and bereavement support.
Conclusion: The findings provide a first insight into the experiences of carers of patients with advanced COPD. Bereaved carers of patients who had suffered advanced COPD reported that they had received inadequate support and had a range of unmet palliative care needs. Special attention should be paid to educating and supporting carers during their caring and bereavement periods to ensure that their quality of life is maintained or enhanced
Resumo:
Background: Combination drug products can display thermal behaviour that is more complex than for the corresponding single drug products. For example, the contraceptive vaginal ring (VR) Nuvaring contains a eutectic (lowest melting) composition of etonogestrel (ETN) and ethinyl estradiol. Here we report the predisposition of dapivirine (DPV) to form reduced melting/eutectic mixtures when combined with other contraceptive hormones and antiretrovirals, and discuss the implications for development of combination microbicide and multipurpose prevention technology (MPT) products.
Methods: Binary mixtures of DPV with darunavir (DRV), levonorgestrel (LNG), ETN or maraviroc (MVC) were prepared either by physical mixing or by solvent evaporation. Selected binary mixtures were also incorporated into silicone elastomer (SE) VR devices. Thermal behavior of the mixtures was analyzed using differential scanning calorimetry (DSC) operating in standard heating ramp mode (10 °C/min). DSC data were used to construct two component phase diagrams for each binary system.
Results: Drug mixtures typically showed reduced melting transitions for both drug components, with clear evidence for a eutectic mixture at a well-defined intermediate composition. Eutectic temperatures and compositions for the various mixtures were: 40% DPV / 60% ETN - 170°C; 25% DPV / 75% MVC - 172°C; 65% DPV / 35% LNG - 192°C. In each case, the eutectic composition was also detected when the drug mixtures were incorporated into SE VRs. For the DPV/DRV system, the thermal behaviour is complicated by desolvation from the darunavir ethanolate polymorph.
Conclusions: When DPV is combined with small molecular weight hydrophobic drugs, the melting temperature for both drugs is typically reduced to a degree dependent on the composition of the mixture. At specified compositions, a low melting eutectic system results. The formation of eutectic behavior in binary drug systems needs to be carefully characterised in order to define product performance and drug release.
Resumo:
The 2010 Eyjafjallajökull lasted 39 days and had 4 different phases, of which the first and third (14–18 April and 5–6 May) were most intense. Most of this period was dominated by winds with a northerly component that carried tephra toward Europe, where it was deposited in a number of locations and was sampled by rain gauges or buckets, surface swabs, sticky-tape samples and air filtering. In the UK, tephra was collected from each of the Phases 1–3 with a combined range of latitudes spanning the length of the country. The modal grain size of tephra in the rain gauge samples was 25 um, but the largest grains were 100 um in diameter and highly vesicular. The mass loading was equivalent to 8–218 shards cm2, which is comparable to tephra layers from much larger past eruptions. Falling tephra was collected on sticky tape in the English Midlands on 19, 20 and 21st April (Phase 2), and was dominated by aggregate clasts (mean diameter 85 um, component grains <10 um). SEM-EDS spectra for aggregate grains contained an extra peak for sulphur, when compared to control samples from the volcano, indicating that they were cemented by sulphur-rich minerals e.g. gypsum (CaSO4⋅H2O). Air quality monitoring stations did not record fluctuations in hourly PM10 concentrations outside the normal range of variability during the eruption, but there was a small increase in 24-hour running mean concentration from 21–24 April (Phase 2). Deposition of tephra from Phase 2 in the UK indicates that transport of tephra from Iceland is possible even for small eruption plumes given suitable wind conditions. The presence of relatively coarse grains adds uncertainty to concentration estimates from air quality sensors, which are most sensitive to grain sizes <10 um. Elsewhere, tephra was collected from roofs and vehicles in the Faroe Islands (mean grain size 40 um, but 100 um common), from rainwater in Bergen in Norway (23–91 um) and in air filters in Budapest, Hungary (2–6 um). A map is presented summarizing these and other recently published examples of distal tephra deposition from the Eyjafjallajökull eruption. It demonstrates that most tephra deposited on mainland Europe was produced in the highly explosive Phase 1 and was carried there in 2–3 days.
Resumo:
This research book covers the major aspects relating to the use of novel delivery systems in enhancing both transdermal and intradermal drug delivery. It provides a review of transdermal and intradermal drug delivery, including the history of the field and the various methods employed to produce delivery systems from different materials such as device design, construction and evaluation, so as to provide a sound background to the use of novel systems in enhanced delivery applications.
Furthermore, it presents in-depth analyses of recent developments in this exponentially growing field, with a focus on microneedle arrays, needle-free injections, nanoparticulate systems and peptide-carrier-type systems. It also covers conventional physical enhancement strategies, such as tape-stripping, sonophoresis, iontophoresis, electroporation and thermal/suction/laser ablation Discussions about the penetration of the stratum corneum by the various novel strategies highlight the importance of the application method. Comprehensive and critical reviews of transdermal and intradermal delivery research using such systems focus on the outcomes of in vivoanimal and human studies. The book includes laboratory, clinical and commercial case studies featuring safety and patient acceptability studies carried out to date, and depicts a growing area for use of these novel systems is in intradermal vaccine delivery. The final chapters review recent patents in this field and describe the work ongoing in industry.